Overview
Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient.
I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test.
CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS.
Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test.
220V single power input and avoids the risk of using 380V.
Current transformer volt-ampere characteristic tester
Main Technical Parameters:
Booster output current & voltage
1A/2500V
2A/1500V
5A/600V
10A/220V
20A/30V
Current generator output current
600A
Output power
3000VA
Voltage and current measurement accuracy
0.2%
CT ratio tests
Range
1~40000
Voltage method / current method
Accuracy
0.2%
PT ratio tests
Range
1~40000
Accuracy
0.2%
Phase measurement
Accuracy
5min
Resolving power
0.5min
Secondary winding resistance tests
Range
Accuracy
0.52m
AC load tests
Range
0~1000VA
Accuracy
0.5% 0.05VA
Power supply
AC220V 10 50Hz
work environment
Size & Weight
Size: 425 mm 290 mm 310mm
Weight: 30kg
Overview Current transformer volt-ampere characteristic tester Only need to set the test voltage, current and step, the device will boost and trace voltage current characteristic test curve automatically, save the cumbersome labor of manual pressure regulation, artificial record, tracing curves, and so. Quick, simple and convenient. I can not only test CT/PT DC resistance, volt-ampere characteristics, ratio and polarity, 10% error curve, angle difference and ratio difference, but also test secondary load of transformer, CT current test and PT AC withstand voltage test. CT ratio not only supports traditional current method but also voltage method, so it can meet the test of CT in casing CT and GIS. Volt-ampere characteristic test single machine output voltage 0-2500V, current 0-20A, can meet most of the transformer volt-ampere characteristic test. 220V single power input and avoids the risk of using 380V. Current transformer volt-ampere characteristic tester Main Technical Parameters: Booster output current & voltage 1A/2500V 2A/1500V 5A/600V 10A/220V 20A/30V Current generator output current 600A Output power 3000VA Voltage and current measurement accuracy CT ratio tests Range 1 -40000 Voltage method / current method Accuracy PT ratio tests Range 1 - 40000 Accuracy
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. We can supply small transformer from 33kV and up to 54000kVA or more. For more details please contact us.
We can supply solar transformers ideally suited for large MW scale solar PV plants. Bullet Points - . Inverter duty Solar transformers, suitable for solar load profile . Multi-winding (2 to 6 windings), oil-filled or dry type. . 2MVA to 12.5MVA, LV Side: 0.35kV to 0.69kV, HV Side 3.3kV to 33kV . Low-loss, with Aluminum or Copper winding. . Electrostatic shield between LV and MV Winding. For more details please contact us.
For price, specification and other details please contact us
It is used as an addictive of sulphur in Iron and steel smelting to improve the cutting performance. Origin - India and China For price, specification and other details please contact us.
Supplier: Transformers and other electrical products, clothing, cosmetics, general merchandise