The Philips Respironics Trilogy 202 is both a volume-control & pressure-control ventilator for invasive and noninvasive ventilation. Versatile breath delivery and setup options provide greater continuity of care.
Features
Leak compensation
The Trilogy 202 has the unique ability to compensate for leaks in both pressure and volume control modes. This allows the use of simpler passive circuits, which may save time and reduce costs. With one simple setting change, the Trilogy 202 supports either active or passive exhalation breathing circuits to accommodate changes in circuit preference.
Portable design for intra-hospital transport
The Trilogy 202 allows freedom of movement. With a 3-hour internal battery and optional 3-hour detachable battery, youll have sufficient power for intra-hospital transports with plenty of time for any delays or detours. It weighs only 5.6 kg and has an integrated carrying handle for convenient handling during intra-hospital transports.
Auto-Trak improves synchrony
The Auto-Trak algorithm improves patient-ventilator synchrony by adjusting to changing breathing patterns and dynamic leaks. The auto-adaptive triggering, cycling, and leak adjustments may help reduce the time clinicians spend adjusting thresholds and re-fitting masks.
Uniform settings to support hospital to home transition
Besides sharing a common user interface, all home and hospital Trilogy ventilators offer identical ventilation modes and breathing circuit settings. Home-bound patients receive the same finely tuned ventilatory support they received in the hospital. Stored data can be downloaded for review and evaluated to identify trends.
Leak compensated volume modes to improve consistency
Trilogy 202 offers all the conventional volume-control modes: AC, SIMV (with or without PS), and CV. The Trilogy 202 is designed to compensate for leaks in a volume control mode. This means consistent tidal volume delivery even during noninvasive or when cuff leaks are present.
The Respironics V60 ventilator is a microprocessor-controlled, bilevel positive airway pressure (BiPAP) ventilatory assist system that provides noninvasive positive pressure ventilation (NPPV) and invasive ventilatory support for spontaneously breathing adult and pediatric patients. Advanced NIV with our patented Auto-Trak technology Auto-Trak technology is designed to address the specific challenges of noninvasive ventilation. By providing auto-adaptive leak compensation, inspiratory triggering, and expiratory cycling, Auto-Trak delivers optimal synchrony in the face of dynamic leak and changing patient demand. Hospital modes and options include: AVAPS, PCV, CPAP with C-Flex, PPV and Auto-Trak Plus. Save time with automatic mask calibration We support your NIV efforts by increasing the speed and ease of treatment initiation. V60s pre-defined settings for Philips Respironics hospital masks help you save time. You select the setting, and the V60 automatically calibrates flow characteristics for better monitoring and therapy. Flexible, easy, upgradeable Designed to include pediatric use and equipped with several modes, the V60 allows you to meet the specific needs of your patients. The high-resolution touchscreen makes operation easy and facilitates waveform interpretation. The internal 6-hour battery enables intra-hospital transport. And, Respi-Link* allows you to upgrade via the internet.
Respironics Ventilator Circuit Corrugated Tube Adult Without Breathing Bag Single Patient Use UOM: 10/PK Product Number: 1073223 Manufacturer: Respironics
Kind : Philips Standard : Respironics Ventilator Certification : CE/FDA Unit Price (USDï¼? FOB : 45580 Aelivery Time : ready to shipping
