Pedestal fans are designed to place on the shop floors. The cast aluminium alloy, statically and dynamically balanced impeller of high efficiency aerofoil section blades is mounted directly on the motor shaft with suitable, sturdy protection guards and mounted on the steel pipe with motor base plate. The Wall Mounting Fans are suitable for mounting at higher elevation in the wall or stanchion to avoid the occupation of door space. These fans are mounted on steel pipe with suitable holes in the base plates for heavy duty Motors.
We ensure to provide clients with the best range of Air Circulating Fan. These Air Circulating Fans have non corrosive housing and based on advanced working principle. The Air Circulating Fan that we offer ensures efficient performance for longer time.
* Highlights:
- Longer service life
- Non-corrosive housing
- Cost effective
- Low noise operations
Hot air oven dryer works with hot air circulation method, adopts electric heating or steam heating. The heating system provides hot air, and the ventilation and dehumidification system circulates the hot air to discharge the moisture in the room according to the process requirements, while supplementing with fresh air. â?? The automatic control system can control the heating, cooling, and dehumidification operations of the drying process according to the set drying process. The hot air dryer is equipped with one and more mobile trolleys and baking trays inside. Heating type:Electric,steam.â?? Classified with trays: 24,48,96,144,192trays. Hot Air Oven Dryer Model:VG-HG24 Size:1600*1200*2350mm Heating type:Electricity Main material:Stainless steel Power:13kw Trays:24pcs Tray size:640*460*45mm Temperature:Adjustable Voltage:380V/50HZ or others Warranty:One year After sales service:Video and online meeting
We offer Portable Dehumidifier or De-humidifier, Industrial dehumidifier, swimming pool dehumidifier, commercial Dehumidifier, heavy duty dehumidifier, Pool Dehumidifier, desiccant dehumidifier for applications such as Home, Indoor Swimming pool, Spa, Server Room, Library, Laboratory, Museums, warehouse and Industrial Applications. We are dehumidifier supplier in Dubai, Abu Dhabi, Sharjah, Oman, Doha Qatar, Saudi Arabia, Kuwait & UAE. Portable Dehumidifier has following features: 1. Dehumidification: 10, 20, 22, 30 L/day at ambient condition 30 degrees Celsius, 80% RH. 2. Low Power consumption 3. High Air circulation volume. 4. Petlier & Compressor type. 5. Low Noise level. 6. Option of Built in water reservoir & Continuous drainage. 7. Pre filter removes dust, eliminates larger floating pollutant particles and odor. CtrlTech, aerial, De'longhi, Novita, Bry-air, Ebac, Westinghouse, munters, calorex, Elu-klima, Fral dehumidifier, LG, General Electrical, GE dehumidifier etc. 9. Carbon filter removes the odor smell. 10. Optional permanent drain facility is available. 11. Built-in temperature sensor. 12. Working range: 5 to 35 degrees Celsius. 13. Automatic Fan defrosting function. 14. Unit size: 240mmÃ?360mmÃ?720mm , Product weight: 17kgFf 15. Safety approved: GS, LVD, EMC and CE. Air dehumidifier, Best Dehumidifier, Room Dehumidifier, Mini Dehumidifier, Small Dehumidifier, Portable dehumidifier,House dehumidifier, Quite dehumidifier, pint dehumidifier, Buy dehumidifier Dubai, Dehumidifier supplier in UAe, Dehumidifier supplier in Dubai, Dehumidifier UAE, Dehumidifier Dubai, Portable Dehumidifier Dubai.
