MAN series natural gas engine generator & CCHPs, from 50kW to 600kW, high performance & high efficiency for project of cogenerator of WtE (waste to energy) & distributed energy system.
EMN Natural Gas Cogeneration Series include100kW,200kW, 250kW, 300kW, 400kW, 500kW.
As a leading manufacture and assembler for whole gas engine generator set & CHPs in , ETTES mainly adopt MAN engines of E0834, E0836, E2676, E3262, and E3268 etc, with features of Proven and fully developed, Flexibility and individuality, Robust and compact, High Efficient and Low emissions. In addition to standard package of electrical generation, clients special requirements can be tailored such as CHP, CCHP, Cogeneration, ATS, Parallel operation system, Remote monitor & Control, Modularized soundproof & weatherproof container.
We have 4sets of used Detroit generators that were used as emergency power sources (Standby only) at a municipal water drainage plant in Korea. Please review the attached documents and assess ENGINE SPECIFICATION ENGINE MODEL Detroit Diesel 8163-7416 1232HP ENGINE NO. 16VF013546 RPM 1,800 Cylinder 16 Injection method Direct injection Cooling method Water Cooled Fuel consumption rate 246â??/h GENERATOR SPECIFICATION (AC Generator, 3�?, 60Hz, Brushless type Generator Model DIG 4800 Emergency output 990 kVA / 792 kW Continuous output 900kVA / 720kW Voltage and Current 600 v x 86.6 A Revolution 1800RPM Excitation Voltage/Current 65V/10A Power Factor 80% Insulation Class F
We have a stock of quality, low-life generators from the military ï?¬ CAT 3408 400kW ï?¬ CAT C-16 500kW ï?¬ CAT 3406 350kW (House type) ï?¬ Cummins VTA-28G5 500kW ï?¬ Cummins LTA-10 250kW (House Type) ï?¬ Cummins LTA-10 250kW ï?¬ Cummins NT85-G3 350kW ï?¬ Cummins NT85-G3 350kW (House type) ï?¬ Cummins NT85-G2 300kW Please study if it is suitable for your market.
Supplier: Biogas engine generator sets, natural gas engine generator sets, hydrogen engine generator sets, syngas engine generator sets, diesel engine generator sets, engines, generators, maintenance spare parts
Services: Maintenance
POWER OUTPUT400KW, 60HZ, RPM1800, ENGINE TYPE V12, DSL238, ENGINE POWER425.
We Are A Prominent Organization Engaged In Offering A Wide Range Of Generator Parts, Electrical Goods, Lubricants Oil, Industrial Ancillaries, Construction Equipment Parts. These Products Are Highly Durable And Cater To The Requirements Of Diverse Industries.
Tide Power System China TPS Series Gas generator set was powered by Cummins, Deutz, and TPS gas engine, these engines are equipped with Advanced Gas Egnine ECU, USA Altronic/Bosch/NGK Ignition System, Woodward speed governor system, Woodward/Heinzmann/Impco Air-Gas Mixing System to achieve lean-burn technology which is same as CPG CUMMINS gas generator set. Gas Genset Output: 25kw-500kw Gas Engine Series: CG / DG / TPG series. Alternator: TPS, Leroy Somer, Marathon, Siemens Control Panel: Comap, Deepsea, Harsen Gas Train: ball valve, gas filter, gas pressure regulator, pressure gauge, electromagnetic valve; (Germany DUNGS brand optional ) HZ&RPM: 50HZ&60HZ, 1500/1000RPM& 1800/1200RPM Acceptable Gas: Natural gas, LPG, CNG, Biogas, colliery gas, landfill gas, sewage gas etc.
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 200 Engine Model : 1106A-70TAG3 Stand By kVA: 200 Stand By kW : 160 Prime kVA: 182 Prime kW : 145 Rated Current : 262 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Model 1106A-70TAG3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 180.2 / 243,5 Prime Power Hp 162.7 / 220 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 41,5 Lt %75 LOAD 31,8 Lt %50 LOAD 20,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.