Feature
It is a ventilation device for infant with novel structure and good performance, and chooses opening ventilation mode with high frequency and little tidle volume, so the airway pressure is low.If you want to know more.
A. The tidal air can letout with constant pressure, constant current or accurately adjustable flow.
B. Opening ventilation, opening intubation makes it not need casing bag, little resistance as expiration is suited for the ventilation management of infant.
C. Evident effectiveness of treating ards can be shown with inserting small tube and jetting oxygen through nasal vestibule, which is secure and doesn't cause pressure wound easily.
D. Peep and humidifier volume can be adjusted accurately.
E. Alarm system with sound and light when no oxygen, poor of electric quantity or low airway positive pressure.
F. Heated humidifier can be used for good effectiveness of humidifying.
G. Accumulator jar, it can be used while being charged and can last for more than four hours.
Specifications
Frequency10+150 breaths/min
I/e ratio1:1, 1:1.5+ 1:3 and inverse ratio
Pressure atomizer rate>=6ml/h
Process ventilationt=10min,
Proi:f(150):f(35)=7:3
Proii:f(35):f(150)=7:3
Storage battery4ah, automatic charge when 12v
Sigh:3breaths/min
Alarm:alarm when battery voltage is lower than 11v, alarm lasts 6 seconds if no oxygen, alarm with audible signals and flashing light when the airway pressure is over 0.8kpa
Cpap0+0.5kpa
Peep0+0.20kpa
Oxygen concentration adjustable:21%-90%
Jetting volume rangeo+600ml/time
Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure);hfjv+peep(positive end-expiratory pressure), hfjv+sigh(sigh), process ventilation i and process ventilation ii.
Standard packaging.
Feature
It is widely used for clinical salvaging and revival also is a dedicated device used for respiration salvaging on emergency ambulance.
A. An opening system is designed to avoid leakage of airway, when ventilating, the intubations may have no casing bag. Little tube may be used for ventilation when resistance of expiration is small, so that mucose won't be hurt easily.
B. Airway is open during ventilation, suction and ventilation can be done synchronously, so good effectiveness of oxygen combination can be shown without inspiration and expiration synchronizing.
C. Lower airway pressure is good to increase blood discharge and decrease encephal pressure.
D. Suction device, its driving negative pressure is adjustable.
E. Accumulator jar, it can be used continuously for not less than four hours after being charged.
F. The system disposes completely with laryngoscope, inlet intubation, catheter of tracheotomy, nasal prongs tube, and air tube etc.
Specifications
Frequency: 10 150 breaths/min
I/e ratio1:1, 1:1.51:3 and inverse ratio
Sigh:6breaths/min,
Cpapf1.5kpaff
Suction negative pressure:-0.050mpa
Driving pressure 00.15mpa
Constant volume ventilation: t=10min, i/e=1:1.5
Adults:f(100):f(20)=7:3, tidal volume=550ml/time, driving pressure=0.06mpa
Children:f(100):f(20)=7:3, tidal volume=350ml/time, driving pressure=0.04mpa
Storage battery:4ah, automatic charge when 12v
Most jetting volume:f1400ml/time
Oxygen concentration adjustable:40%-90%
Alarm: alarm when battery pressure is lower than 11v; alarm when the oxygen pressure is lower than 0.01mpa; alarm with sound and light when no gas
Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh;constant volume ventilation.
Standard packing.
Feature
A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, at the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out co2.
B. Jet oxygen feeding is supported by pressure when inspiration and secure certain peep effect when feeding oxygen, so as to reach good effectiveness of oxygen feeding.
C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged.
D. Alarm system with sound and light when lack of electric quantity or airway pressure.
E. 300cg chooses digital display of import pressure sensor.
F. 300cg has three kinds of airway limited pressure alarm for adult, child and infant.
G. The device disposes pressure humidifier which has good humidigying effectiveness.
Specifications
Power supply:ac220v+22v 50hz+1hz
I/e ratio1:1, 1:1.5+ 1:3 and 3:1
Driving pressure 0+0.15mpa
Sigh:6breaths/min, i/e=1:4
Pressure regulator limit:0.30mpa
Cpapnot less than 1kpa
Oxygen concentration adjustable:40%-90%
Process ventilationt=10min, infinite recursion
Proi:f(150):f(35)=7:3
Proii:f(35):f(150)=7:3
Alarm:alarm with light and sound for no gas or no power or airway pressure is over
Inner battery:4ah 12v
Ventilation mode:hfjv(high frequency jet ventilation);cpap(continuous positive airway pressure), hfjv+sigh(sigh); process ventilation i and process ventilation ii, manual control mode.
Standard packing
A. When the ventilation technique with open high frequency and low humidify volume is adopted, the airway pressure is low with little effect of oxygen compound is good and the oxygen partial pressure can be increased rapidly. While the one with regular frequency and great humidify volume is adopted, CO2 can be ejected easily.
B. Convenient connecting, it can be connected through the nasal and endotracheal tube.
C. The ventilation mode with high frequency and low humidify volume will not easily produce pressure hurt.
D. The effect of oxygen dispersion is so good that the tested beastie can stand for a long time.
E. Adjustable oxygen concentration, the ventilation mode with continuous oxygen stream and good humidifying effect can ensure beastie to respire independently.
F. Be fit for manual ventilation test for monkey, rabbit, dog etc.
G. Configured with multiform ventilation conduit for beastles or connected with gas source, in addition.
Specifications·ª
Frequency:8f+150 breaths/min
I/E ratio·ª1:1f+1:3 and inverse ratio
Driving Pressure ·ª0f+0.08MPa
Gas source: High-pressure oxygen source or air compredsor. The input pressure is not more than 0.16MPa
High-pressure gas source:0.16MPa
Output Limit of reductor: not less than 0.16MPa
Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),Manual Control Mode.
Feature:
A. The device adopts impulse jet oxygen feeding technique with great flow rate of oxygen feeding in a shot while, when feeding oxygen, it adopts change mode major in reflux and many kinds of gas flow mechanism such as convection, laminar flow, sheet flow and so on concurrently, which is good to increase partial pressure of oxygen rapidly, At the same time fluctuation of thorax caused by increasing oxygen flow into airway is good to let out CO2.
B. Jet oxygen feeding is supported by pressure when inspiration and secure certain PEEP effect when feeding oxygen, So as to reach good effectiveness of oxygen feeding.
C. Accumulator jar, it can be used while being charged and can last for four hours after having been charged.
D. Alarm system with sound and light when lack of electric quantity or airway pressure.
E. 300CG chooses digital display of import pressure sensor.
F. 300CG has three kinds of airway limited pressure alarm for adult, child and infant.
G. The device disposes pressure humidifier which has good humidigying effectiveness.
Specifications
Power supply:AC220V+22V 50HZ+1HZ
I/E ratio·ª1:1,1:1.5+ 1:3 and 3:1
Driving Pressure ·ª0+0.15MPa
SIGH:6breaths/min, I/E=1:4
Pressure Regulator Limit:0.30MPa
CPAP·ªnot less than 1KPa
Oxygen Concentration Adjustable:40%-90%
Process Ventilation·ªT=10min,Infinite recursion
ProI:f(150):f(35)=7:3
ProII:f(35):f(150)=7:3
Alarm:Alarm with light and sound for no gas or no power or airway pressure is over
Inner Battery:4Ah 12V
Ventilation Mode:HFJV(High Frequency Jet Ventilation);CPAP(Continuous positive airway pressure),HFJV+SIGH(Sigh); Process ventilation I and Process ventilation II, Manual Control Mode.