Linear Bar Grille A linear bar grille is a type of air distribution grille that is commonly used in HVAC systems. It consists of a series of horizontal or vertical bars spaced evenly apart to allow air to pass through while providing a uniform distribution of air flow. Linear bar grilles are available in a range of sizes, finishes, and configurations, and can be customized to fit specific design requirements. Some features of linear bar grilles include: High air flow capacity: Linear bar grilles are designed to handle high air flow rates, making them ideal for use in large commercial spaces or areas where a significant amount of air circulation is required. Customizable design: Linear bar grilles can be designed to match the aesthetic of the surrounding space. They are available in a range of finishes and can be customized to fit specific design requirements. Easy installation: Linear bar grilles are relatively easy to install, and can be mounted on walls or ceilings using simple mounting hardware. Low noise level: Linear bar grilles are designed to minimize noise levels and provide a comfortable environment for occupants. Applications of linear bar grilles include: Offices: Linear bar grilles are commonly used in office buildings to provide a comfortable and consistent air flow throughout the space. Retail spaces: Linear bar grilles are often used in retail spaces to create a comfortable shopping environment for customers. Hospitals: Linear bar grilles are used in hospitals to provide a clean and sterile environment for patients and staff. Schools: Linear bar grilles are commonly used in schools to provide a comfortable and consistent air flow throughout the building.
Closed Circuit Cooling Tower Closed circuit cooling tower (also known as an evaporative air cooler or closed cooling tower) is the tubular heat exchanger placed in the tower, through the circulation of air, spray water and circulating water heat exchange to ensure the cooling effect. AUVC not only provides different shapes of cooling towers used in industries, such as round shape cooling towers and square cooling towers, but also offers closed cooling towers and open circuit cooling towers as well. The type of closed circuit cooling tower is widely used in iron and steel metallurgy, power electronics, machining, air conditioning system and other industries. How do closed circuit cooling towers work? Closed-circuit cooling towers make it possible to separate the evaporative circuit from the process circuit (customer circuit). A stainless-steel plate heat exchanger attached to the cooling tower, in its dedicated room, allows a glycol-free operation, and a simplified and unequalled ease of maintenance. The closed circuit cooling tower works as follows On the process side to be cooled (customer loop), the water to be cooled enters a plate heat exchanger connected to the tower and is cooled and discharged. The primary loop is closed and never comes into contact with air. On the secondary side of the cooling tower, the water is sucked out of the pool by a pump and circulated through a stainless steel plate heat exchanger. The water leaving the exchanger is piped to the top of the unit. This water is graded and evenly dispersed over the exchange surfaces by dispersers (also known as water distribution nozzles). Air driven by fans (axial or centrifugal) enters from the lower part of the cooling tower, is heated and saturated with water and exits from the upper part, passing between the exchange surfaces. Under the effect of the surface tension of the filler ladder, the water spreads uniformly and flows away over the entire height of the tower. The exchange surface is thus increased. The water cooled by forced ventilation falls freely into an inclined pool located at the bottom of the unit. Types of Closed Type Cooling Tower
ZL-3 model steam air heater with upper outlet and lower inlet is consists of 9 parts: steel-aluminum radiator fin tube + electric steam valve + drain valve + insulation box + fan + Fresh air damper + waste heat recovery device + dehumidification fan + electric control system. It is specially designed for supporting downflow drying room/heating rooms. After convert the outside steam heat to heat inside the insulation box through by the fin tube, it�´s mixing with recycle or fresh air, under the action of the fan, it is discharged from the upper outlet into the drying room or heating space. Then cooled air pass through the lower air outlet for secondary heating and continuous circulation. And when the humidity of circulating air reaches the emission standard, the dehumidification fan and fresh air damper will start simultaneously. The exhausted moisture and fresh air implement sufficient heat exchange in the waste heat recovery device, so the moisture is discharged and the fresh air with recovered heat enter the circulation system. Advantages/features 1. Simple structure and easy installation 2. Large air volume and small wind temperature fluctuation 3. Stainless steel electric heating finned tube, durable 4. Steel-aluminum finned tubes, high heat exchange efficiency. The base tube is made of 8163 seamless tube which is pressure-resistant and durable; 5. Electric steam valve controls the amount of inlet, automatically cuts off or opens according to the set temperature, so that can accurately controls the temperature. 6ï¼?High temperature and high humidity resistant fan with IP54 protection rating and H-class insulation rating. 7. Integrating the dehumidification and fresh air system, heat loss is extremely small through by the waste heat recovery device. 8. Automatically replenish fresh air
Air Conditioner for Passenger Car Today, vehicles have reached a high level of climate comfort and will continue to improve in the future. However, automotive air conditioners do much more than provide a comfortable driving experience. They also play a key role in safety. In addition to keeping drivers comfortable and alert, air conditioners dehumidify cabin air, which prevents windows from fogging up. Advantages A car air conditioner captures outside air, cools or heats it, and then filters it before venting it into the cabin. In addition to comfort, this process offers many other benefits. Air Conditioning and Comfort The primary function of a car's air conditioner is to ensure climate comfort by providing cooled or heated air. Efficiency Closing the windows to allow the car to circulate in the air prevents outside air from constantly entering the cabin, improving aerodynamics and reducing fuel consumption. Health Activating the air conditioning allows the driver and passengers to close the windows as it ensures a supply of filtered air and prevents pollutants from entering the cabin.
