Respirable Dust Sampler
The practise of assessing contaminants in the amount of air that can be inhaled by employees at a certain location is known as espirable dust sampling. To ensure that workers' health is not in danger, a variety of dust sampling techniques are employed to measure the amount of dust particles and chemical vapours.
With industrial employees who are frequently exposed to vapours, gases, and particles, respirable air sampling is fairly common. By monitoring the air, hazardous substances that are still present in the atmosphere can be found and effectively controlled.
Product Description
FDS (2.5 / 10) made by KDM PM TRAVELING FINE DUST SAMPLER (Can Monitor Either PM 2.5 OR PM 10 at a time)
Model-based on a microprocessor (DATA LOGGER FOR ALL 5 PARAMETERS)
Developed in accordance with international standards, USEPA regulations, and Indian CPCB guidelines
PM EPA 2.5 Size Separator PM 2.5 SUCCESS EPA Impactor PM 10 Size Separator Using a 10 separation assembly and a sample transfer tube, the omnidirectional ambient particle inlet.
Filter Cassette with a 47 mm Filter Media is placed in a Filter Holder assembly.
Volume Totalizer & Flow Rate Meter (USEPA Procedure Followed)
Actual operating conditions are shown as Flow in LPM on a Digital Display with a Resolution of 0.01 LPM.
Throughout the sampling period, the flow rate was kept constant at 16.67 LPM with a 2% accuracy thanks to a microprocessor-based digital flow controller.
Timer/Clock System
Programmable Real-time control system with automatic start and stop, digital time and date display, and sampling time display. Precision 2 min/month.
Temperature Sensors For Filter Temperature Range & Ambient Temperature
Range: 5 to 50 C with a 0.10 C resolution.
Range of the bar press sensor is 600 to 800 mm Hg. 1 mm Hg as the resolution
Display
20x4 LCD display calibrated by FCRI PALLAKKED presenting parameters in real time, i.e.
Flow Rate (16.67 LPM).
Volumetric flow, barometric pressure, ambient temperature, and filter temperature output are all included.
USB Flash Drive with RS-232C terminal for connecting to a computer (Optional)
Dimensions and Weight of Calibration Factory Calibration Certificate: (17x13x19)/Approx. 25 Kg
1.Real constant flow(fs10h) 3.Strong resistance to back pressure(up to 15kpa) 4.Easy to use 5.Small(125*70*48mm), light(490g)
Supplier: Safety spectacles for normal and industrial use, chemical goggles, dust mask, respirators FFP1, FFP2, FFP3, ear plugs and ear muffs, safety helmets, safety shoes, safety gloves, working industrial gloves, welding helmet, welding equipment, eyewash stations, first aid kits, work wear, coveralls, aprons, safety vests, warning tapes, scaffolding tags, flashlights, face shields, fire blankets and rolls, hand pallet trucks
Pigment Red Section 1. Identification Of The Substance/preparation And Company SUPPLIER: EMERGENCY TELEPHONE NUMBER: SUBSTANCE: Pigment Red TRADE NAME: 3120 Fast Brilliant Red SECTION 2. COMPOSITION/INFORMATION ON INGREDIENTS CHEMICAL NAME: 2-Naphthalenecurboxylic Acid, 4-[(5-Chloro-4-Methyl-2-Sulfophenyl)Azo]-3-Hydroxy-, Calcium Salt (1:1) CHEMICAL FAMILY: MonoazoCAS NUMBER: 7023-61-2 EC NUMBER (EINECS): 230-303-5 PERCENTAGE: 100% SECTION 3. HAZARDS IDENTIFICATION NFPA RATINGS (SCALE 0-4): HEALTH=1 FIRE=1 REACTIVITY=0EC CLASSIFICATION (CALCULATED): No classification assigned.MAJOR HEALTH HAZARDS: No significant target effects reported. PHYSICAL HAZARDS: Dust/air mixtures may ignite or explode. POTENTIAL HEALTH EFFECTS: INHALATION: Short Term Exposure: Irritation. Long Term Exposure: No information is available. SKIN CONTACT: Short Term Exposure: No information on significant adverse effects. Long Term Exposure: No information is available.EYE CONTACT: Short Term Exposure: No information on significant adverse effects. Long Term Exposure: No information is available.INGESTION: Short Term Exposure: Nausea, vomiting, diarrhea, stomach pain. Long Term Exposure: No information is available. CARCINOGEN STATUS: OSHA: N NTP: N IARC: N SECTION 4. FIRST AID MEASURES INHALATION: Remove from exposure immediately. Use a bag valve mask or similar device to perform artificial respiration (rescue breathing) if needed. Get medical attention. SKIN CONTACT: Remove contaminated clothing, jewelry, and shoes immediately. Wash with soap or mild detergent and large amounts of water until no evidence of chemical remains (at least 15-20 minutes). Get medical attention, if needed. EYE CONTACT: Wash eyes immediately with large amounts of water or normal saline, occasionally lifting upper and lower lids, until no evidence of chemical remains. Get medical attention immediately. INGESTION: If vomiting occurs, keep head lower than hips to help prevent aspiration. Get medical attention, if needed.
