Operating Voltage-323v to 528v
Motor Capcity- 3.7kw to 5.5 kw
Cabient Size- 1800*400*265
Communication Mode-parallel / Serial
Characters: Radio frequency:433mhz Max controlling distances:>30m Ultra-high touch sensitive color wheel 2 audio modes 'spectrum' function 6 programmed dynamic modes 6 fixed acoustic sensitivites Acoustic sensitivity setting on the remote control Adjustable to any acoustic sensitivity(1-100%) 8-step speed/brightness control 'memory' function Independent warm white, day white, cold white color Size:14cm×5.5cm Weight:90g
1.It is made of specular stainless steel(304 in China) and semicirular arcs at corners ensures easy cleaning. 2.Microprocessor temperature controller makes temperature stability. 3.Door temperature controller prevents dewfall on glass door of incubator effectively. 4.Microorganism filter at inlet provides 100% filtrated gases. 5.Main parts are all imported,equipped with CO2 pressure releasing valve.(Special for CO2 incubator) Model HHCP-T(80L)with UV light Electrical Requirement 220V 50HZ Input Power (W) 450 Heating Method Air-jacket Temperature Range(Degree) RT+5~50 Temperature Control (Degree) 0.1 Temperature Stability(Degree) 0.3 CO2 Range 0~20% CO2 Recovery Calibration*1.2min Humidifying Method Natural Evaporization Ambient Temperature(Degree) +5~35 Cubage(L) 80L W*D*H Interior Dimension(mm) 500*400*400 W*D*H Overall Dimension(mm) 570*570*820 Shelves per Chamber 2PCS . Packing Style: Standard Export Packing Style W*D*H Packing Dimension(mm): 710*710*920 Gross Weight: 67KG Net Weight: 51.5KG.
XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automatic XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automaticpower supply :DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm temperature control: 1. Set the temperature + ?Normal display mode, long press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL means the sensor fault display HHH mean Test temperature exceeds the range of measurement
Temperature Humidity Controller XM452 power supply: DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm temperature control: 1. Set the temperature + ?Normal display mode, long-press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL mean the sensor fault display HHH mean Test temperature exceeds the range of measurement
Thermostat Detailed screw type bimetal thermostat description 1:auto reset 2:cremis shell 3.6.3*0.8 terminal 4:CQC UL VDE TUV SGS Detailed brass screw bimetal thermostat description fixation of the working temperaturing reliable snap action perdurable less radio interference Technical parameters: Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load) 2)UL AC125V 50Hz 15A (Resistance load) 2.Action temperature range: 45~160 (Optional); temperature accuracy: 3.Recovery and action temperature difference: 8~100 (Optional) 4.Connection method: Insert the terminal 250# (bending angle: 0~90deg optional); Insert the terminal 187# (bending angle: 0~90deg optional; thickness: 0.5, 0.8mm optional) 5.Lifespan: over100,000 times 6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V 7.Contact resistance: less than 50m 8.Insulation resistance: less than100M Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls; Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls. 10.Casing protective class: IP00 11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device. 12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole Structure and application: KI-32 serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state. Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat. Characteristics: Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio Precautions: 1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor. 2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation. 3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited. 4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection; 5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40. Passed certifications :CQC UL VDE TUV SGS. according to customers' requirements.
Detailed Product Description Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio Name:thermostat model:KI-31 Technical parameters: Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load) 2)UL AC125V 50Hz 15A (Resistance load) 2.Action temperature range: 45~160 (Optional); temperature accuracy: 3.Recovery and action temperature difference: 8~100 (Optional) 4.Connection method: Insert the terminal 250# (bending angle: 0~90¡ã optional); Insert the terminal 187# (bending angle: 0~90 optional; thickness: 0.5, 0.8mm optional) 5.Lifespan: 100,000 times 6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V 7.Contact resistance: 50m 8.Insulation resistance: 100m Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls. 10.Casing protective class: IP00 11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device. 12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole Structure and application: KI-31serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state. Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat. Characteristics: Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio Precautions: 1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor. 2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation. 3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited. 4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection; 5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40. Passed certifications :CQC UL VDE SGS. according to our custom.
Detailed brass screw bimetal thermostat description fixation of the working temperaturing reliable snap action perdurable less radio interference Technical parameters: Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load) 2)UL AC125V 50Hz 15A (Resistance load) 2.Action temperature range: 45~160 (Optional); temperature accuracy: 3.Recovery and action temperature difference: 8~100 (Optional) 4.Connection method: Insert the terminal 250# (bending angle: 0~90deg optional); Insert the terminal 187# (bending angle: 0~90deg optional; thickness: 0.5, 0.8mm optional) 5.Lifespan: over100,000 times 6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V 7.Contact resistance: less than 50m 8.Insulation resistance: less than100M Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls; Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls. 10.Casing protective class: IP00 11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device. 12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole Structure and application: KI-32 serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state. Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat. Characteristics: Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio Precautions: 1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor. 2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation. 3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited. 4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection. 5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40.
