1) YR series three-phase asynchronous motor winding has reliable and stable insulation. Its stator adopts the structure of external pressure mounting and rotator uses the high strength, painted, flat-type copper cable. Coil is with high mechanical strength. Collector ring and carbon brush are placed outside of the end cover, which can protect the coil from the pollution of dust.
2) YR series motors have the advantages of high torque, little vibration, high frequency, low noise and reliable operation.
3) YR series motors are widely used in mining machinery, such as winch, ball mill, blowers, pumps, wire drawing machines, rolling machines and other mechanical equipment.
Technical data
Type Rated output Basic supply Duty cycle Parameters at rated output starting characteristics weight
P1 U S Nn In Cosφ Is Ms Mmax
Kw Hp V - Min-1 A - A Nm Nm Kg
2p=2
A90ll-2ksr 5.5 7.5 230/400 S6-40% 2900 15.7/9.1 0.88 23 21 28.4 25.5
A90lx-2ksr 5.5 7.5 230/400 S1 2800 19.6/11.3 0.93 53 30 38
A100lk-2ksr 5.5 7.5 230/400 S6-40% 2820 11.5/6.6 0.82 39 25 30 29.0
2p=4
A90ll-4ksr 4.2 5.6 3x400 S6-40% 1250 6.5 0.92 22 39 39.6 26.0
A100lk-4ksr 4.0 5.6 230/400 S6-40% 1350 10.6/6 0.88 22 30 34 31.0
A100lx-4ksr
A100lx-4kr 8.0 10.7 230/400 S6-40% 1350 23.4/13.5 0.85 47 70 78 39.0
A100l-4ksr
A100l-4ksrs 5.5 7.5 230/400 S6-40% 1350 16/9.3 0.86 35 52 58 35.0
A112m-4ksr 4.8 6.4 400/690 S1 1420 8/4.6 0.86 26 62 73 41.0
The electric motors can also be produced at different basic supply voltages and frequency.
Three phase asynchronous electric motor with built-in electric-magnet brake
Technical data
Type Rated
Output Basic
Supply
Voltage Duty
Cycle Parameters at
Rated output Starting
Characteristics Rated brake
(Stopping) torque Rated output of
Brake electric
Magnet Basic
Supply
Voltage of brake electric
Magnet
P1 U S Nn In Cosφ Is Ms Mmax
Kw Hp V - Min-1 A - A Nm Nm Nm - -
A90lx-2kslb 5.5 7.5 400v/50hz S1 continuous 2800 11.3 0.93 42 38 42 10 50w 98v
Vibrating motor
1. The excitation force and power are properly matched, with large vibration force, light body weight, small volume and low mechanical noise.
2. Because the vibration motor is a strong resistance vibration rather than resonance, it has a stable amplitude.
3. The vibration frequency range is large. The vibration frequency of electromagnetic vibration exciter is fixed, which is generally equal to the step rate of power supply. The vibration frequency of vibration motor can be adjusted in a wide range by adjusting the speed, and the vibration frequency and amplitude can be selected arbitrarily according to different routes.
4. Due to the small influence of power fluctuation, the electromagnetic vibration exciter will cause a large change in the excitation force due to the change of voltage, but in the vibration motor, this change is very small.
5. Multi machine combination can realize self synchronization and complete different process requirements.
â?? the direction of exciting force can be changed according to the installation mode of vibration motor.
the exciting force and amplitude can be adjusted steplessly only by adjusting the included angle of the eccentric block.
8. The maintenance is simple. Since the spring is not used like the electromagnetic type, the maintenance work such as clearance adjustment and weight adjustment can be exempted, and only the bearing needs to be repaired regularly.
it can meet the working needs of all kinds of vibrating machinery.
Y series motor is a kind of low-voltage three phase asynchronous motor, which is a basic series for general
applications.
This series can meet requirements for general application international standard with frame range 80-135.
Y series has the advantages of high efficiency, energy saving, high operational performance, small vibration,
low noise, long life, high reliability, etc.
Installation dimension and power grade completely conform to IEC standard.
It employs Grade B insulation, IP44 grade for shell protection and IC411 cooling mode.
The rated voltage and frequency of Y series are 380V, 400V, 415V, 440V, and 50Hz, 60Hz.
Y series asynchronous motor is widely applied for machinery and equipments without special requirements,
such as agricultural machinery, food machinery, fan, agitator and air compressor, etc.
For more information, please be free to conact us for detailed PDF files.
Y2 series induction motors, developed with new technology are renewal and upgraded products of Y series.
Y2 series motors are defined as totally enclosed, fan cooled, squirrel cage type and noted for ití»s design,
excellent appearance, compact structure, low noise, high efficiency, large starting torque, excellent starting
performance, easy maintenance, etc.
The motors are adopted with F class insulation and designed with assessing method for insulation system
according to international practice.
Y2 series motors are widely used in various machinery and equipments, driving equipments etc. Such as
machine tools, blower, pumps, compressors, transporters, agricultural
and food processing machinery
Work environment
Ambient temperature: -15íµ~40íµ
Altitude: Not exceed 1000 meters
Rated voltage: 380V
Rated frequency: 50Hz
Connection: Y start-connection for 3 KW and below,
Delta-connection for 3 KW or more
Duty: S1
Insulation degree: F
Cooling method: IC411
Protection: The main body of motor reach IP54; the terminal connection box reach IP55
For more information, please be free to conact us for detailed PDF files.
.
Standard package
Y2 series three phase asynchronous motors is a kind of totally enclosed fan-cooled squirrel-cage AC asynchronous motors with IP54/IP55 protection and class F insulation, its efficiency are in conformity with EFF 2 standard European. Y2 Series motors are widely used as drive mechanism of various machineries, such as pumps, compressors, machining equipments, transportation system, agricultural mechanism, food processing mechanism etc.
Frame 80 to 315, 2/4/6/8 poles, 10/12 poles for frame 280 and frame 355 on request.
8) EFF: EFF3
9) Poles: 2, 4, 6, 8
10) Cooling method: IC0141
11) Mounting types: IMB3, IMB5, IMB35, IMB34, IMB14
12) Operating mode: S1
13) Connection: "Y" type for 3kW and downwards, "D" type for 4kW and upwards
14) Ambient temperature: -15C < 40C
15) The altitude should be lower than 1, 000m above the sea level
16) Relative humidity: Not higher than 90%.