NT CAT T CAS:2212-32-0 Analysis and Precautions Introduction. CAS No.:2212-32-0 Molecular Formula: (CH3)2NCH2CH2N(CH3)CH2CH2OH Molecular weight: 146.23 Chinese name: 2-{[2-(dimethylamino)ethyl]methylamino}ethanol English name: 2-{[2-(Dimethylamino)ethyl]methylamino}ethanol English alias: 2-{[2-(Dimethylamino)ethyl]methylamino}ethanol Precise molecular weight/precise mass: 146.23 Applications. 2-{[2-(dimethylamino)ethyl]methylamino}ethanol (dmemH) has been used for the preparation of new iron clusters: [Fe7O4 (O2CPh) 11 (dmem) 2] [Fe7O4 (O2CMe) 11 (dmem) 2] [Fe6O2 (OH) 4 (O2CBut) 8 (dmem) 2] Conditions to be avoided. Heat, flame and sparks. Incompatible substances. Strong oxidizing agent, strong acid Waste disposal methods: This explosive product can be burned in a chemical incinerator with post-combustion treatment and scrubbing action Dispose of the remaining and non-recyclable solution to a licensed company. Contact a licensed professional waste disposal facility to dispose of the substance. Contaminated containers and packaging Dispose of as unused product. Safety Information. Hazardous Transport Code: Not available Hazardous Material Marking: Irritant Safety Marking: S26 Hazardous Marking: R36/37/38 Description of necessary first aid measures. Consult a physician for general advice. Show this safety technical note to the physician who arrives at the scene. Inhalation If inhaled, move patient to fresh air. If breathing stops, perform artificial respiration. Consult a physician. Skin contact Flush with soap and plenty of water. Consult a physician. Eye contact Flush thoroughly with plenty of water for at least 15 minutes and consult a physician. Ingestion Do not induce vomiting. Do not give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician. Storage and transportation. Should be kept sealed and stored in a dry, cool and ventilated warehouse Packaging. 200KG/drum Storage: It is recommended to store in a dry and cool area with proper ventilation. Please fasten the lid of the package as soon as possible after the original packaging to prevent the mixing of other substances such as moisture from affecting the performance of the product. Do not inhale dust and avoid skin and mucous membrane contact. Smoking, eating and drinking are prohibited in the workplace. After work, shower and change clothes. Store contaminated clothes separately and wash them before use. Maintain good hygiene habits.
Supplier: Gas Purification, Regulators, Gas Control & Selector Box, Auto Gas Changeover System, Hydrogen, Nitrogen, Zero Air Generator, Desiccant Air Dryer, Micro Filtration, Dry Nitrogen Evaporator, Precision, Laboratory Steel Furniture, Electrical Panels, Hplc, Gc Capillary, Chromatography Accessories, Regulator, Connector, Manifolds, Pressure Gauge, Air Compressor, Gas Cylinder Trolley, Gas Sampling Bomb, Gas Sampling Bladder, Flow Meter, Teflon, Pu Tube & Fittings, Pigtail, Stainless Steel Tubes, Fittings, Valves, Regulators, Gas Filters, Gas Flow Control System, Canister, Pressure Transducer, Igs, Cnc Plasma Cutting Machine, Cnc Plasma With Oxy Fuel Cutting Machine, Cnc Fiber Laser Cutting Machine, Cnc Router Machine, Pollution Measurement Instruments, Air Sampler, Dust Sampler, Puf Sampler, Pm10 Sampler, Gas Sampler, Ozone Monitor, Stack Monitoring System, Velocity Meter, Nox Sampling Equipment, Emission Sampling, Calibrator, Relative Humidity Meter, Temperature Indicator,
Combo Global Sampler We have produced and supplied the highest quality Combination Sampler for the Cement Industry from the day of our founding. For applications involving measurement and monitoring of air pollution, the combination sampler is employed in the cement industry. The customers can have a combination sampler in a variety of technical parameters depending on their demands for air pollution monitoring. Overview of the Global Combined Sampler Global is a special based firm that specialises in outdoor air monitoring equipment, air pollution management tools, and air monitoring & measuring equipment while providing high-quality products and services. Every piece of pollution monitoring equipment produced by Global Delhi is put through testing to ensure the highest level of quality control.The brand name Global is known throughout India and stands for best quality, best value, and best assistance. For the Environmental Services, Measuring Air Pollutants, Air Quality and Pollution Instruments, and Pollution Measuring Instruments of Global. Global's goal is to advance the delivery of Pollution & Dust Particle Monitoring Equipment, Air Sampler, Dust Sampler, and Combination Air Sampler through the excellence, scope, and global appeal of key instructional and recreational products. Global is engaged in the production and delivery of extremely effective Combined Dust Samplers/Combo Samplers thanks to our beneficial experience. Due to its great efficiency and widespread Global Combined Samplers (Combo) are frequently utilised to measure airborne particle concentrations. PM 10 is the combined sampler specification. PM 2.5 Separator: PM 2.5 Separation through a WINS Impactor Separator: Omni Directional Air inlet with PM 10 Separation through Impactor Flow Rate: The crucial orifice system maintains a constant sampling rate of 1 m3/hr that is unaffected by voltage fluctuations and filter choking. Filter Media: The filter holder is made to accommodate any 47 mm dia. standard filter media. Oil-free, non-pulsating suction pump with an induction motor for constant flow rate Sample Volume: A dry gas metre logs the entire volume of air that was sampled. 