Control panel
One installing code
One (user) main code (can create duress code automatically)
8 gradable user codes
Periodic test
Offer testing report to alarm center automatically
Peripheral eequipment
With voice module
Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port
Events record
50 event records
Memory when power is cut
Digital voice module rv2006v
1 piece of voice message, time lasts 20s
Follow-me number is assignable
Timing function
Auto daily arming
Auto daily test report
Monitoring function
Trouble data can be displayed on keypad, and also can be transmited to central station
Spare battery in low power
Expansion module of power supply battery in low power
Siren circuit in trouble
Phone line failure
Loss of ac
Loss of auxiliary power
System clock is not set
Tamper prevention
Fire alarm circuit in trouble
Installation
All expansion modules can be connected to the system by 4-line
The distance is up to 300m between module and control panel
Technical data
Transformer: 16.5vac 40va
Standby bettery: 12v4ah/ 12v7ah
Auxiliary powerfg350ma
Switch lockfg250ma
Siren/bell sound outputfg750ma
Led keypadf]rp205kp
3 keypad emergency zones: panic([1]+[2]), fire([4]+[5]), special emergency([7]+[8])
Led indicates the user functions and the installer programing
Key-press with audible feedback
Trouble display
Led indication: alarm, power, armedfadisarmed, bypass, ready, tamper
Backlight keys
Tamper is supervised
Alarm by duress code
Easy to use hot-keys for simple bypassing and not-ready zones display
One button for quick arming
One button for quick perimeter arming
Up to 4 led keypads can be connected
Mainboardf]rp205mb
5 zones of mainboard
Special zones: zone-5 is fire zone
Can be parted to 2 divisions11 types of programmable zones, 7 types of voice formats
Zone terminal: nc, no, single end with resistor (2.2kf±[)
Responding to various events
Time to supervise is programmable
Switch for power output
Linkage output: nc, no, locked, or pulse
Programmable output: 70ma
50 events records
8 groups of 4 gradable codes
Switch output: 250ma
Built-in siren driver: 750ma (max)
Built-in digital clock
Daily test report
Disarm/arm report
4 led keypads can be connected to control panel, 4-line connection
Built-in digital communicator
Attached digital communicator, compatible to contract idfa4+2
2 central station phone numbers
4 follow-me phone numbers
Lcd keypad (rp208kcl)
Display of 32 characters in two lines
3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8]
Menu indicates the user functions and the installer programing
Key-press with audible feedback
System condition display
Trouble display
Led indication: alarm, power, armed, disarmed, bypass, ready, tamper
User information is displayed on screen (except password)
Lcd backlight
Tamper is supervised
Alarm by duress code
Easy to use hot-keys for simple bypassing and not-ready zones display
One button for quick arming
One button for quick perimeter arming
Alarm memory display
System trouble display
Up to 4 lcd keypads can be connected
Mainboardf]rp208mbf^
Zone terminal resistor (2.2kf±[)
8 zones of mainboard
Expandable wired zone
Special zones: zone-5 is fire zone, zone-6 is tamper zone
11 types of programmable zones, 7 types of voice formats
Zone terminal: nc, no, single end with resistor
Programmable output: 70ma
Expandable to 4 large current output: 3a
50 event records
8 groups of 4 gradable codes
Switch output: 250ma
Built-in siren driver: 750ma max
Built-in digital clock
Daily test report
Disarm/arm report
4 lcd keypads can be connected to control panel
Circuit responding time of each zone can be set as 10ms, 500ms or 1s
Mainboard has 7 types of fire alarm bell voice driver
Connectible with four 1.5v 12a power supply expansion boards
Mainboard has one 70ma programmable open circuit collector
Connectible with 3a c-type programmble relay
The distance is up to 1500m between module and control panel
Siren voice output
Siren voice type is programmble
Current outputfg750ma(max)
Auxiliary power output
Auxiliary power output: 400ma
Built-in digital communicator
Attached digital communicator, compatible with contract idfa4+2
4 follow-me phone numbers
2 central station numbers
Code
One installing code
One (user) main code (can create duress code automatically)
8 gradable user codes
Periodic test
Offer testing report to alarm center automatically
Peripheral equipment
With voice module
Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port
Power supply output expansion module eps
Connect with system by 4-line
Provide 2.5a, 12v power to other modules and siren
Complete supervision of power supply condition, including battery, ac, siren circuit and auxiliary power output
Digital voice module rv2006v
1 piece of voice message, time lasts 20s
Follow-me number is assignable
Timing function
Auto daily arm
Auto daily test report
Disarm/arm rreport at window
Monitoring function
Trouble data can be displayed on keypad, and also can be transmited to central station
Spare battery in low power
Expansion module of power supply battery in low power
Siren circuit in trouble
Phone line failure
Loss of ac
Loss of auxiliary power
System clock is not set
Line communication is blocked
Tamper prevention
Fire alarm circuit in trouble
Installation
All expansion modules can be connected to the system by 4-line
The distance is up to 1500m between module and control panel
Technical data
Transformer 16.5vac 40va
Spare battery 12v4ah
Auxiliary power supply 350ma
Switch lock 250ma
Siren 750ma
Lcd keypads (rp248kcl)
Display of two lines and 32 characters
3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8]
Menu indicates the user functions and the installer programing
Key-press with audible feedback
System condition display
Trouble display
Led indication: alarm, power, armed, disarmed, bypass, ready, tamper
User information is displayed on screen (except for password)
Lcd backlight
Tamper is supervised
Alarm by duress code
