The traditional method of radiographic inspection for weld of oil and gas pipeline is to use radiographic source and film for transmission. However, with the improvement of quality control efficiency by the construction party, the method of film imaging can not meet the requirements of customers for efficiency. In addition, the film also has some problems, such as image processing, poor preservation, environmental pollution and so on.
Based on this situation, HATATEST independently developed the PT360 pipeline weld DR automatic detection system.
HATATEST Automatic DR Detection System for Pipeline Weld-PT360 is a kind of Automatic DR Detection robot who is similar with Transcan system in Russia, But HATATEST Automatic DR Detection System for Pipeline Weld-PT360 as the following highlights comparing with Russian Transcan :
-- Aluminum alloy chain spider, light and easy to carry
-- 400-1219 mm, any caliber can be used
-- Battery drive, maximum working time 12 hours
-- Software control (start and stop can be controlled manually by software, or automatic start and stop can be set)
-- Single-arm or double-wall transillumination
-- The whole installation process only takes 2 minutes
-- Real time imaging, greatly improved detection efficient
-- Image quality ISO 17636-2 Class B
-- Adjust the fixed device of the radiation source according to the customer's requirements, and match different radio sources
Supplier: Ndtquam industrial film, industrial digital radiography system, automatic dr detection system for pipeline weld pt360
High speed, high-capacity bench top, Medical/ Laboratory Centrifuge Machine, Microprocessor based  Heavy duty C.R.C. construction finished with powder coating. Noiseless Operation. Programmable RPM selection 500 to 6000 in intervals of 100 rpm. Digital timer 0-120 minutes. The machine is fitted with a well-balanced brushless motor with an electronic drive. The Electronic lid lock does not allow the lid to be opened when the machine is running. The motor is fitted with rpm sensor to monitor the rpm of the machine. The controller monitors the rpm of the machine and does not allow the motor to overspeed. The Machine has safety features for the detection of Imbalance and stops automatically. Warranty 3 years from the date of installation. 4 lines, 20 characters Jumbo LCD Display for set time, run time, set and run RPM, RCF.  50 programs can be stored in memory. Programmable Acceleration Time: 40-200 Sec and Deceleration Time: 40-200 Sec with advanced Coast Feature condition and opens automatically after centrifuge rotor stops.  Dynamic brake (automatic) .  Fast spin option.  Delta Industrial Automation VFD and SMPS (Make in India). The machine can run fixed angle rotors, swingout rotors, well plate rotors & microtube rotors. Stainless Steel 304-grade rust-free centrifugal bowl for extra protection and easy cleanin User-friendly control panel. The last test parameter recalls and displays automatically on LCD after resuming of Power
High speed, high-capacity bench top, Medical/ Laboratory Centrifuge Machine, Microprocessor based Heavy duty C.R.C. construction finished with powder coating. Noiseless Operation. Programmable RPM selection 500 to 6000 in intervals of 100 rpm. Digital timer 0-120 minutes. The machine is fitted with a well-balanced brushless motor with an electronic drive. The Electronic lid lock does not allow the lid to be opened when the machine is running. The motor is fitted with rpm sensor to monitor the rpm of the machine. The controller monitors the rpm of the machine and does not allow the motor to overspeed. The Machine has safety features for the detection of Imbalance and stops automatically. Warranty 3 years from the date of installation. 4 lines, 20 characters Jumbo LCD Display for set time, run time, set and run RPM, RCF. 50 programs can be stored in memory. Programmable Acceleration Time: 40-200 Sec and Deceleration Time: 40-200 Sec with advanced Coast Feature condition and opens automatically after centrifuge rotor stops. Dynamic brake (automatic) . Fast spin option. Delta Industrial Automation VFD and SMPS (Make in India). The machine can run fixed angle rotors, swingout rotors, well plate rotors & microtube rotors. Stainless Steel 304-grade rust-free centrifugal bowl for extra protection and easy cleanin User-friendly control panel.
Supplier: Ultrasound machine, x rays, laboratory equipment and consumables, covid kit and safety equipment. organic products and certification tomatoes and vegetables organic cotton and soyabean with trade certificates
1100 vp-p - 2a - 300 w Resistivity & ip Up to 10 adjustable ip windows 2d/3d resistivity tomography Multi - electrode arrays, ves, rp, sp Easy-control system Applications: Groundwater explorations, geotechnical investigations, measurements On dams and dikes, environmental studies, geological surveys, mineral Prospecting, archaeology and many others. Maint unit Weight : 3.5 kg Dimension : 13 x 17 x 39 cm
LAG-S200 Ladle Slag Detection System (Vibration Type) Overview The continuous casting vibration type ladle slag detection device is used to detect the slag content of the ladle nozzle in the steelmaking continuous casting process, so as to improve the cleanliness of the tundish molten steel and obtain the best yield of the ladle molten steel. The device adopts the principle of vibration detection. The LAG-S200 continuous casting ladle slag automatic detection system after many years of research with many scientific research institutes, and fully combined with the actual situation on site. It has a real field application value as a continuous casting ladle slag automatic detection system. The meaning of the system 1. Reduce the amount of tundish slag 2. Improve the purity of molten steel 3. Improve the life of the tundish 4. Reduce sliding nozzle erosion 5. Reduce nozzle blockage 6. Increase the number of continuous pouring furnaces 7. Reduce the amount of residual steel in the ladle when high-quality steel is casting 8. Improve the yield of molten steel 9. Improve the quality of continuous casting billets In order to improve the purity of the molten steel in the tundish, and improve the quality of the casting billet, especially to improve the quality of the billet in the transition section, and reduce the amount of residual steel in the high-quality ladle, and prolong the life of the tundish lining, and increase the number of continuous casting furnaces, necessary to detect and control the slag in the later stage of continuous casting ladle casting. The Working principle of the system The LAG-S200 continuous casting ladle slag automatic monitoring system detects the slag state during the pouring process by receiving the vibration signal of the mechanical operating arm of the ladle nozzle. In the process of molten steel pouring, when molten steel flows through the long nozzle and pours into the tundish, the molten steel impacts the wall of the long nozzle and causes the vibration of the mechanical operating arm used to support the long nozzle. Since the specific gravity of the steelmaking slag is less than half of the specific gravity of the molten steel, it floats on the surface of the molten steel, and the steelmaking slag appears when the molten steel is about to be all poured. At this time, due to the high viscosity and poor fluidity of light steelmaking slag, the impact force of the mixed flow of molten steel and steel slag on the wall of the long nozzle is quite different from that of pure molten steel. The system mainly monitors the ladle slag of the continuous casting by measuring and analyzing the vibration difference of the mechanical operating arm.
