Mode CPAP,S,T,ST,VGPS
Pressure 4-30 cm H2O
Trigger adjustment
Cycle adjustment
Sloop adjustment
Noise less than 32 dB(A)
YH-830 non-invasive ventilator has a double-layer design, with an independent humidifier and humidification function, the effect will be better. Its maximum inhalation pressure is 30cmH20, with ST and target tidal volume setting modes, and the breathing rate is 54 times/min. Each exhalation can perfectly trigger the ventilator, and it is easy to synchronize with breathing and can maintain normal inhalation intensity , Form a good synchronization with the large flow. It has relevant CE&FDA certification. The price is $9,000/set.
Model CPAP,S,T,ST,VGPS Pressure 4-30 cm H2O Trigger adjustment Cycle adjustment Sloop adjustment Noise less than 32 dB(A)
Mode:CPAP, S, T, ST, VGPS Pressure:4-30cm H2O Trigger adjustment Cycle adjustment Sloop adjustment Noise less than 32db(A) With pressure and flow waveform display Independent medical grade Humidifier
Have available PDF of the product features and manual
YH-830 non-invasive ventilator has a double-layer design, with an independent humidifier and humidification function, the effect will be better. Its maximum inhalation pressure is 30cmH20, with ST and target tidal volume setting modes, and the breathing rate is 54 times/min. Each exhalation can perfectly trigger the ventilator, and it is easy to synchronize with breathing and can maintain normal inhalation intensity , Form a good synchronization with the large flow. It has relevant CE&FDA certification. The price is $9,000/set.
Ventilator YH-830 bi-level PAP device CE certification and FDA certificate FOB Price USD 6.100/ Set Stock 300 units in stock today Payment term: T/T in advance. Delivery immediately after payment Technical parameters of YH-830 bi-level PAP device 1. Scope of application: For adult patients with ARDS, hypoventilation syndrome, for bi-level non-invasive ventilation in a hospital or home. 2. the main function: 1. Different treatment options can be provided according to patients' needs, from CPAP to S, T, S / T, VGPS five modes 2. Adjustable trigger sensitivity. 3. Real-time monitoring and recording of blood oxygen saturation. 4. alarm function. 5. Record function (SD card). 6. Maximum leak compensation function. 60L/min 7. With trolley, easy to move in the hospital 3. the key technical parameters: 1. Working mode: CPAP, S, T, ST, VGPS. 2. Ventilation parameters: 2.1 Inspiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.2 Expiratory pressure: 4-30 cmH2O (0.5 cmH2O interval) 2.3 Treatment pressure: 4-20 cmH2O (in CPAP mode, 0.5 cmH2O interval) 2.4 Delayed boost: 0-45 minutes (interval of 5 minutes) 2.5 Breathing frequency: 5-50 times / minute (interval 1 time / minute) 2.6 Breathing ratio: 10-70% (interval of 1%) 2.7 Rise time: 1-5 steps (1 step interval, 1 step rises fastest, 5 steps rises most slowly) 2.8 Inhalation sensitivity: 1-5 steps (1 step interval, 1st step triggers fastest, 5th step 1st step triggers slowest) 2.9 Exhalation sensitivity: 1-5 (1 interval, the 1st trigger is the fastest, 5th and 1st the slowest) 2.10 Tidal volume: 50-1500ml (effective in VGPS mode, interval 50ml) 3.VGPSï¼?same with AVAPS, can set Target tidal volumeï¼? 3.1 Maximum IPAP value adjustable range: 4-30 cmH2O 3.2 Adjustable range of minimum IPAP value: 4-30 cmH2O 3.3 EPAP value adjustable range: 4-30 cmH2O 3.4 Target Tidal Volume: 50-1500ml 4. Display range of monitoring setting parameters: 4.1 Respiratory waveform can be displayed; 4.2 Current mode: CPAP, S, T, ST, VGPS 4.3 Inspiratory pressure: 4-30 cmH2O 4.4 Expiratory pressure: 4-30 cmH2O 4.5 Breathing frequency: 5-50 times / minute 4.6 Breathing ratio: 10-70% 4.7 Air leakage: 20-99.9lpm 4.8 Tidal volume: 50-1500ml 4.9 minute ventilation: 0-50lpm 4.10 Blood oxygen saturation: 70-100% 4.11 Pulse rate: 25-250bpm 4.12 Delay boost: 0-45 minutes 6.Specifications 6.1 Weight: about 20kg including the trolley and the device 6.2 Operating temperature: 5-35 C 6.3 Relative humidity: 10% -90% 6.4 Power supply: input is AC 100-240V, 50-60Hz, 1.8A Max; output: DC 24V, 3.33A.
YH 830 For adult patients with ARDS, hyperventilation syndrome, for bi-level non-invasive ventilation in a hospital or home. Different treatment options can be provided according to patients needs, from CPAP to S,T,T,S/T, VGPS five modes.
YH 730 German brushless direct current blower, high efficiency ultra - silent core,owns 20,000 hors long life with 0.2 seconds rapid response.
SYS-JX100A is used in ICU rooms, emergency department, operating rooms and home. It can be used for child and adult patients. Features: Multiple functions can be used fora variety of occasions. The main parts adopt good-quality components. Which are accurate and reliable. With special self-test functions. A rechargeable built-in battery can be used for 8 hours. 5.7 LCD display, JogDial operation, simple and intuitive