Catheter / Line Securement Device StatLock PICC Plus
UOM: 50/CS
Product Number: VPPCSP
Manufacturer: BD
Catheter / Line Securement Device Statlock PICC Plus UOM:50/BX Product Number: PIC0220 Manufacturer: BD
EZ Well KF94 Quarantine Mask is a quality product approved by the Korean Ministry of Food and Drug Safety. In addition to this, has both FDA and CE certified Respiratory protection from harmful particulate matter such as yellow dust, fine dust, and infectious sources 1. The three-dimensional quadruple structure certified by the Korean Ministry of Food and Drug Safety securely blocks the outside (4 Layer using a melt-blown filter) 2. A fine dust mask that is comfortable to breathe because it does not touch your mouth! Excellent breathability. 3. It adheres smoothly along the face line and prevents fogging with the nose wireframe and ear wireframe. 4. It has an Excellent Mark from DermaTest in German which did not lead to toxic-irritative intolerance reactions in patch testing carried out in accordance with international guidelines
Features 1. Size: for adult 2. Available for 3 layers or 4 layers 3. OEM/ODM/Customization are available The design creates more space between the mask and the mouth, leading some wearers to say they're more comfortable than typical respirators. There are three kinds of masks with different functions- Standard, Smile and Sport. Standard: Ergonomic design first seamlessly around your face line, securing sufficient space for easier breathing and a more comfortable wear.
can provide some general information based on the components mentioned. HAKKO SONOGUIDE: HAKKO is a company that produces a range of medical products, including medical devices and equipment. PTC Needle (PTCB:18G*200mm): "PTC" likely refers to a percutaneous transluminal catheter or a similar medical device used for procedures like angioplasty. "18G*200mm" indicates the gauge and length of the needle. In this case, it suggests an 18-gauge needle with a length of 200mm.
Cordis is a well-known medical device company that produces a variety of products, including devices used in interventional cardiology and vascular procedures. The Cordis Saber PTA balloon is likely designed for use in percutaneous transluminal angioplasty procedures. Angioplasty is a medical procedure used to open narrowed or blocked blood vessels, typically arteries, to improve blood flow. During angioplasty, a balloon catheter is inflated at the site of the blockage to widen the vessel and restore blood flow. Here are some general features you might expect from a PTA balloon like Cordis Saber: Balloon Material: The balloon is typically made of materials like polyethylene or polyurethane. Inflation System: It would likely have an inflation system that allows controlled inflation and deflation of the balloon during the procedure. Catheter Design: The balloon is mounted on a catheter, which is a flexible tube that allows the device to be threaded through blood vessels to the site of the blockage. Guidewire Compatibility: PTA balloons are often designed to be used with guide wires for precise placement.
The EV3 SpiderFX is commonly associated with the SpiderFX Embolic Protection Device, which is used in the field of interventional cardiology. The device is designed to capture and remove embolic debris that may be released during certain vascular procedures, particularly during carotid artery stenting. Key features of the EV3 SpiderFX Embolic Protection Device may include: Embolic Protection: The primary function of the device is to provide protection against embolic debris dislodged during the intervention. It helps prevent these debris from reaching and potentially blocking smaller blood vessels. Flexible Design: The SpiderFX typically has a flexible design that allows it to navigate through blood vessels, facilitating the deployment and retrieval process. Distal Protection: The device is designed to be positioned distal to the treatment site, capturing any embolic debris before it can travel downstream. Capture Basket: The device often includes a capture basket that traps and retains embolic debris, preventing it from causing harm in the circulation. Compatibility: The SpiderFX device is designed for compatibility with various catheters and guide wires commonly used in interventional procedures.
Guide wires are commonly used in medical procedures, particularly in cardiology and radiology, to guide catheters and other devices through blood vessels or other anatomical structures. The Terumo Radifocus Guide Wire M is likely designed for use in vascular interventions. Here are some general characteristics you might find in Terumo guide wires: Material: Guide wires are typically made of materials such as stainless steel or nitinol. Coating: Some guide wires may have hydrophilic or hydrophobic coatings to enhance their performance during navigation through blood vessels. Tip Design: The tip design may vary based on the intended application, with options like floppy or stiff tips. Diameter and Length: Guide wires come in various diameters and lengths to suit different procedures and anatomies. Radiopaque Markers: Radiopaque markers help visualize the position of the guide wire under fluoroscopy.
The Hem-o-lok Ligating Clip System, produced by Teleflex under the Weck brand, is a medical device used in surgical procedures for the ligation (closing off) of vessels or tissue structures. The Hem-o-lok clips are commonly utilized in laparoscopic and robotic surgeries. Key features and aspects of the Teleflex Weck Hem-o-lok Ligating Clip System include: Material: The clips are typically made from a polymer material, providing a secure and reliable closure when applied to vessels or tissues. Design: Hem-o-lok clips are designed to be easy to use, with a simple mechanism for application. They are available in various sizes to accommodate different surgical needs. Application: Surgeons use Hem-o-lok clips to occlude or ligate blood vessels or other structures during surgery. These clips are widely used in minimally invasive procedures, such as laparoscopic and robotic surgeries. Secure Closure: The design of the clips aims to provide a secure closure, preventing bleeding or leakage from the ligated structures. Color Coding: The clips are often color-coded according to size for easy identification during surgery, allowing surgeons to choose the appropriate clip for the vessel or tissue being ligated.