"The AZM161 is designed for installations such as machines or robot cells where access to the hazard is to be controlled until a safe condition exists on the machine.
Features: thermoplastic enclosure, double-insulated, 2000N holding force, manual release emergency exit, 6 contacts.
Latching force: 30N
Positive break force: 20N
Positive break travel: 10mm
Clamping force: 2000N Fmax
Design of control element: Normally open contact (NO), Opener (NC)
Switching principle: Creep circuit element
Auxiliary contacts: 2
Safety contacts: 4
Rated control voltage Us: 24V a.c./d.c.
Power consumption: max 10W
Actuator contacts: 1 NO + 2 NC
Solenoid contacts: 1 NO + 2 NC (power to unlock)
Contact ratings:
AC-15: 4A 230V a.c.
DC-13: 2.5A 24V d.c.
Protection rating: IP67
Ambient temperature: -25 to +60°C
Dimensions: h130 x w90 x d30mm
Standards:
Mission time: 20 years
B10d value: 2 million"
"Design of Control Element: Normally open contact (NO), Opener (NC) Switching Principle: Creep circuit element Number of Auxiliary Contacts: 1 piece Number of Safety Contacts: 2 piece Rated Impulse Withstand Voltage : 6 kV Rated Insulation Voltage : 500 V Thermal Test Current: 10A Height (mm): 90 Width (mm): 52 Depth (mm): 30"
Supplier: Soda ash light / dense 99.2%
sodium bicarbonate
caustic soda flakes 99%
sodium sulphate anhydrous (ssa) 99%
sodium sulphite flakes (ssf) 60%
sodium metabisulphate
hydrogen peroxide (h2o2) 50%
formic acid 85%
glacial acetic acid
paraffin wax
liquid paraffin (white oil) lp 100
menthol crystal
fumed silica
deg (di ethylene glycol)
mono ethylene glycol (meg)
poly ethylene glycol (peg),
base oil 150n, bs 150, 600n
bitumen 60/70
rpo (rubber process oil)
lioh (lithium hydroxide)
hco (hydrogenated castor oil)
12 hsa (hydroxy stearic acid)
ferrous sulphate heptahydrate
additive for lubricating oil
aromatic chemicals
Services: Exporting of chemicals & other products
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Flat Cable M&P is able to support a full line of flat cable and flat ribbon cable for electronic applications. Providing both power and data transmissions, flat cables are mainly used for internal connections within the equipment. They are available in a wide range of configurations to accommodate different connection and data transmission requirements and the range of sizes of the equipment using the cables. Flat cables provide consistent performance due to their layout and the spacing between the cables and are lighter, thinner and more flexible than other cables. Features of Our Flat Cables & Wire * Flat, ribbon and twisted configurations, with different levels of flexibility. * Shielded or jacketed cable to reduce signal interference. * Range of pitches and pin configurations to accommodate the application requirements. * Easy to fasten with clamps, adhesive, and tape. We provide custom services, including marking, kitting and custom cable design to provide you with a custom solution for your cabling application. Contact us to find out more about Flat Cables and Wires.