NCS-TT108 smart temperature transmitter, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control. NCS-TT108 transmitter integrates abundant function blocks and realizes not only general measurement function but also complicated control strategy.
NCS-TT108 smart temperature transmitter supports eight-channel temperature sensor input. It applied to a variety of thermal resistance and thermocouple sensors and has wide range. Each channel support individually configure the sensor type and two-wire system and three-wire system connections of the thermal resistance. Eight channels are divided into four groups of temperature acquisition modules, with the security isolation between modules. Each temperature acquisition module has two temperature input channels.
NCS-TT108 smart temperature transmitter adopt PVC fire-retardant plastic shell, which can be installed in the control room. When it is required to be installed outdoors, outdoor Aluminum box, with a water-proof body and die-cast aluminum materials, must be selected.
NCS-TT108 uses digital technology. It has simple interface between field and control room, which reduces the expense of installation, operation and maintenance.
NCS-TT108 supports FF, and PA protocols. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.
Main features:
nflexibility
------Support many types of thermal resistance and thermocouple sensors
-------Thermal resistance supports 2/3 wiring connection mode
------Thermocouple can use cold end compensation function
nSupport many type of protocols
-----Support FF, PA protocols
Olympus CV-170 Video Processor and LED Light Source You can only treat what you can see. HD videoscopes have quickly become the standard in many ENT procedures due to the ability to examine mucosal patterns with greater clarity than traditional fiber or SD videoscopes. For the first time ever, HD laryngoscopy is now available to the patients who need it most at the point where it is most valuable: diagnostic laryngoscopy in the office. With LED light, HD scope support, and Narrow Band Imaging (NBI) built into one, compact box, the CV-170 provides physicians with exceptional diagnostic tools at an affordable price for any office.
NCS-PT105 series Smart Pressure Transmitter with advanced, mature, reliable 3151 capacitance sensors has been designed meticulously by combining advanced microprocessor technology and digital capacitance measurement technology. The powerful functions and high-speed computing capability of the microprocessor make it have excellent qualifications such as smart, high precision, high reliability, stable zero and so on. Its LCD can display many physical parameters (e.g. pressure, temperature, current and so on). It can realize the functions such as zero adjustment, range settings by key-press operation, and it is easy for field testing. NCS-PT105 series Smart Pressure Transmitter supports HART, FF, and PA protocol and can measure pressure, differential pressure, liquid level, flow, and other industrial parameters. It can be widely used in the petroleum, chemicals, electricity, and metallurgical industries, etc.. According to the type of measurable pressure: Model Pressure type NCS-PT105 SR Micro-differential pressure transmitter NCS-PT105 SG Gauge pressure transmitter NCS-PT105 SA Absolute pressure transmitter NCS-PT105 SD Differential pressure transmitter NCS-PT105 SH Differential pressure transmitter for high static pressure According to the protocol: Model Communication Protocol type NCS-PT105 H HART NCS-PT105 F FF H1 NCS-PT105 P PROFIBUS PA As a transitional communication protocol in fieldbus, HART protocol achieves digital transmission on the existing analog transmission lines, and is compatible with existing analog signal control system. Either FF H1or PROFIBUS PA is a new generation of digital communication protocol, used in field connection, and linking field devices. International Standard IEC61158-2 is used in physical layer. Therefore, either FF H1or PROFIBUS PA is fieldbus actually. As following, Smart Transmitter with HART protocol is named as HART Smart Transmitter; Smart Transmitter with FF H1 protocol is named as FF Smart Transmitter; Smart Transmitter with PROFIBUS PA protocol is named as PA Smart Transmitter, All of these (Transmitters with the three types of fieldbus protocol) are named as Smart Pressure Transmitters or Smart Transmitters. In addition, HART Smart Transmitter has passed explosion-proof certification from National Supervision and Inspection Center for Explosion Protection and Safety of Instrumentation (NEPSI).
Differential Transmitter In All Brand Emerson , Rosemount , Honeyweel , F+h , E+h Etc
Long battery life. By stand-by mode, battery lasts 1000h. Power switch remotely controllable. You can control on/off of rcs-50 by rcs-20t. Controllable range is nearly 100m. Original code between rcs-50 (transmitter) and rcs-20t (remote controller) avoid interference with the other unit if someone use it in the same area. bug detectors can not detect sleeping transmitter. (RCS-50) Size... 67 x 21 x 70 (73)mm / antenna °3 x 220mm Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 62h (6lr61, continuous transmission) / approx. 1000h (stand-by mode, no transmission) Available channels... Uhf-a, uhf-b Mic effective range... 15m from circle point. (RCS-50) Size... 42.5 x 21 x 112 (120) mm / rod antenna 20mm (shortened) - 460mm (extended) Weight... 162g (with alkaline batteries) / antenna 3g Power supply... "006p" (6f22/6lr61) 9v battery x 1 Battery life... Approx. 11h (6lr61, continuous transmission) Controlling rcs-50... Keep pressing button 5 seconds to turn on rcs-50. Same procedure to turn it off. Rcs-20t uses vhf frequency for remote control.
