Fractional non-ablative 1550 nm laser system. With patented SoftCool air cooling for patient comfort. Ydun delivers fractional nonablative 1550 nm laser.
Price/unit : usd 16, 921 Please contact us for more specifications this product. This is a 2005 ellipse that has under 20, 000 total pulses of use on both handpieces. It is in perfect working order and comes with all accessories. Ellipse i2pl highlights the ellipse i2pl represents the next generation in intense pulsed light technology. The i2pl features candela’s exclusive dual mode filtering, eliminating exposure to harmful wavelengths and reducing treatment times while maximizing patient results and comfort. There has never been a more sophisticated ipl for skin rejuvenation. Square pulse technology – ensures that light reaches the desired intensity immediately and remains consistent throughout the treatment, for safer and more effective results. Versatile and convenient – comprehensive skin rejuevenation offering two handpieces which allow you to change between treatment options merely by touching the screen. And the ellipse i2pl is lightweight and easy to move from one treatment room to another. Easy to use – the built-in computer calculates safe treatment parameters for each patient and on-screen prompts guide you every step of the way. Procosmeticlaser.Com In box (fedex, ups, ems, dhl)
The Precitec laser cutting copper nozzle can assist the gas to eject rapidly, which can effectively prevent the debris from falling upward and thus protect the focusing mirror. At the same time, it controls the diffusion area and size of the gas, thus affecting the cutting quality of the laser cutting machine. Single nozzle is used for melting cutting, that is, nitrogen is used as auxiliary gas to cut stainless steel and aluminum plate. Double nozzles are commonly used for cutting oxygen, which uses oxygen as an auxiliary gas for cutting carbon steel. Advantage: Advantage: 1. Made of high quality copper material, can provide stable signal transmission. 2. High processing precision, high light inside the stack surface, airflow barrier through, less slag, no burrs, cutting easily. 3. The strict oxidation prevention process, copper bright, smooth surface, can effectively prolong the use of time. 4. Suitable for market mainstream brands, such as PRECITEC, Han, laser, Wan Shunxing, Jin Yun, Dican, Hong Shan, Jia Qiang, Chutian, thunder, high energy and other fiber laser cutting head. At the same time, the choice of the nozzle aperture size will vary according to the thickness of the cutting material. 1.Cutting thin plate (3mm below): choose diameter 1mm aperture nozzle, cutting effect will be relatively fine, and choose diameter 1.5mm aperture of nozzle will be thicker, and the corner of the place will be easier to stain. 2.Cutting plate (above 3mm): choose to use 1mm when the diameter of the nozzle aperture is not stable, because the cutting power is higher, the relative cooling time is longer, the relative cutting time increases, with 1mm aperture diameter nozzle gas diffusion area is small, so it is not too stable, but basically can still be used. The nozzle with a diameter of 1.5mm diameter has a large gas diffusion area and a slower gas flow rate, so it is stable when cutting. 3.Cutting more than 10mm of the plate. At present, 2mm or 2mm diameter nozzle is usually chosen. Note: Some 0.8/1.0/1.2/1.4/1.5/1.8/2.0/2.5/3.0/4.0 aperture size, please select need output aperture.
Material Fused Silica Lens Diameter 13.8mm ±0.1mm Edge Thickness 1.5mm ±0.1mm Laser type 1064nm (BBAR 1020nm-1080nm) Optical Coating Both sides AR/AR@1064nm(1020nm-1080nm) Application YAG/Fiber laser cutting/welding/Cladding machines Laser power 500w-6000w
Specifications A8 super pulse 30W CO2 laser treatment apparatus is called "photon scalpel of cosmetology" The unit has the finer and the shar The Ultra pulse Fractional Laser System The A8Generation-2 Ultra Pulse Co2 Fractional Laser System, with 4 working modes as pulse, Scanning, Ultra Pulse and Continuous, could do various of high-demanded laser treatment safely and effectively, specially for aesthetic surgery and dermatology. It virtues for its 4 advantages, that is, high precision operation ,tiny thermal injury , short treatment time, quicker recovery time. With highest-integrated and ultra-high-speed Graphics Scanner, the machine could scan various of non-linear fashion with different size and shape. The scanning shape could be specially designed for customer¡¯s different needs, either 2 modes could be chosen in the 11 scanning modes. It also virtues as its Dynamic Balance and Compensation Install for Remedying Energy Attenuation. The machine could automatically compensate more energy when the energy of the laser tube reduces, without needing operators reset the treatment parameters according their own experiences. System Feature ¡¤Green guiding light make operation vision clearer¡¤For skin resurfacing and for dermatology cut/surgery.¡¤Various power supply for European, American and area needs.¡¤Smaller and lighter scanner(volume:7x4x11cm, weight:240g) for more convenient operation.