Plasma enhanced rotational PECVD system,
BTF-1200C-R-PECVD
Product descriptionï¼?
The whole experimental cavity is in the glow generation region, uniform equivalent glow, this technology is a good solution to the traditional plasma work instability, In this way, the range and intensity of ionization is 100 times of that of the traditional PECVD, to the uneven accumulation of materials .
Use a quartz tube of a special shape (thin middle between two ends) as a reaction chamber for chemical vapor deposition.The furnace tube can rotate 360 degrees, Quartz stopper on the inner wall of the tube can help stir-fry the powder material and sintered more evenly, and the furnace body can be tilted to the left and right at a large angle, which is convenient to feed in and out, and the inclined angle is adjustable from 0 to 35 degree.
Widely used in the preparation of graphene at low temperature and the carbon coating experiment of powder material.
Main parameter
Furnace
Max. Tem1200°C
Heating zone length 440mm
Constant zone length 200mm
Tem. control PID automatic control with 30 steps programmableï¼?Operation interface is 7 "industrial control computer
Tube Size Φ60*420+Φ100*360+Φ60*420mm
Furnace body inclination angle 0~35°ï¼?adjustableï¼?
Furnace tube rotation rate 3~13r/min
PE source
Signal frequency 13.56 MHz±0.005%
Power output range 0-500W
Max. reflection power 100W
RF output interface 50 Ω, N-type, female
Power stability â?¤5W
Gas supply system High precision mass Flowmeterï¼?Range optionalï¼?
Accuracy ±1.5%
Response accuracy ±0.2%
Response time Gas characteristicsï¼?1ï½?4sec
Electrical characteristics ï¼?10sec
Working pressure difference range 0.1ï½?0.5MPa
Max. pressure 3MPa
Connection Φ6mmDouble clasp stainless steel joint
Vacuum unit KF25 series bellows and manual stopper valves
Vacuum degree 10-1 pa
The value can be displayed intuitively by the digital display vacuum tester
Supplier: Ndfeb magnet, magnetic assembly, ferrite magnets, smco, halbach array magnet, surge protection device, gas discharge tube, lightning protection earthing system, spd, gdt, arrester, surge, lightning
Supplier: Low voltage power cables, mid voltage power cables, control cables, instrumentation and telecommunication cables, optical fiber cables, mine low voltage power cables, mine mid voltage power cables, rail transit communication cables, railway rolling stock cables, cables for use in photovoltaic systems, fireproof cable, low voltage power cables for shipboard and offshore, mid voltage cables for shipboard and offshore, control cables for shipboard and offshore, instrumentation and telecommunication cables for shipboard and offshore compensating extension cables and compensating cables, rubber sheathed cable, charging post cable, connecting cables for equipment, towline cables, high temperature resistant cable,esp power cable, (electrical submersible pump power cable), mining detection cable, logging cable, submarine power cable
Supplier: Food products, fruit and recreational plants, palm trees, generators, transformers, household electronics, ev charging stations, accumulators and battery systems, cooling appliances and frigotic systems for vehicles, furnitures (office and household types), copper tubes, powder metals for 3d printers, electrical equipment, defense products most notably drones (strategic /tactical), carrying boxes.
Services: Trade, sourcing and investment intelligence, supply chain development services, trade facilitation, inspection, operations support, full fledged trade/supply chain agency services
Buyer: High grade lead, zinc, antimony, manganese, iron ores.
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Fuji's servo system can be adapted to several types of motion control, from high-function like synchronization and interpolation to simple-function motion control like Point-to-Point positioning. Meanwhile, the improved auto-tuning function and new option like servo operator make the machine control with high-speed and high-accuracy be achieved more easily.
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C