Display readout: -1999 . +9999 Input: DC 4 .. 20 mA Temperature / Pressure / Level Output: 4 ... 20 mA Accuracy: 0.2% F.S. IP rating: IP67
Supplier: Surveying gnss product, including digital sounder, gis data acquisition system, marine engineering application integrated system, GNSS receivers
Pressure Transmitter for Sandvik LH307/LH410
Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months. Intelligent Operation Method 1. LCD shows the output percentage or process pressure. Press the S key to select the display percentage or pressure.Press Z key to select pressure unit KPa or Mpa when displaying pressure. 2. Press S+Z key for 8 seconds, then release it at the same time, press Z key to set the zero value; Press the S key set the range. note: this function can only be triggered once an operation. 3. Adjustments to zeros or ranges may cause changes in the displayed options, i.e.The percentage being displayed becomes pressure or KPa becomes Mpa, etc. All these changes are shown only in the display, and have no effect on the internal parameters of the transmitter, pressure detection and current output. After adjusting the zero point and range, the S and Z keys can be used to select the desired percentage or pressure. 4. Zero-setting in field pressure-free state: 30 seconds after pressing S+Z key, the display shows zero time at the same time release the two keys, that is, zero. Simulated operation method 1.Zero-setting in pressure-free condition: The potentiometer with the word "zero" on the circuit board is adjusted to zero when it is displayed on the spot.(Note: Clockwise increase, counterclockwise decrease) 2.The potentiometer marked "range" on the circuit board can not be adjusted without standard pressure, so as to avoid the disorder of measurement range.
General Description The series of pressure transducers use imported high-quality pressure sensors and special integrated modules, through fine temperature, zero, full range, and non-linear compensation to achieve accurate measurement and transmission of pressure changes in liquid, gas, steam and other media. Technical Index Measuring medium: liquid, gas, steam Pressure range: -0.1MPA~0~60MPA Accuracy grade: ±0.2%FS, ±0.5%FS Stability: â?¤0.2%FS/year Temperature drift: â?¤0.02%FS/(range 0~70) Environment temperature: -20+85 Storage temperature: -20+85 Output signal: 4-20mA or 1-5VDC Supply voltage: 12-40VDC Allow overload: two times the quota voltage Explosiveproof grade: intrinsically safeia II C T6 flameproof dII C T6 Wetware material: 316 stainless steel and 1Gr18Ni9Ti Shell material: die casting alloy aluminum,surface epoxy spraying Pressure interface: M20X1.5 Weight: ordinary 0.75kg, with on-site instructions 1kg Structure Type x1 Connection x2x31 x4 The link mode and output signal of the compact tranmitter are as follows: Two-wire system: 1 Positive power supply 2 Negative power supply 3 Empty 4 Shell Three wire system: 1 positive power supply 2 Negative power supply (Negative sharing with signals) 3 Signal+ 4 Shell x5 The connection mode of aviation plug transmitter is as follows: Two-wire system(direct outlet type) 1 Red wire connection positive power supply 2 Black wire connection negative power supply Notice 1. All the supplied products are provided with product certificates and instructions, including product number, technical parameters, wiring diagram,factory date, etc. Please check carefully to avoid misuse. 2. Installation should check whether the field interface is connected to the product according to the connection mode and thread type of the product.The mouth is the same. If it is a threaded interface, it should be tightened slowly and sealed carefully. Torque can not be added directly to the transmitter shell, but only on the six sides of the pressure interface. 3. The wiring should be strictly in accordance with the instructions of our company. 4.This product is a precise instrument. It is forbidden to disassemble, colide,fall,throw hard or punch the drainage hole with a sharp instrument. 5. The transmitter can work by electricity, but the preheating output is stable for 30 seconds. 6. If any abnormality is found in use, the power supply should be turned off, the use should be stopped, the inspection should be carried out, or contact our technical department direct. 7.When transporting and storing, the original packaging should be restored and stored in a cool, dry and ventilated warehouse. 8.The quality assurance period is 12 months.