220V 10 V AC, 50Hz 3% single phase is the required amount of power. Simultaneous sampling of PM10 and PM2.5 Particulates is one of the combined sampler's features. PM2.5 filter is always kept at a temperature that is similar to ambient thanks to the two-part cabinet. Even in places with high PM concentrations, a low sampling rate of 1 m3/hr reduces filter clogging. Crucial Orifice keeps flow rate steady
Description This handy air sampler is portable and operates on both a mains power source and a rechargeable battery. For the purpose of monitoring air quality, this is helpful for gathering air samples. This is the best monitoring tool for indoor air quality. It includes a pump, a digital timer, a rotameter (05 LPM), and a flow controller with space for storage sampling equipment in a small stainless steel box. uses a rechargeable lead acid battery from SMP. When ingested, chemical compounds that are disseminated in the office environment as gases, vapours, and aerosols may have a variety of harmful health impacts. To assess the quantities of contaminants, the Handy Sampler is employed. Uses include the identification of air contaminants such dust, acid mist, ammonia, H2S, and free chlorine. the evaluation of individual exposures. the general background levels to be discovered. to assess the success of the control. to determine STEL and TWA values. Analytical Sampling Devices: The type of contaminant will determine which analytical procedures are used. FILTER PAPER HOLDER FOR DUST MONITORING - The gravimetric method may be used to measure dust. if it contains metals or compounds made of them. The Atomic AbsorbtionSpectophotometer can be used to analyse it. IMPINGERS FOR GAS & VAPOURS ANALYSIS OF ORGANIC GAS SUCH SO2, NOX, ETC. It uses the titrmetric or spectrophotometric method.
PERSONAL AIR SAMPLER INTRODUCTION THERE IS A CHANCE THAT WORKERS AT MANY INDUSTRIAL AND CONSTRUCTION SITES WILL BE EXPOSED TO HAZARDOUS DUST, VAPOURS, AND GASES. SINCE INHALATION IS TYPICALLY THE MOST MAJOR ROUTE OF ENTRY INTO THE BODY, IT IS CRUCIAL TO PAY CLOSE ATTENTION TO THE AIR THEY ARE BREATHING. IN GENERAL, WE USE A SAMPLE PUMP TO EXTRACT A KNOWN VOLUME OF AIR THROUGH AN APPROPRIATE SAMPLING MEDIA. FILTER PAPER OR OTHER SUITABLE SOLID MEDIUM WOULD BE USED FOR PARTICLES AND FUMES, AND A SORBENT TUBE, OR PERHAPS AN IMPINGER OR BUBBLER, WOULD BE USED FOR GASES AND VAPOURS. WITH THE SAMPLER SITUATED IN THE BREATHING ZONE, A TYPICAL SAMPLING TRAIN FOR PERSONAL MONITORING WOULD RESEMBLE THIS; Gas sampling bags, like Tedlar bags, are used for collecting samples of gases. Moreover, background exposure can be measured using passive or diffuse sampling methods. They are sealed badges that are sampled, worn on the individual for the specified amount of time, sealed, and then sent off for analysis. To enable hands-free sampling of inhalable gaseous pollutants and particulate matter in the air actually breathed by the person at work, Personal Air Sample is a battery-operated tiny air sampler that may be fastened on to a person. Uses include: monitoring fugitive gas emissions in the workplace, workplace air quality, and workplace monitoring. They are also used in places of employment for businesses in the chemical, paint, cement, sugar, and other industries. Features of the physical design include a holder for the sampling medium, a suction pump, a flow measurement device, a flow controller, and a battery for each personal air sampler. For sampling of dust or particles, a suitable filter that has been placed in a filter holder serves as the sampling medium. An adsorption tube that is filled with pollutant-specific adsorbents like activated charcoal, tenax GC, etc. serves as the medium for sampling gases and vapours. The filter or the adsorption tube must be the only one of the two media being utilised at once. The suction needed to draw air through the sampling media is provided by a low power diaphragm type suction pump. A large capacity rechargeable Li-ion battery powers it. A tiny rotameter that has been carefully built can measure flow.A ball valve, a needle valve, or an electronic circuit can be used to control flow. A battery-operated model with a rechargeable battery is one of its key features. Used to monitor the air quality in workplaces or on shop floors. Small and Lightweight, weighing under 500 grammes To assess TLV exposure, the filter holder or adsorbing tube can be held at the level of inhaling. May be worn by the user Model that is lightweight, convenient, and reasonably priced.