Thermostat Detailed screw type bimetal thermostat description 1:auto rest 2:cremis shell 3.6.3*0.8 terminal 4:CQC UL VDE TUV SGS Detailed brass screw bimetal thermostat description fixation of the working temperaturing reliable snap action perdurable less radio interference Technical parameters: Electrical parameters: 1)CQC,VDE,UL,CUL AC250V 50~60Hz 5A/10A/15A (Resistance load) 2)UL AC125V 50Hz 15A (Resistance load) 2.Action temperature range: 45~160 (Optional); temperature accuracy: 3.Recovery and action temperature difference: 8~100 (Optional) 4.Connection method: Insert the terminal 250 bending angle: 0~90deg optional); Insert the terminal 187(bending angle: 0~90deg optional; thickness: 0.5, 0.8mm optional) 5.Lifespan: over100,000 times 6.Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V 7.Contact resistance: less than 50m 8.Insulation resistance: less than100M Junction method: Constant-closed: the contact point disconnects when temperature rises; and contact point connects when temperature falls Constant-opened: the contact point connects when temperature rises; and contact point disconnects when temperature falls. 10.Casing protective class: IP00 11.Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device. 12.Installation method: installed for KI031 series: general moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole Structure and application: KI-32 serial products are the temperature controllers taking bimetallic strip as the temperature-sensing unit. In case of normal operation the electrical appliance, the bimetallic strip is in a free state; the contact point is in a state of close/open. When the temperature reaches the action temperature, the bimetallic strip performs quick action generates caused by internal stress due to heating; open/close the contact point; disconnect/connect the circuit; thus, the temperature is in control. When the electrical appliance is cooled to the recovery temperature, the contact point automatically opens/closes to recover normal operation state. Widely used in electrical heating appliances like water dispenser, water heater, sandwich bread baker, dishwasher, dryer, sterilizing cupboard, micro-wave oven, electric heating coffee pot, electric cooker, refrigeratory, air-conditioner, laminator, heater of auto seat. Characteristics: Stable performance, high accuracy, small size, lightweight, high reliability, long lifespan, less interference to radio Precautions: 1.When adopting contact temperature sensing installation, the surface of the metal cover is required to be securely contacted with the installing surface of the controlled device. For ensuring the temperature sensing effect, it is required to coat thermal conductive grease or other similar thermal conductive medium on the surface of temperature sensor. 2.For reliable performance, collapse, loose or distorted top part of the cover is prohibited during installation. 3.Liquid inleakage into the controller, crackle in the casing and unauthorized change of external terminal position are prohibited. 4.When the product is used in the circuit with maximum current of 5A, the cable with copper core at section 0. 5-1mm2 is required for connection; When the product is used in the circuit with maximum current of 10A, the cable with copper core at section 0.75-1.5 mm2 is required for connection; 5.The product should be kept in a clean, dry and corrosive gas-free warehouse with good ventilation and at relative humidity below 90%, environment temperature below 40. Passed certifications :CQC UL VDE TUV SGS. according to customers' requirements.
Basic Info. Model NO.: KI31 Control Type: Digital Display Type: Blender Material: Plastic/ Ceramic Certification: CE/CQC/CB/UL/cUL/TUV Usage: Temperauter Control Type: Temperature Switch Max Voltage: 250V Max Current: 16A Body Material: Bakelite or Ceramic Temperature Characteristics: Normal Opened or Normal Colsed Terminal Angle: Horizontal or Vertical Terminal Type: 6.3mm or 4.8mm Export Markets: Global Additional Info. Trademark: HX Packing: Carton or According to Customers Requirements Standard: customized Origin: Dong Guan,Guang Dong ,China HS Code: 9032100000 Production Capacity: 3000000 PCS Per Month Product Description Technical parameters: Electrical parameters: 1)CQC, VDE, UL, cUL AC250V 50~60Hz 5A/10A/15A (Resistance load) 2)UL AC125V 50Hz 15A (Resistance load) 2. Action temperature range: -10~260Centigrade (Optional); Temperature accuracy: 10Centigrade 3. Recovery and action temperature difference: 8~100Centigrade (Optional) 4. Connection method: Insert the terminal 250# (bending angle: 0~90¡ã Optional); Insert the terminal 18(bending angle: 0~90¡ã Optional; Thickness: 0.5, 0.8mm optional) 5. Lifespan: ¡Ý 100, 000 times 6. Electrical strength: No spark or breakdown for 1min at AC 50Hz 1800V 7. Contact resistance: 50M 8. Insulation resistance: 100M Junction method: Constant-closed: The contact point disconnects when temperature rises; And contact point connects when temperature falls; Constant-opened: The contact point connects when temperature rises; And contact point disconnects when temperature falls. 10. Casing protective class: IP00 11. Grounding method: Connection is made between the metal casing of the temperature controller and the metal part of the grounding device. 12. Installation method: Installed for KI031 series: General moving ring, mini round moving ring, flat moving ring general aluminum cover with mounting hole, extra length aluminum cover with mounting hole Office Equipment Snap-action Thermostat Applications of KSD301 Thermostat 1. Water dispenser, Electric heater, Sandwich toasters, Dishwashers, Dryers, Disinfection cabinet, Microwave ovens, Electric coffee pot, Electric caldron, Refrigerator, Air conditioning gluing machine 2. Office equipment 3. The seat heaters. 1. 250V15A thermostat 2.Plastic body or ceramics body 3.Normal close or normal open 4. VDE TUV UL CE Certificate