1. Introduction
KP-S3000 three phase energy meter test bench is a new generation, high precision energy meter calibration equipment. It uses the advanced technology and electronic components available in 90 decade . The test bench can be operated from embedded keyboard or operated from PC software.
2. Feature and function
1) Equipped with electronic phantom load power source, assuring high stability, security and large output capacity.
2)Automatic adjustment of current measurement range. Fault self-detection in voltage amplifier and current amplifier.
3) Equipped with RS-232C interface, can be operated from software.
4) Test results can be saved to database, can be inquired from database and can be export to EXCEL file and then printed out.
GF312V2 portable three phase multifunction watt-hour meter calibrator on-site is the newest product produced by our company by widely visiting users and referring to the advantages of the same kind of products home and abroad. The measured part of the product adopts high speed A/D transmission to send DSP to conduct digital processing, which largely improves measured degree of accuracy and stability. Central processing part adopts 32-bit ARM embedded technology to make instrument interface novel, function abundant, operation distinct and easy, and performance steady. Class of accuracy: Class 0.02, 0.05 or 0.1, range from 12A/600V or 120A/600V, with comfort design, small size and light weight. The model GF312V2 watt-hour meter calibrator is suit for electric power departments, measuring and quality examining departments and electric lab to field use.
GF312B portable three phase energy meter calibrator with printer is used to calibrate three phase, single phase, active and reactive energy meters error. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line. It can measure wave distortion factor and 2nd to 64nd harmonic wave. GF312B calibrator is used for grid corporation of measurement and energy test center, metrological service of power supply bureau, national energy measurement of testing authorities.
The instrument GF312D1 is a precision 0.05% AC energy meter testing instrument, mainly used to test three phase energy meter error on site, measure all various of AC parameters and CT ratio & phase error, it is also as three phase reference energy meter in the laboratory. Mainly using test single phase or three phase meter error on site. GF312D1 energy meter calibrator is an ideal test tool for the metrological service of electricity power company.
INTRODUCTION The GF302D1 three phase portable energy meter test system consists of an integrated three phase current and voltage source(up to 500V/120A or 500V/20A) and built-in three-phase electronic reference standard of accuracy class 0.05%. Characteristic features of the GF302D1 are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 7 touch LCD-display. PARAMETERS Accuracy class 0.05%, 0.1% Power supply One Phase AC 100-265V, frequency 50/60Hz. AC Voltage output Range(U1,U2,U3) 57.7V, 100V, 220V, 380V or 69.3V, 120V, 240V, 480V( optional) Adjustment range (0-120)%RG(1) Adjust fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability 0.01%/120s Distortion 0.3% (Non-capacitive load) Output load each phase 30VA Measuring accuracy 0.05%RG AC Current output Range (I1, I2, I3 ) 200mA, 1A, 5A, 20A, 100A(optional) Adjustment range (0-120)%RG Adjustment fineness 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. Stability
INTRODUCTION: The instrument is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters. FEATURES Three phase active or reactive electricity energy meter. Calibrate three phase, single phase, and active or reactive meter error. Measure U(voltage) of three phase or single phase. Measure I(current) of three phase or single phase. Measure active power of three phase or single phase. Measure reactive power of three phase or single phase. Measure apparent power of three phase or single phase. Measure power factor of three phase or single phase. Measure phase angle between voltage and current. Measure frequency of power line. Display vector diagram. Display waveform of U and I. Analyze and display content of harmonic of U and I. Measure 2-64 harmonic of U, I. Store and display measured data. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp. Measure CT variable ratio. Measure the ratio or lag-angle of low-voltage transformer. Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD. Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity. Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.
The Portable Three Phase kWh Meter test equipment is used for grid corporation of measurement and energy test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high precision standard power source.
Product Introduction 3-phase energy meter calibrator introduction: HZ-3521 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. Product Characteristics 3-phase energy meter calibrator introduction: TKSX-3 handheld meter field calibrator is a measurement of electrical parameters power meter calibration wiring judged as one of the high-precision test instrument. 3-phase energy meter calibrator technical parameters: Input feature Voltage measuring range: 0 ~ 400V 57.7V 100V 220V 400V fourth gear automatic switching range. Current measuring range: 0 ~ 5A built-in transformer into 5A (CT) files. Clamp transformer for the 5A (small pliers) 25A (small pliers) 100A (the clamp) 500A (the clamp) 400A (tongs) 2000A (tongs) six stalls. (Including medium and large Clamp Meter is optional) Phase angle measuring range: 0 ~ 359.999 Frequency Measurement Range: 45 ~ 55Hz.
Product description: Three Phase Energy Meter Field Calibrator is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure various of AC parameters. Technical index: Electrical parameters Accuracy class 0.05%, 0.1% Resolution 6 TFT (640-480) Electrical parameters - continued Power supply 220V±10%, 50/60Hz Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh) Power line supply (U1, UN), 85V-265V 50/60Hz Communication port RS232 Test voltage Range 5-480V Error ±0.05% (30V-480V) ±0.1% (5V-30V) Harmonic 2nd-63st Test current Range (direct connection) 5mA-20A Error (direct connection) ±0.05% (100mA-20A) ±0.1% (10mA-100mA) Range (clamp CT) 10mA-3000A Error (camp CT) �±0.2% (100mA-100A) ±0.5% (100A-3000A) Harmonic 2nd-63st
Features: 1. Check the error of active and reactive of watt-hour meter at the same time, and meanwhile check the error of main and secondary meter in the same circuit. 2. Display the electrical constants such as: voltage, current, power, power factor, phase and frequency and etc. 3. Measure ct ratio, wave form display. 4. Measure 2-51 voltage and current harmonics. 5. Judge wrong wiring. 6. Measure the baud rate for multi-function energy meter and meter number reading. ¦ct secondary loading function. 8. Automatically correct the clamp error.