VISION EXIM engaged in manufacturing and supply of wide range of materials / components for Power & Infrastructure industries.We have state of the art machineries, equipment and testing facilities for fabrication, shot blasting and painting to meet highest quality standards.
With skilled workforce availability and in house shot blasting & flow painting facility, we offer CORRUGATED FINWALL TANK as per customer requirements for transformer rating of 50 to 2500 kVA.
TRANSFORMER TANK FABRICATION
From 25KVA to 5000KVA power and from 6,3 KV to 36 KV voltage features, Trans-el produces Oil type, hermetic transformers or transformers with an oil expansion tank, Indoor and outdoor power and distribution Transformers
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
Applicable Standards: IS, IEC, ANSI, JIS, BS, DIN, ETC. TRANSFORMER OPTIONS: Cooling Tubes / Radiators / Corrugated Tanks Pole Mounted / Ground Mounted Free Breathing / Hermetically Sealed CSP / Non CSP Winding-Copper/Aluminium (Foil / Rectangular Wire / Round Wire) Fittings and Accessories, Cable Terminations etc.as required Standards: MUSKAAN’S transformers are designed and tested as per IS : 2026, BS - 171, IEC - 76 & IEC - 726. Vector Group: Transformers will be connected as per vector group reference Dyn11. Other vector groups can be offered as per specific requirements Terminal Arrangement: H. V. - Bare Bushings or Cable Box, L. V. - bare bushings or cable box. Disconnecting chambers can also be provided on both HV and LV Cable boxes. Temperature Rise MUSKAAN’S transformers are designed for a maximum temperature rise of 40 / 50 degree C of oil / winding. Lower temperature rise can be offered on request. Other Information Minimum Order Quantity: 1 Unit(s)
Supplier: Power transformer, silicon, steel, oil tank
Buyer: Wire magnetic
S11 Series 6kV-35kV power Transformer With Off Circuit Tap Changer,power oill transformer,high voltage step up transformer,distribution transformer The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission. Product Description The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission. S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior. Product Features Good Economic Performance The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series. Long Service Life Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil wont contact with air, so that extend the service life effectively. High Operation Reliability Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal. Small Installation Area S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
From 25KVA to 5000KVA power and from 6,3 KV to 36 KV voltage features, Trans-el produces Oil type, hermetic transformers or transformers with an oil expansion tank, Indoor and outdoor power and distribution Transformers.
Bharti's transformer are manufactured with standard rating & customer requirement, bhartiÆs transformer are designed & tested as per is2026. Our transformers are durable low capacitive, power saver and highly official. Product range of distribution & power transformer: Upto 100 kva, 1-phase, 11 kv or below Upto 3000 kva 11 & 33kv Upto 3000 kva oltc, 33kvor below Transformer design options: Single phase / three phase Indoor | outdoor Pole mounted / ground mounted Conventional type / hermetical fealed type Conventional radiator / corrugated radiator Copper / aluminum wound Fitting accessories as per requirement Depends
It is based upon advanced technologies introduced from abroad and the successful experiences of leading manufacturers both domestic and abroad. It conforms entirely with up-to-date National Standard GB1094.1~2-1996¡ê¬GB1094.3-2003 GB1094.5-2003 and International Standard IEC76 commended by international electrical engin- eering committee, and are proud of the following outstanding features: 1. Low loss, and significantly energy-saving. The average no-load loss is 35% lower than prescribed by National Standard GB/T 6451-2008. 2. The core laminations are made up from high-quality cold-rolled grain-oriented silicon steel sheets with chamfered joints and without punched holes, and are stacked without the upper yoke sheets in place, so that they are effectively improved no-load upper together with lower frame. 3. Zigzag directed flow of oil are provided within the windings, so that all parts of the windings can be cooled more evenly. 4. The regulating winding is a separate winding which apart from the high voltage main winding. In this way, total ampere-turn balance between windings ; and the axial electrodynamic force during short circuit can be reduced, thus upgrading the short circuit withstand capability of the transformer as a whole. 5. The windings of one phase are assembled into an integral phase block before placing into the core. 6. The winding manufacture, winding assembly core and winding assembly work are all proceed in totally closed clean department. 7. Core frames in the form of a flat plate are used for clamping the core, and are joined together by side beams. The core and coil assembly is fixed in the tank, being positioned against the tank at six sides rigidly, so that there can be no displacement of the assembly due to impacts during transport. 8. Transformer tanks are fabricated with steel plates wide enough so that there are no weld joints on each surface. The steel plates for tank walls are pressed into corrugated shape to increase mechanical strength and to reduce noise due to vibration of the tank wall. 9. Diaphragm membrane is provided within the conservator, preventing direct contact of oil with air, protecting the oil from aging, thereby prolonging the service life of oil. Magnetic oil-level gauge reflects correctly the oil level in conservator. Flat plate-type radiator can effectively cool down the transformer. 10. Reliably sealed, and fine machined for sealed surface. Used double gasket grooves in their jointing surface and kept tight with high quality gasket material. If required by the customer, the upper and lower part of the tank can also be welded tight. 11. High quality paint is applied as surface finish of the tank and exposed steel parts, after shot-blasting and pretreatment, thus ensuring a durable life and glossy surface. 12. Quality assurance rules are also observed for all insulating parts, from raw material to final assembly. Strict regulations are observed for drying, wrapping and storage, preventing the absorption of moisture, swelling, and deformation. 13. Main components Because of good relationship and long-term co-corporation with all well-known sub-suppliers, we can meet the requirements of customers with whatever types of components they wish to have. fumigation wooden case