Ferrite Toroid for phase shifter
Microwave ferrite(A50) for phase shifter Li Zn - Ti - Mn - (Co) Lithium - Zinc - Titanium Manganese - (Cobalt) MS(Gauss) :5000gs ±5% Tc ( °C) :450 H (Oe) 170 ±20% Hk (Oe) 3 ±5% DIELECTRIC CONSTANT 15.3 DIELECTRIC LOSS TANGENT 0.0005 Br (Gauss) 3300
CIRCULLATION FAN Air cooling fans are used for maintaining good air circulation and temperature in poultry farms. Our 36 air circulating fans can be used for various applications, like poultry farms, industrial buildings etc., and providing high efficiency. These fans are available in both single phase and three phase motor option. 1.Grills are plastic coated and thick diameter wire gauge (2.5mm) is used, and the gap is maintained 15mm as per international quality standards to avoid human accidents and rate entering into the fan. 2. The blades are made of compounded plastic so less chances of bending and hence less breaking chances. 3. Motor is efficient and complete thermal protection and moisture proof. 4. The CFM of fan 13000 and minimum airflow of 8.5 meters/sec. 5. Minimum positive air throws of 50ft. When we say 50 Length in practically. 6. Easy installation &Zero Maintenance
Microwave ferrite(Grade:A50 ) for X-Band high power ferrite phase shifter
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Electricity System SPD, M-GDT, MOV, Signal System SPD Feeder System SPD
Follow Current turn-off metal-ceramic GDT Two-electrode metal-ceramic GDT Three-electrode metal-ceramic GDT SMT metal-ceramic GDT
Supplier: Ndfeb magnet, magnetic assembly, ferrite magnets, smco, halbach array magnet, surge protection device, gas discharge tube, lightning protection earthing system, spd, gdt, arrester, surge, lightning