Model
Item HBW-03
Nominal cooling capacity kcal/h 7405
Kw 8.61
Input power kw 3.05
Power supply 3pH~380V 50Hz
Refrigerant type R407C
Type of control capillary
Compressor type hermetic scroll
Power (kw) 2.68
Condenser type shell and tube
Cooling water flow(m3/h) 1.77
Inlet and outlet pipe diameter(inch) 1-1/2
Evaporator type tank with coil
Chilled fluid flow(m3/h) 1.48
Volume(L) 60
Inlet and outlet pipe diameter(inch) 1
Pump power(kw) 0.37
Lift(m) 25
Safety protection compressor over temperature, over current, high and low pressure, over temperature, flow switch, phase sequence, phase-missing, exhaust overheating
Weight kg 130
Dimension mm 890*500*840.
Model
Item AW-05
Nominal cooling capacity kcal/h 13158
Kw 15.3
Input power kw 5.2
Power supply 3PH~380V 50HZ
Refrigerant type R22
Type of control capillary
Compressor type hermetic scroll
Power (kw) 4.55
Condenser type shell and tube
Cooling water flow (m3/h) 3.5
Inlet and outlet pipe diameter (inch) 1-1/2
Evaporator type tank with coil
Chilled fluid flow(m3/h) 2.63
Volume (L) 60
Inlet and outlet pipe diameter (inch) 1
Pump power (kw) 0.75
Lift(m) 20
Safety protection compressor over temperature, over current, high and low pressure, phase sequence, phase-missing
Weight : 150 kgs.
Dimension mm 890*500*840.
Item Unit model
AGS-060WSL
Refrigerant -10degree kW 94.1
-20degree 64.2
-30degree 40.1
Power 3φ 380V 50Hz
Total input power kW 45.4
Compressor Type Semi hermetic screw
Power kw 45.4
Refrigerant R22/R404A
Start-up model Y-Triangle
Evaporator Type Shell and Tube
Chilled fluid flow m³ /h 29.5
Condenser Type Shell and Tube
Cooling water flow m³ /h 23.9
Inlet/outlet pipe diameter Evaporator Inch 3"
Condenser Inch 3"
Drain out port Inch 1"
Dimension Length(L) mm 2130
Width (W) mm 855
Height(H) mm 1540
Weight Net weight kg 950
Running weight kg 1060
Note:
1. Nominal cooling capacity calculated according to:
The chilled fluid is the 60% Ethylene Glycol aqueous solutions.
Inlet/outlet cooling water temperature: 32degree/37degree
2. Working condition:
The temperature range of chilled fluid is from -5degree to -30degree
Temperature difference between inlet and outlet chilled fluid is from
2.5degree to 10degree
The temperature range of cooling water from 22degree to 37degree
Temperature difference between inlet and outlet cooling water is from 3.5degree to 10degree.
Model
Item AL-15W
Nominal cooling capacity kcal/h 35948
Kw 41.8
Input power kw 16.42
Power supply 3pH~380V 50Hz
Refrigerant type R22
Type of control thermostatic expansion valve
Compressor type hermetic scroll(piston)
Power(kw) 13.72
Condenser type finned copper tube + low noise outer rotor fan
Cooling air flow(m3/h) 15000
Evaporator type tank with coil
Chilled fluid flow(m3/h) 7.2
Volume(L) 270
Inlet and outlet pipe diameter (inch) 2
Drain(inch) 1
Pump power (kw) 1.5
Lift(m) 26
Flow switch On >16L/min, Off <10L/min
Safety protection compressor over temperature, over current, high and low pressure, over temperature, flow Switch, phase sequence, phase-missing, exhaust overheating.
Weight kg 750
Dimension mm 1800*990*1680.
Note: 1. Nominal cooling capacity is according to:
Inlet chilled fluid temperature: 12degree
Outlet chilled fluid temperature: 7degree
Inlet cooling air temperature: 30degree
Outlet cooling air temperature: 35degree
2. Working range:
The temperature range of chilled fluid is from 5degree to 35degree;
Temperature difference between inlet and outlet chilled fluid is from 3degree to 8degree.
The machine should be used while the ambient temperature at or below 35degree.
Model AM-3 W
Heating medium Water
Temperature range degree 30~100degree
Heating capacity KW 3
Power supply Volt 3Phase-380V-50Hz
Pump Power KW 0.37KW
Max. Flow rate L/min 42L/min
Max. Pressure kg/cm2 2.8kg/cm2
Cooling method Direct cooling
Pipe diameter Heating pipe diameter lnch 3/8
Cooling pipe diameter lnch 1/2
Dimension mm 650x300x500
Weight kg 55
Note: For the water transfer medium MTC, the water pressure should ≥ 2kgf/cm2 when it connect with running water.