Box dimension - 1000mm x 750mm x 750mm Box Material - Stainless steel 304 L box with mirror finish inside brushed finished outside Acid resistant Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One Feed through electrical single phase 220 V - 16 A Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range. O2 = 20 l , H2O = 960 g Filtration HEPA : particles Glove Ports - Glove ports, 220mm diameter and should be O ring sealed Gloves Materials Gloves Piercan USA make Neoprene, or Butyl Dust filter - 0.3 micron Dust filter. HEPA Filter 0.3 micron HEPA, H13 or H14 Gas Purifier - Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent One each Shelves - Height Adjustable, Acrylic Stainless Steel shelves Three/ Yes Box Pressure Control -+15 mbar to -15mbar. Automatic pressure control. Yes Box Lamp -One front mounted fluorescent lamp one inside Yes Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process. Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. PLC Program Logi Control with integrated control with external display unit 10 One Yes Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10ï?Â2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/ per hour Service Support - Efficient service facilities with trained engineers at your place warranty One years comprehensive onsite warranty.
Box dimension 1000mm x 750mm x 750mm Box Material Stainless steel 304 L box with mirror finish inside brushed finished outside Acid resistant Box panel/window Openable Front window with polycarbonate an extra coating for chemical and scratch resistance One Feed through electrical single phase 220 V - 16 A Attainable purity < 100ppm H2O and < 500ppm O2 at complete pressure range. O2 = 20 l , H2O = 960 g Yes Filtration HEPA : particles Yes Glove Ports Glove ports, 220mm diameter and should be O ring sealed Gloves Materials Gloves Piercan USA make Neoprene, or Butyl Dust filter 0.3 micron Dust filter.HEPA Filter 0.3 micron HEPA, H13 or H14 Gas Purifier Molecular sieves, Activated Carbon, Charcoal chamber with high efficient O2 ,H2O adsorbent Shelves Height Adjustable, Acrylic Stainless Steel shelves Box Pressure Control +15 mbar to -15mbar. Automatic pressure control. Box Lamp One front mounted fluorescent lamp one inside Antechamber Type Cylindrical, 300 mm diameter, Length 600mm (inside dimensions) Material stainless steel, thickness 2.5mm Inside surface brushed finish Sliding tray stainless steel Doors SS thickness 10mm Door lock easy to operate, spindle lock Pressure gauge, monometer: analog display Vacuum/ Refill process. Regeneration Below 5% loss Complete automated or manual operation with foot switch Yes Sensors Solid state oxygen sensor with 0- 1000 ppm & Solid state moisture sensor with 0-500 ppm Auto purge PLC controlled via system control panel. Yes One Each PLC Program Logi Control with integrated control with external display unit 10â?? One Yes Vacuum Pump 740 mm HG with fittings (Optional) High Vacuum Pump: Oil sealed vacuum pump â?? 150 lpm,Vacuum level : 5x10 2mbar Type rotary vane pump, dual stage, Oil mist filter, Oil recirculation, Automatic gas ballast control, 10 m3/h Optional facility for automatically turning off the vacuum pump when the antechamber is not in use One 2Recirculation Pump Optional Re circulating purified gases pro rata basis 20m3/ per hour Service Support Efficient service facilities with trained engineers at your place warranty One years comprehensive onsite warranty.
Brief introduction: Lt-01 leak tester is designed for the examination of airproof property of packages, containers, bags, pipes. Lt-01 package air proof tester is widely used in food, beverage, pharmaceutical, daily chemical, electrical and electronic industries, etc. Lt-01 leakage tester complies with astm d3078 and gb/t 15171 standards. The leak detection system is composed of the mainframe and the vacuum chamber. A test sample is placed into a vacuum chamber with water and the air above water level is evacuated by a venturi vacuum ejector. A great pressure difference is created inside and outside the sample and any slight leakage can be observed and identified when the sample is inflated. Features Lt-01 leak tester uses vacuum ejector to generate stable vacuum environment. . The leak detection requires no electricity High leakage test efficiency Extra-thick perspex Different chamber sizes available No calibration needed No vacuum pump required Easy installation, start-up and operation Low maintenance Astm d3078 , gb/t 15171