Easy to use hot-keys for simple bypassing and not-ready zones display
One button for quick arming
One button for quick perimeter arming
Alarm memory display
System trouble display
Up to 4 lcd keypads can be connected
Mainboardf]rp248mbf^
Zone terminal resistor (2.2k+[)
8 zones on mainboard
Expandable up to 72 programmable zones
Special zones: zone-5 is fire zone, zone-6 is tamper zone
Can be parted to 8 divisions
11 types of programmable zones, 7 types of voice formats
Zone terminal: nc, no, single end with resistor
Programmable output: 70ma
Expandable to 32 large current output: 3a
50 event records
8 groups of 4 gradable codes
Switch output: 250ma
Built-in siren driver: 750ma max
Built-in digital clock
Daily test report
Function of end calling
Disarm/arm report
4 lcd keypads can be connected to control panel
Programmble voice for the siren output
Current outputfg750ma(max)
Auxiliary power output: 400ma
Mainboard has 7 types of fire alarm bell voice drivers
Connectible with four 1.5v 12a power supply expansion boards
Mainboard has one 70ma programmable open circuit collector
Connectible with 32 c-type programmble relays of 3a
Circuit responding time of each zone can be set as 10ms, 500ms or 1s
The distance is up to 1500m between module and control panel
Built-in digital communicator
Attached digital communicator, compatible with contract idfa4+2
2 central station numbers
4 follow-me phone numbers
Code
One installer code
One (user) main code (can create duress code automatically)
8 gradable user codes
Periodic test
Offer testing report to alarm center automatically
Peripheral equipment
Expandable function of 32 lines relay output
Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port
Rs232 port
Expandable zone board
8 zones expansion module ez8
8 zones wiring expansion module
Power supply output of switch lock
Zones terminal: nc, no, single end with resistor (2.2k+[)
Circuit responding time of each zone can be set as 10ms, 500ms or 1s
4-line connection, and easy for installation
8 zones wireless expansion module ew8
Wireless expansion module
Time to supervise is programmable
Monitoring of emitter in low power
Tamper of emitter is supervised
Indication of interfering signal
Wireless detector is supported
Verifying code by cycle
4 program output expansion module e04
4 lines programmable output(3a)
Output: nc, no, locked or pulse
Responding to various events
Xto module supports x-10 agreement
Power supply output expansion module (rp248eps)
Connect with 5 modules by 4-line
Provide 2.0a, 12v power to other module and siren
Complete supervision of power supply condition, including battery, ac, siren circuit and auxiliary power output
Built-in siren driver
Tamper is supervised
Memory when power is cut
Digital voice module rv2006v
1 piece of voice message, time lasts 20s
Follow-me number is assignable
Timing function
Auto daily arm
Auto daily test report
Disarm/arm report at window
Monitoring function
Trouble data can be displayed on keypad, and also can be transmited to central station
Spare battery in low power
Expansion module of power suplly battery in low power
Siren circuit in trouble
Power expansion module of siren circuit in trouble
Lcd keypads (rp248kcl)
Display of two lines and 32 characters
3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8]
Menu indicates the user functions and the installer programing
Key-press with audible feedback
System condition display
Trouble display
Led indication: alarm, power, armed, disarmed, bypass, ready, tamper
User information is displayed on screen (except for password)
Lcd backlight
Tamper is supervised
Alarm by duress code
Easy to use hot-keys for simple bypassing and not-ready zones display
One button for quick arming
One button for quick perimeter arming
Alarm memory display
System trouble display
Up to 4 lcd keypads can be connected
Mainboard¡]rp248mb¡^
Zone terminal resistor (2.2k£[)
8 zones on mainboard
Expandable up to 72 programmable zones
Special zones: zone-5 is fire zone, zone-6 is tamper zone
Can be parted to 8 divisions
11 types of programmable zones, 7 types of voice formats
Zone terminal: nc, no, single end with resistor
Programmable output: 70ma
Expandable to 32 large current output: 3a
50 event records
8 groups of 4 gradable codes
Switch output: 250ma
Built-in siren driver: 750ma max
Built-in digital clock
Daily test report
Function of end calling
Disarm/arm report
4 lcd keypads can be connected to control panel
Programmble voice for the siren output
Current output¡g750ma(max)
Auxiliary power output: 400ma
Mainboard has 7 types of fire alarm bell voice drivers
Connectible with four 1.5v 12a power supply expansion boards
Mainboard has one 70ma programmable open circuit collector
Connectible with 32 c-type programmble relays of 3a
Circuit responding time of each zone can be set as 10ms, 500ms or 1s
The distance is up to 1500m between module and control panel
Built-in digital communicator
Attached digital communicator, compatible with contract id¡a4+2
2 central station numbers
4 follow-me phone numbers
PIR motion detectors
Rk210pr can be equipped with ra93 swivel bracket for ceiling, wall or corner mounting.
Main features:
Coverage is 10m
Dual passive infrared detective technology
True temperature compensation
Dual polarity pulse count is adjustable
Resist interference of white light
Power consumption is low
Professional optical pigmented lenses
Installed on wall, ceiling or corner mounting
Convenient for installation
Pulse count is selectable
Resist fluorescent interference
Memory and form-c relay
Smart and elegant design is ideal selection for residential installations
Specification:
Working voltage: 9-16vdc
Working current: 12ma
Contact of alarm: nc, 12vdc, 100ma max
Contact of tamper: nc, 12vdc, 100ma max
Time to alarm: 2.2s
Time to warm-up: 2 minutes
Rfi characteristic: 22v/m, 10mhz ~ 1ghz
Working temperature: -5ºc ~ 50ºc
Storage temperature: -20ºc ~ 55ºc
Size: 89f-52f-39mm
Height of installation: 2.3m
Suitable swivel bracket: ra93