Description
BZ100N single gas detector that can detect the concentration of CO, H2S and O2 in the ambient air. With ultra-low-consumption and lightweight design, it is the smallest detector from China, only the size of a palm. It is suitable for petroleum, chemical, metallurgy, mining, underground pipeline, tunnel and other industries.
Key Features
The smallest detector from China (palm size)
2-year disposable gas detector
Low-consumption 16-bit MCU to ensure long battery life
Wide viewing-angle graphic LCD display
Configurable high and low alarm points, two levels of alarm
Battery low voltage alert
Automatic calibration to reduce detection error
Data upload function (Bluetooth)
STEL and TWA alarms for toxic gases
Automatic self-test function after power-on
ATEX and IECEx approved
Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover, areca plate, rice
Hard and tough quality Unbreakable
Single Gas Detector A single-gas detector is a device that detects the presence of any gas within an area, usually as part of a safety system. This type of Single-Gas Detector Equipment is used to detect a gas leak and interface with a control system so a process can be automatically shut down. A gas detector can also alert operators in the vicinity of the leak, allowing them to leave the area. We supply an immense choice of gas finders and screens for various applications like oxygen, combustible gases, and carbon monoxide. The gas detector adopts an embedded MCU controller detector adopts and is easy to operate, These units can be provided with sensors to recognize the most well-known gases as well as a scope of more extraordinary gases for changing applications. VS-70 xx portable gas detector locators are additionally accessible with a PID sensor to identify the presence of volatile natural compounds and with infrared IR sensors for the estimation of CO2 and other combustible gases. FEATURES : Single gas detector individually we can provide gas detectors for the following gases: Oxygen Combustible Gases LPG Hexane Hydrogen Carbon Monoxide Hydrogen Sulphide Chlorine Sulfur Dioxide Ammonia Hydrogen Chloride Hydrogen Nitric Oxide Nitrogen Dioxide Ethylene Phosphine Phosgene Ozone And Many More
Supplier: Global natural gas, electricity, crude oil, refined products, natural gas liquids (lng/lpg), metals and agricultural commodities
Services: Trade services, freight & shipping
Description BX171 is a disposable portable single gas detector that can detect H2S, CO and O2 with small size and firm configuration. It is mainly intended for individual used to detect a confined space or the working environment where dangerous gases existed and harm to personal safety. It is normally clipped on belt, lapel or breast pocket. It can be widely used in the oil and gas industries, steelworks, chemical plant, mining,marine, power plants, sewage treatment plant, environmental protection, city construction, labs etc. Key Features ATEX approved Low power consumption Two alarm level STEL alarm, TWA alarm Visual, audible, vibrating alarm Confidence beep Low battery alert
Paraflex UNI-R Multistrand FR PVC Insulated Cu. Paraflex Multistrand FR/FRLS PVC insulated Cu. Paraflex round multicore Flexible PVC insulated Cu. Paraflex submersible (3-coreflat) and UNI-R Submersible PVC Insulated Cu. Paraflex Aluminum Unarmored, Single Core twin flat 3 core and 4 core round solid and XLPE Aluminum Twin flat (Heavy Duty) Paraflex PVX VIR Copper Cabales. Paraflex Co-Axial wires. Paraflex Oxygen Free speaker and camera wire. Paraflex twin flat and copper flexible cables. Paraflex PVC FR tape. to 630 sq.mm core, 2 core, 3 core, 3.5 core and 4 core both in Al & Cu. Under IS: 7098 (Part 1), IS: 1554 (Part 1). Aerial Bunch cable IS: 14255 range 16 sq.mm to 95 sq.mm. PVC Rigid Conduits IS 9537 Part-3, 2003
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Overview The gas relay calibrator is a tester device that specializes in verification of gas gas relays. The gas relay calibrator is a detection check device for the detection of the Vaste Relay Flow Period Value, Cable Point Value, and Sealing Pressure Value. Gas Relay Calibrator is suitable for more than 90 of Gas Relay checks in Gas relay is also known as gas gas relay, is a protective unit in an oil immersion transformer, mounted in an oil pipe under transformer oil pillow. The gas relay detector is a dedicated gas relay pressure release valve calibrator device for the gas relay value, a capacity value, and sealing pressure value, and the gas relay tester uses a microcomputer control technology, and the gas relay tester is detected by detecting a high-precision pressure sensor. When the gas relay tester simulates the internal failure of the transformer, the gas method of the gas relay tester is calculated to calculate the flow rate value to achieve the detection of gas relatives, the Gas protection action value, the gas relay calibrator adopts the fine container combined with the US MCC's micro Press the precision sensor, detect the inside of the gas relay to exclude the liquid volume method to calculate the light gas capacity value Technical parameter Portable gas relay calibrator Protection IP65 Execution standard Compliance with DL T540-1994 standards and IEC power input 50HZ 220V Flow speed detection heavy gas 0. 0.5m s 0.05m s resolution 0.01 0.52.5m s 0.1m s resolution 0.1 Maximum error 1 Volume detection light mill 0 300ml resolution 0.01ml 300ml 700ml resolution 0.1ml Maximum error 1 test method Automatic measurement, semi automatic measurement, manual measurement of three measurement methods Sealing test 0-150KPA resolution 0.1 0-300KPA resolution 1.0 Comprehensive error