Alstom Gbcdd21pf9353ach
Dir.idmt O/c Relay 1va 1.3 Secs (Non-std
Technical Specification
Cdd21
Relay Model Cdd21pf9353ach
Case Size 1-1/2d Vert. 10t
Application O/c
C.t. Secondary 1 Amp Ct.
Current Setting 0.5 - 2 Amps
Burden 1 Va
D.m.t 1.3 Sec
Taps Std
Aux.multi Voltage 100 - 125 /220 250 V Dc
Contacts (S/r or H/r) 2 N/o S/r
Flag Yes
Mounting Flush
Mta Phase-char Angle 30 Degrees
V.t/p.t Secondary 110 V Ac
Frequency 50 Hz
Name Plate-1 Rfg9126-017
Outline Drawing Mfj013
Wiring Diagram Mpdz801-10-1
GBCDG61EG044SHCH IDMT 3 O/C RELAY WITH HIGH SET CAG 13 Technical specification Relay model no - CDG61EG044SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 3 O/C Current setting - 0.5 to 2 amps Contacts / Output contacts - 2 N/O 2 N/C H/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs High set - O/C Setting - 4 to 16 amps High set - CAG 13 High set contacts - 2 N/O S/R Name plate - RFG9126 771 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG058SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG058SGCH Relay type CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 2.5 to 10 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden / Taps - 3 VA / Std Operating time - 1.3 Secs Current setting - E/F - 0.5 to 2 amps High set - O/C Setting - 25 to 100 amps High set - E/F Setting - 10 to 40 amps High set / High set cont. - CAG 13 / 2 N/O S/R Name plate - RFG9125 903 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31
Gbcdg61eg101znch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zn(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o 2 N/c H/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c or O/v Setting - 2.5 - 10 Amps. Name Plate Rfg9126 774 Outline Diagram Mfj 014 Wiring Diagram Madz821.32
GBCDG61EG101ZRCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical Specification Model No - CDG61EG101ZRCH Relay Type - CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amp C.T. O/C Setting - 2.5 - 10 Amps. E/F Setting - 0.5 - 2 Amps Contacts - 2 N/O S/R Flag - Yes Frequency - 50 Hz Burden / D.M.T - 3 Va / 3 Sec High Set Type / Conts. - CAG17 / 2 N/O S/R Highset O/C Setting - 12.5 - 100 Amps. HighSet E/F Setting - 5 - 40 Amps Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.31
GBCDG61EG101ZSCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI TECHNICAL SPECIFICATION Model No - CDG61EG101ZSCH CDG61/CAG17(MRK-III) Application - 2 O/C + 1 E/F Case Size - 3D Horz C.T. Secondary - 5 Amps O/C Setting - 2.5 - 10 Amps. Frequency / Tap - 50 HZ / Std Burden / D.M.T - 3 Va / 3 Sec Contacts - 2 N/O 2 N/C H/R E/F Setting - 0.5 - 2 Amps. Flag - Yes High Set Type / Contacts - CAG17 / 2 N/O S/R HighSet E/F Setting - 5 - 40 Amps HighSet O/C Setting - 12.5 - 100 Amps. Mounting - Flush Name Plate - RFG9126 903 Outline Diagram - MFJ 014 Wiring Diagram - MADZ821.32
GBCDG61EG102ZMCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Model No : CDG61EG102ZMCH CDG61/CAG17(MRK-III) APPLICATION - 3 O/C BURDEN - 3 VA C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R D.M.T - 3 SEC. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET O/C SETTING - 2.5 - 20 Amps. MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126 771 Outline drawing MFJ 014 Wiring Diagram MADZ821.31