1. Principle
This test kit is based on the competitive enzyme immunoassay for the detection of Clenbuterol in the pork. The coupling antigen is pre-coated on the micro-well stripes. The Clenbuterol in the testing sample competes with the coupling antigens pre-coated on the micro-well stripes for the antibodies against Clenbuterol. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the content of Clenbuterol in it. This value is compared to the standard curve and the content of the corresponding Clenbuterol is subsequently obtained.
2. Technical specifications
Sensitivity : 0.1 ppb
Detection limit:
Tissue0.1ppb
Urine, serum0.1ppb
Feed50 ppb
Recovery rate
Urine, serum9010%
Tissue8010%
Feed8015%
Cross-reaction rate:
Clenbuterol100%
Terbutalin< 1%
Salbutamal< 19%
Ractopamine< 1%
96 well
H-fabp fast test kit (immunofluorescence assay) is intended for use together with getein1100 immunofluorescence quantitative analyzer (getein1100) or getein1600 immunofluorescence quantitative analyzer (getein1600) to quantitatively determine the concentrations of h-fabp in human serum, plasma, or whole blood specimens in point-of care and laboratory settings. H-fabp fast test kit (immunofluorescence assay) is intended for in vitro quantitative determination of heart-type fatty acid binding protein (h-fabp) in serum, plasma or whole blood. This test is used in the early diagnosis of ami and pulmonary embolism, and monitoring of chronic heart failure.
Intended use: Toxoplasma IGG/IGM rapid test is a rapid immunochromatographic test for the simultaneous detection of IGM and IGG antibodies to toxoplasma gondii in human serum/plasma. The test can be used as a screening test for toxoplasma infection and as an aid for differential diagnosis of the self limiting primary toxoplasma infections and the potentially fatal secondary toxoplasma infections in conjunction with other criteria. Test principle: The toxoplasma IGG/IGM rapid test is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) A burgundy colored conjugate pad containing toxoplasma recombinant envelope antigens conjugated with colloid gold (toxoplasma conjugates) and rabbit igg-gold conjugates, 2) A nitrocellulose membrane strip containing two test bands (t1 and t2 bands) and a control band (c band). The t1 band is pre-coated with the antibody for the detection of IGM anti-toxoplasma, t2 band is coated with antibody for the detection of igg anti-toxoplasma, and the c band is pre-coated with goat anti rabbit IGG. Absence of any t bands (t1 and t2) suggests a negative result. The test contains an internal control (c band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit igg/rabbit igg-gold conjugate regardless of the color development on any of the t bands. Otherwise, the test result is invalid and the specimen must be retested with another device. Reagents and materials supplied : 1. Test cassette individually foil pouched with a desiccant. 2. Plastic dropper 3. Buffer 4. Package insert. Storage and stability: The kit must be stored at 2-30pc. Warning and precautions: 1. For in vitro diagnostic use only. Not for medicinal use. 2. Do not use beyond expiry date. 3. Read the instructions careful y before performing the test. 4. Handle all specimen as potential y infectious. 5. Follow standard biosafety guidelines for handling and disposal of potential y infective material.
1. Principle This test kit is based on the competitive enzyme immunoassay for the detection of Florfenicol in the tissue (chicken,pork), fish, shrimp , honey. The coupling antigen is pre-coated on the micro-well stripes. The Florfenicol in the testing sample competes with the coupling antigen pre-coated on the micro-well stripes for the antibody against Florfenicol. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the testing sample has a negative correlation with the content of Florfenicol in it. This value is compared to the standard curve and the content of the corresponding Florfenicol is subsequently obtained. 2. Technical specifications Sensitivity : 0.5ppb Detection limit: Honey1.5ppb Meat,liver,shrimp ,fish0.5ppb Recovery rate Honey70%10% Meat,liver,shrimp ,fish80%10% Cross-reaction rate: Florfenicol100% Thiamphenicol¼T0.1% Chloramphenicol¼T0.1% 96 wells
We have just achieved a major breakthrough in the development of dengue igg/igm antibody early test. Our new product is capable to detect the presence of dengue igm antibody in human serum within 3-5 days since primary infection (tested and verified with reference standard blood sample from usa cdc), while similar products currently found on the market can only detect it after at least 10-15 days. The significance of this achievement is that the new dengue igg/igm antibody early test now can diagnose dengue infection at a very early stage, which previously could only be done with a dengue ns1 antigen test. Type: immunoassay system Brand name: ntbio/oem/private label Place of origin: british columbia, canada Size: 60mm x 300mm Sensitivity: 95.3% Specificity: 95.0% Specimen: whole blood/serum/plasma .
Highest accuracy Fast result interpretation Cost effective Made with best choices of materials Type: immunoassay system Brand name: ntbio/oem/private label Place of origin: british columbia, canada Size: 60mm x 300mm Sensitivity: 94.3% Specificity: >98.9% Specimen: whole blood/serum/plasma .
Highest accuracy Fast result interpretation Cost effective Made with best choices of materials Type: immunoassay system Brand name: ntbio/oem/private label Place of origin: british columbia, canada Size: 60mm x 300mm Cut-off value: 1000 ng/ml Sensitivity: 99.5% Specificity: >99.7% Specimen: urine .
Because this item is not stocked in our warehouse, processing, transit times and stock availability will vary. If you need your items by a certain date, please contact us prior to placing your order. Expedited shipping availability may vary. We cannot guarantee that this item can be canceled off of the order or returned once it is placed. Additional information Weight 0.14 lbs Quantity 50/Pack Type Water Test Strips Test Level 10 PPM (Free Chlorine) 10 PPM (Total Chlorine) 240 PPM (Total Alkalinity) 425 PPM (Total Hardness)
Supplier: Rapid antigen test kits , viral transport media ( moh approved vtm kits), rna extraction kits , cr plates and machines.
biochemistry analyser , biochemistry medias fda approved
rapid test kits hiv , hcv , filter tips, laboratory consumables , agar plates , wolf air mask (the only device globally to be tested and effective 99.9 percent against covid 19)
Services: Export
Easy-to-Read Color Chart Each strip measures concentrations between 10-200ppm (parts per million), with color matches at 10, 50, 100 and 200ppm. The distinct color chart and accurate, reproducible readings give an immediate response for quick and easy use. Meets Requirements Federal, state, and local health regulations require users of chlorine-based sanitizer solutions to have appropriate test kits available to verify the strength of sanitizer solutions. This kit meets those requirements. Easy to Use The distinct color match at each full unit makes it easy for the user to detect exhaustion of solutions that should be replaced. It also helps avoid the use of excessive amounts of sanitizing agents, to avoid wasting product! Simply remove a strip from the vial, dip the strip into the sanitizing solution, blot with paper towel, then instantly compare the resulting color with the color chart. Accurate Sanitizer solutions are essential in the food service industry. These strips ensure that those sanitizers are at the proper concentration. For accurate results, store these test strips away from areas with high humidity or where they may be exposed to water before use, as those conditions may compromise results. dditional information Weight 0.03 lbs Quantity 1/Each Type Chlorine Test Strips Package Size 100 Pieces Test Level 10 â?? 200 PPM