¡¤With background set for operation time and machine use time.¡¤With time-accumulater for showing total operation time and machine use time.¡¤Friendly designed in modular for easy maintenance, with red and green light to guide it.¡¤Friendly designed for high safety, with warning-alarm-set. Clearly showed on the display screen.¡¤With energy self-replenishment system, improving the electric flue automatically to ensure real screen.¡¤With high cost-effective, great quality, best accessories, made by most skilled workers and engineers.¡¤With cooperation beauty hospital ,each machine should be first perfected in hospital, then customers.¡¤Committee of China Laser Standard Association, Executive of Laser Branch of china Optical Society. Application: It is applied in stripping ,cutting and vaporization. Specially, for skin rejuvenation, improvement of pachylosis, large pores, complexion unbalanced and so on. It has notable effect of removal scars, winkles, pigmentation, stain, acne, moles, nevus, hemangioma, skin tag and so on. Acne scars,Surgical scars,Traumatic scars,Actinic scarsMelasma (mask of pregnancy)Skin resurfacing (to improve texture)Wrinkles around the eyes and mouthPigmented lesions : age spots/brown spots/sun spots/Red vascular removal Fractional laser working principle With fractional CO2 laser resurfacing , the laser beam is broken up pr fractionated into many small micro beams which are separated ,so that when they strike the skin surface small areas of the skin between the beams, the skin would not be hit by the laser and left intact. These small areas of untreated skin promote a much more rapid recovery and healing time, with less risk of complications. While the small areas treated by the fractional micro beams, called micro treatment zones, cause sufficient laser injury to promote new collagen production and resultant in facial skin rejuvenation. As these treated areas are much smaller than the surrounding healthy tissue, the healing time is significantly shortened. Most fractional CO2laser patients heal in less than one week for facial treatment. It provides results almost as good as traditional full-surface CO2laser, but with far less risk, downtime, infection and complication. Nicely, it can also safely treat other areas besides face, producing excellent results in treating neck, hands and back, such as skin laxity, acne scars and wrinkles. But only one to two treatment are needed for up to an 85% improvement. Traditional full-surface CO2laser treatments are performed by using a beam of intense laser energy, which is passed over the skin surface to vaporize the entire top layer of skin. The damage to the tissue is extensive, it takes at least tow weeks to heal and regrow a new top layer of skin(i.e., re-epithelialize the entire top layer of skin). Technical Specification Wave Length: 10.6umOutput Power: 1-30W adjustableMicro Pulse Energy: 5mj-100mj,16 steps adjustableEstimated Power: 125mj-1kjScanner Focus: 50mm (FFLS) or f=100mm (HFLS)Focus Spot Diameter: 0.1mm (FFLS) , 0.2mm(HFLS)Treatment Depth: 2000um (FFLS),600um(HFLS)Conducting Beam: Green Semi-conductor laser (532nm,=mW)Control System: microcomputer controlSmoke Emission System : Built-in air blowCooling System: Water coolingDisplay Screen: color LCD (8 inch touch screen)Light Delivery System:7 Joint articulated armWorking Mode: with scanner (galvanometer scanning)FFLS scanning area: max 15x15mmHFLS scanning area: max 15x15mmScanning mode: Ellipse, Rectangular (standard)Scanning velocity: 10m/sCW: output power,1-30w, 1W adjustableUltra: Frequency, 1000HZ, 1HZ adjustableTreatment control: footswitchEnvironmental Temperature: 5-40CRelative Humidity:80%Machine Weight: 40kgMachine Dimension: 450mm x 550mm x 1400mmPower Supply: AC 220/110V;50/60HZ. wooden
Supplier: Fiber laser protective windows, laser lens, laser focus lens, laser ceramic ring and nozzles, cynosure candela laser focus lens and slider windows, ipl sapphire crystal uvfs ipl prism bk7 ipl light guide
Fractional CO2 laser vaginal rejuvenation machine Application Mode I: Co2 laser skin rejuvenation&scar removal machine Fractional System Co2 laser skin rejuvenation&scar removal machine Application Skin Resurfacing Scar removal , acne scars , burnt scars and surgery scars ,etc . Wrinkle removal ,Stretch mark ,age spots ,freckles ,wart etc removal Collagen stimulation Dermatological surgery Technical Specifications: Wavelength 10.64um Power Output 1-40W Laser Type UltraPulse; CW; Fractional Spot Size 0.12mm & 1.25mm (adjustable) Spot Density Up to 102400 dot Scan Size Up to 20x20mm Scan Shapes Square; Rectangle; Circle; Triangle; Rhombus; Ellipse; Line Beam Patterns Standard; Random; Scatter Aiming Beam 5mW red diode laser, 635nm, adjustable intensity, blink on/off Beam Delivery Articulated 7-joint arm with up to 360 rotation Cooling Self-contained, closed cycle Stand-by Working Continuously for 18 hours Display 10.4" True Color LCD Touch Screen Electrical Requirements 100-240VAC, 20A max., 50/60Hz Net Weight 52 kgs Dimensions (WxDxH) 52*38*117cm