ZL-2 model steam air heater with Left-Right Circulation is consists of 7 parts: steel-aluminum radiator fin tube + electric steam valve + drain valve + insulation box + fan+ Fresh air damper + electric control system. It is specially designed to support the left and right circulation drying room. For example, the 100,000 kcal model drying room, it is equipped with 6 fans, three on the left and three on the right. When the three fans on the left rotate clockwise, the three fans on the right rotate counterclockwise in a cyclic alternating manner, forming a relay, The left and right sides serve as air inlets and outlets alternately, taking out all the heat generated by steam heater. It is equipped with an electric fresh air damper to supplement fresh air in coordination with the dehumidification system in the drying room/drying place. 1.Simple structure and easy installation 2. Large air volume and small wind temperature fluctuation 3ï¼?Steel-aluminum finned tubes, high heat exchange efficiency. The base tube is made of 8163 seamless tube which is pressure-resistant and durable; 4. Electric steam valve controls the amount of inlet, automatically cuts off or opens according to the set temperature, so that can accurately controls the temperature. 5. High-density fire-resistant rock wool insulation box to avoiding heat loss 6. High temperature and high humidity resistant fan with IP54 protection rating and H-class insulation rating. 7. left and right fans run alternately in cycles to ensure even heating 8. Automatically replenish fresh air
AIR CONDITIONER SYSTEM General model electric air conditioner. small in size and easy installation, apply to multiple types of mirco-electric cars. The air conditioning in a vehicle must cool the passenger compartment and draw moisture out of the fresh air supply. As such it provides an assurance of pleasant passenger compartment temperatures even in strong sunlight and condensation-free windows when humidity levels are high. COMPONENTS OF VEHICLE AIR CONDITIONING The most important components of Car Air Conditioning are: Compressor Capacitor Dryer Expansion valve Evaporator The individual components are interconnected via hose lines to form an enclosed system known as the refrigerant circuit. The refrigerant circulates in the refrigerant circuit. It is driven by the compressor.
Principle The principle of temperature drop: Water will absorb the heat from the hot air when steaming naturally. Its working principle: Extract wind through air blower, and the blower produces press, the air crosses the wet curtain, at the same time the water pump delivers water to the cloth water pipe on the wet curtain, and moisten the face of the whole wet curtain evenly, and the special angle of the wet curtain makes the water flow into one side where the air enters the wind directly, absorb a large amount of heat to lower the temperature through wet curtain, and filter it, which can make the wind nice, cool, moist and fresh. The water without evaporation falls back to the chassis forming waterway circulation. There are water level inductors on the chassis, when the water level lands to the fixed water level, it automatically open inlet valve to supply the source of water till the height of the booking water level, then close the inlet valve automatically. Applicable scope Manufacturing industries such as clothing , textile , the machinery , pottery , chemical industry , metallurgy , glass , five metals , leather ,etc.; Processing industry such as electroplating , electron , shoes-making , printing and dyeing , plastics , printing , packaged food; Stadium , school , waiting room , super market , laundry , kitchen , food market , underground parking , greenhouse, poultry , flowers , animal husbandry ,etc.