Porcelain High Voltage Fuses for Transformer Protection, high quality with copper material. 12KV 24KV 35KV Fuses.
Technical parameters for XRNT-36KV fuse: Rated voltage: 36KV Rated current of fuse: 25A Dimension: 442mm*51mm Type Rated voltage (KV) Rated current (A) Diameter (mm) Length (mm) XRNT1 3.6 6.3 10 16 20 25 31.5 40 51 192 XRNT1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292 XRNT1 7.2 80 100 125 160 76 292 XRNT1 12 10 16 20 25 31.5 40 51 292 XRNT1 12 50 63 71 80 100 76 292 XRNT1 12 125 76 292 XRNT1 12 160 200 88 292 XRNT1 24 6.3 10 16 20 25 31.5 40 51 442 XRNT1 24 50 63 71 80 100 76 442 XRNT1 24 125 76 442 XRNT1 24 160 88 442 XRNT1 40.5 3.15 6.3 10 16 20 25 51 537 XRNT1 40.5 31.5 40 76 537 XRNT1 40.5 63 88 537 3pcs a carton
Type k high voltage fuse link for dropout fuse cutout. 1). Product description: This fuse wires apply to the 11kv -36kv drop out fuse. 2). Standard: According to ansi/ieee c37.41-2000 and iec-282 standard. 3). Technical specification: Rated current: 1a-300a Rated voltage: 11kv-27kv Length: 530mm-600mm (23 inch) Length of fuse link can be make according to requests. 500pcs a carton
1. Use (H) RW 12-27 drop fuse and pull-load drop fuse are outdoor high-voltage protective appliances, which are assembled on the high-voltage side of distribution transformer or branch lines of distribution line, and are used for overload and short-circuit protection of transmission lines and power transformers and for sharing rated load current. 2. Brief introduction of structure The drop fuse consists of two parts: insulating bracket and fuse pipe. The static contacts are installed at both ends of the insulating bracket, and the movable contacts are installed at both ends of the fuse pipe. The fuse pipe consists of an inner arc extinguishing tube and an outer epoxy glass tube. Pull-load drop fuse adds elastic auxiliary head and arc extinguishing cover to divide and close load current. When a drop fuse is in normal operation, the fuse pipe is tensioned by means of the fuse. Then a closed position is formed. When the system fails, the fault current causes the fuse to fuse rapidly and form an arc. The arc extinguishing tube is heated by the arc and decomposes a large number of gases, which forms a high pressure in the tube and blows longitudinally along the pipeline. The arc is rapidly elongated and extinguished. After the fuse is fused, the lower moving contact loses tension and turns down. The locking mechanism releases the fuse tube, and the fuse tube falls down, forming an obvious breaking position. When the load needs to be pulled, the contact is pulled by the insulating rod. At this time, the active and static contacts are still in contact. The contacts are pulled by the insulating rod, and the auxiliary contacts are separated. Arc is generated between the auxiliary contacts. The arc is elongated in the slot of the arc extinguishing hood. At the same time, the arc is extinguished when the current passes zero. 3. Implementation criteria The product performance conforms to GB15166.3-94 national standard and IEC282-2 international standard. 4. Conditions of Use 1. Environmental temperature: - 40 ~40 C; 2. No more than 1200 m above sea level; 3. The wind speed is not more than 35m/s. 4. Earthquake intensity does not exceed 8 degrees. 5. Fuses are not suitable for the following places: A. Places where there is a danger of combustion or explosion; B. Places with violent vibration or shock; C. Areas with heteroelectrochemical gases, severe air pollution and salt fog. 5. Instructions for Order 1. Product type, name, rated voltage, rated current and rated switching-on current; 2. Environmental requirements (anti-pollution, plateau type); 3. Special requirements can be consulted with our company. Manufacturer of intelligent switch cabinet--low-voltage, high voltage power distribution switch cabinet, also have many other electric equipment electric power accessories, intelligent transmission and distribution automation system
Din hrc "s" type high voltage fuse for transformer protection: 1. According to bussmann din "s" type high performance back-up fuse 2. Comply with iec282-1, din, bs 3. This fuse is intended to protect distribution networks and transformer, for indoor as well as outdoor use. 4. Any other specifications can be designed specially. Type rated voltage (kv) rated current (a) diameter (mm) length (mm) Xrnt1 3.6 6.3 10 16 20 25 31.5 40 51 192 Xrnt1 7.2 6.3 10 16 20 25 31.5 40 50 63 51 292 Xrnt1 7.2 80 100 125 160 76 292 Xrnt1 12 10 16 20 25 31.5 40 51 292 Xrnt1 12 50 63 71 80 100 76 292 Xrnt1 12 125 76 292 Xrnt1 12 160 200 88 292 Xrnt1 24 6.3 10 16 20 25 31.5 40 51 442 Xrnt1 24 50 63 71 80 100 76 442 Xrnt1 24 125 76 442 Xrnt1 24 160 88 442 Xrnt1 40.5 3.15 6.3 10 16 20 25 51 537 Xrnt1 40.5 31.5 40 76 537 Xrnt1 40.5 63 88 537 3pcs a carton
Advantages: 1. Full scope protection 2. High breaking capability 3. High voltage current limiting fuse 4. Design as customer required 5. Utility model patent 6. Appearance design patent Specification: Material: ceramic Color: white, brown Length: 142mm, 192mm, 195mm, 260mm, 355mm, 465mm Diameter: 22mm, 25mm, 51mm Type rated voltage (kv) rated current (a) diameter (mm) length (mm) Xrnp1 3.6 0.5 1 2 3.15 6.3 22 25 142 Xrnp1 7.2 0.5 1 2 3.15 6.3 22 25 142 Xrnp1 7.2 0.5 1 2 3.15 6.3 22 25 192 195 Xrnp1 10(12) 0.5 1 2 3.15 22 25 192 195 Xrnp1 24 0.5 1 2 3.15 22 25 355 Xrnp1 24 0.5 1 2 3.15 30 365 Xrnp1 40.5 0.5 1 2 3.15 30 465 3 pcs a carton
Supplier: All kinds type of fuse, igbt module, scr thyristor, bridge rectifier, low /high voltage fuses, super rapid fuse, hrc fuses
Supplier: High voltage dc relay/contactor, high voltage dc fuse
Supplier: Stainless steel cable tie, high voltage fuses, surge arresters, separable cable connector, clamps
Supplier: Low voltage & high voltage fuses, DC fuses, DC spd, DC breaker, solar connector, solar cable, circuit breaker