Supplier: Disposable 3ply surgical mask, ffp2, ffp3, n95, surgical gown, isolation gown, ventilator vg 70 ventilator , philips trilogy ventilator, acm812a, cwh 3010, capacete versaflo m 106, lianhua qingwen capsule, icu respirator ventilator, protective clothing, surgical medical mask , forehead thermometer, covid 19 sars cov 2 igm antibody test kit (colloidalgold) covid 19 sars cov 2igg/igmantibodytestkit (colloidalgold)
Services: Clearing agent, shipping
NON-invasive Ventilator Brand: Philips Model: BiPAP S/T FDA 510k CERTIFICATE Certificate for Foreign Government Respironics Inc. EC certificate (Supporting people from Breath problem)
Product Name : COVID-19 SARS-CoV-2 IgM Antibody Test Kit Product Description : Material attachment is good. The shell of the detection card should be flat, the upper and lower covers should be closed evenly, and there should be no obviousgap.Thediluentshouldbeclearandfree offoreignmatter. 1.6 Size:thesizeofteststripshouldnotbelessthan2.5mm. 1.7 Liquidmigrationspeedshouldnotbelessthan10mm/min. 2.Minimumdetectionlimit TheminimumtestlimitreferenceproductsS1shouldbenegative,S2andS3shouldbepositive. 3.Negativecompliancerate 5copiesofnegativereferenceproductsof thetestcompanyshallbeallnegative,withanegativecompliancerateof100%. 4.Positivecompliancerate 5copiesofnegativereferenceproductsof thetestcompanyshallbeallpositive,withanegativecompliancerateof 100%. 5.Repeatability Test1copyoftheenterprisepositivereference,test10times,shouldbeconsistentcolor,arepositive. 6.Specificity 6.4 Cross Reaction: This product with vice influenza virus antibodies, influenza a virus, influenza b virus antibodies, pneumonia chlamydia, mycoplasma pneumoniae antibody, adenovirus antibody, respiratory syncytial virus antibody, hepatitisbsurfaceantibody,hepatitis cvirusantibody,treponemapallidumantibody,humanimmunodeficiencyvirus(HIV) antibodies,EBvirusantibody,measlesvirus,CMVantibodies,enterovirustype71,mumpsvirusantibody,varicella - zoster viruspositivesamples nocrossreaction. 6.5 Thereisnocross-reactionbetweenRF,ANAandAMA. 6.6 Interferingsubstance: (3) When bilirubin concentration =250 mol/L, hemoglobin content =9g/L, triglyceride content =15mmol/L,content of rheumatoid factor =80IU/mL, titer ofANA=1:240, anti-mitochondrial antibody (AMA) =80U/mL, content of mouse IgG=1000g/mL,therewillbenointerferencewiththetestresultsof thisproduct. (4) The commonly used antiviral drugs epiztin acid (=4mg/L), ribavirin (=40mg/L), interferon (=200mg/L), oseltamivir (=30mg/L), abidol (=40mg/L), levofloxacin (=200mg/L), azithromycin (=100mg/L), ceftriaxone (=400mg/L), meropenan(=200mg/L) havenointerferenceinthedetectionofthisproduct. 7. Hookeffect No hook effect was found in the test results of this product within the titer range of clinically positive samples of the novel coronavirusantibody. Price of product ( USD price or FOB price) : $4.23 Product origin : China Key Specifications/Special Features : CE FDA Hospital professional testing and use, family and individuals can not use Minimum Order Size and Packgaing details: MOQ:10000pieces 25pieces/box box size:15*14*6.5cm ,150g/box 100boxes /CTN,CTN Size 72*62*36cm 21KG(without lancet and alcohol cotton)
Product Description : Ventilation Modes VCV(A/C) PCV(A/C) PRVC SIMV(VCV)+PSV SIMV(PCV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV BIVENT+PSV NIV/CPAP NIV-T NIV-S/T Parameters Tidal Volume: 20~2000 ml Respiration Rate: 1~80 bpm Tinsp: 0.2~9 s Tslope: 0~2 s Tpause: 0~4 s I:E Ratio: 1:10~4:1 FiO2: 21%~100% Trigger Sensitivity: Pressure (-20~0 cmH2O, above PEEP) Flow (0.5~20 LPM) PEEP: 0~35 cmH2O Psupport: 0~70 cmH2O Pinsp: 5~70 cmH2O Special Procedures Apnea Ventilation Smart Suction Manual Breath Insp/ Exp Hold ETCO2 Measurement Nebulization Waveform Freeze Monitoring Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP Volume / Flow Value: Vti, Vte, MV, MVspont Time Value: ftotal,fspont, I:E Real Time Curves: Pressure-Time, Flow-Time, Volume-Time waveforms Pressure-Volume, Volume-Flow, Flow-Pressure loops • Gas Monitoring: FiO2, ETCO2 Calculated Values: Compliance(C) Resistance(R) MVleak RSBI WOB PEEPi Alarm Paw high / low MVe high / low Circuit disconnnect FiO2 high / low Inspiration / Expiratory tidal volume low High Respiration Rate Apnea AC Failure Nebulizer On Low Battery Air /O2 supply down High / Low PEEP Leakage out of range Occlusion Technical Data • Screen: 12?TFT color touch screen (detachable) Supply Gas: O2, 0.28~0.6 MPa Power Supply: AC100~240 V, 50 Hz/60 Hz Communication Interface: RS-232 Port, Nurse call Port, Ethernet Port Price of product ( USD price or FOB price) : $47922/pcs Product origin : Beijing, China Key Specifications/Special Features : In stock now; Delivery Time Shipment within 3 working days by air 360° Visible Alarm Lamp 12”TFT Detachable Touch Screen Ultra Quiet Turbine Inside Integrated Power Supply Solution Built-in Battery, With Extended Backup Option Minimum Order Size and Packgaing details :Minimum Order Size :1piece Dimension (WxDxH): 322 mm x 375 mm x 366 mm (Main Unit) 547 mm x 675 mm x 950 mm (Cart) Weight: 12.5 kg (Main Unit) 25 kg (Cart)
Product Name : COVID-19 SARS-CoV-2 IgG/Ig Manti body Test Kit (Colloidal Gold) with CE and FDA Product Description : shouldbenoobviousgap.The inner teststrip shouldbefirmlyattachedwithoutwaggle.Thediluentshouldbeclearandfreeof foreignmatter. 1.2 Size:thesizeoftheinnerstripshouldnotbelessthan2.5mm. 1.3 Liquidmigrationspeedshouldnotbelessthan10mm/min. 1.4 2. Minimum detection limit The minimum test limit reference products S1 should be negative, S2 and S3 should be positive. 3. Negative compliance rate:5 pieces of negative referenceproducts of the test companyshall be all negative, with a negative compliancerateof100%. 4.Positivecompliancerate:5pieces of positivereferenceproducts,eachreferencetestonetimes andshallbeallpositive,with apositivecompliancerateof 100%. 5.Repeatability:Test1pieceoftheenterprisepositivereference,testit10times,thecolor shouldbeconsistentandallpositive. 6.Specificity 6.1 Cross Reaction: This product do not cross-react with the positive specimens including vice influenza virus antibodies, influenza a virus, influenza b virus antibodies, pneumonia chlamydia, mycoplasma pneumoniae antibody, adenovirus antibody, respiratory syncytial virus antibody, hepatitis b surface antibody, hepatitis c virus antibody, treponema pallidum antibody,human immunodeficiencyvirus (HIV) antibodies, EBvirus antibody,measles virus,CMVantibodies, enterovirus type71,mumpsvirusantibody,varicella- zostervirus. 6.2 Thereisnocross-reactionbetweenRF,ANAandAMA. 6.3 Interferingsubstance: (1) When bilirubin concentration 250 mol/L, hemoglobin content 9g/L, triglyceride content 15mmol/L, content of rheumatoid factor 80IU/mL, titer ofANA1:240, anti-mitochondrial antibody (AMA) 80U/mL, content of mouse IgG1000g/mL,therewillbenointerferencewiththetestresultsofthisproduct. (2) The commonly used antiviral drugs epiztin acid (4mg/L), ribavirin (40mg/L), interferon (200mg/L), oseltamivir (30mg/L), abidol (40mg/L), levofloxacin (200mg/L), azithromycin (100mg/L), ceftriaxone (400mg/L), meropenan(200mg/L) hasnointerferenceinthedetectionofthisproduct. 7. Hook effect: No hook effect was found inthe test results of this product within the titer range of clinically positive samples ofthenovelcoronavirusantibody. 8. The minimum detection limit and reproducibility of 10 samples of clinically positive serum of COVID-19 novel coronavirus werestudied. Product origin : China Key Specifications/Special Features : CE FDA Hospital professional testing and use, family and individuals can not use Minimum Order Size and Packgaing details: MOQ:10000pieces 25pieces/box box size:15*14*6.5cm ,150g/box 100boxes /CTN CTN Size 72*62*36cm 21KG(without lancet and alcohol cotton)
Respironics Ventilator Circuit Corrugated Tube Adult Without Breathing Bag Single Patient Use Passive Circuit UOM: 10/PK Product Number: 1073227 Manufacturer: Respironics