The digestion vessel is divided into two inner and outer tanks. The inner lining is made of Telfon material and the outer tank is made of 304 stainless steel to prevent tank explosion.
Specially used for digestion experiments of insoluble samples and volatile elements in samples.
#samplepreparation #digestionvessel #geochemistry #labware
PTFE tweezers have serrations at the end, increasing friction and making sample extraction easier; The rear end is made of stainless steel material, which reduces pressing resistance and makes it more flexible to use while also increasing its service life.
#tweezers #samplepreparation #sampledigestion
Supports custom processing of various styles of PFA accessories.Suitable for semiconductor photovoltaic equipment, fluid equipment, as well as instruments such as chromatography, spectroscopy, mass spectrometry, etc
#semiconductor #ICPMS #PFAValue #teflon
DBF series adopts imported PFA anticorrosive coating, which can be customized. To meet the physical, chemical, biological, environmental protection, pharmaceutical, food, beverage, teaching, scientific research and other different industries of chemical laboratory needs. Imported PFA coating clean, never rust. Anticorrosive cast aluminum heating plate heating fast; Panel and control box can be made into components, acid mist will not corrode the components in the control box, can handle multiple samples at the same time, no cross contamination; Customized time setting function, segmented temperature control; The exposed part of the power cord is wrapped with PFA tubes to further prevent the corrosion of the components by acid gas
Full specifications can be customized: 30-10000ml; resistant to strong acids and alkalis, high temperature resistance: -200~+250; smooth surface, easy to clean; made of Teflon resin, not easy to break.
#teflon #labware #sampling
Professionally customize PTFE/PFA developing wafer basket and etching wafer basket. Made of polytetrafluoroethylene, acid and alkali resistant, not suitable for breakage, and can be used for a long time.
Can add a base and put in a PTFE rotor to enhance liquid fluidity. Can be customized according to wafer size and quantity. Used for etching and development in semiconductor processes.
High-purity PFA, one-piece molding without welding. 1.5/15/30ml available, tube diameter and tube length can be customized. Resistant to strong acids and alkalis, with a rotatable stand for easy placement.
PTFE filters are mainly used for filtering small amounts of solutions, removing particulate pollutants, clarifying liquids, sterilizing filtration, etc. As filters themselves can replace filter membranes, they are widely used in laboratory liquid chromatography pre filtration detection.
High temperature resistance: can be used for a long time in high temperature environments, without deformation and aging due to temperature changes.
Efficient filtration performance: can filter small particles and impurities, ensuring the purity and safety of liquids or gases; High filtration accuracy, high filtration efficiency, can be used continuously for a long time, reducing the frequency and cost of replacement and maintenance.
#filter #Liquidpurification #PTFElabware #filtermembrane
Systems with different specifications have different acid production rates:
1L acid production rate: 50ml/1h
2L acid production rate: 70ml/1h
4L acid production rate: 90ml/1h
Our acid purification system is specially designed to reduce metal impurities in organic solutions. Generally, for an acid with a metal impurity content of 10 ppb, after one purification, the metal impurity content can be reduced to about 0.01 ppb.
#ICPMS #acidpurification
Perfluorinated digestion vessel for use in ovens
Mainly used to digest insoluble substances in a high temperature, high pressure, closed strong acid or strong alkali environment.#digestionvessel #analyticalchemistry #samplepreparation
Digestion tube holder for CEM 110ml
The holder can be placed in a fumehood to hold digestion tubes.
Can withstand corrosion from strong acids and alkalis.
There are handles at both ends of the holder to facilitate the transfer of the digestion tube.
Different sizes of holders can be customized according to different brands and specifications of digestion tubes.
#microwavedigestiontube #digestionvesselholder #Cleanlaboratory #MARSXpress
PFA conical triangular flasks are generally used in titration experiments.
To prevent the titration solution from splashing out of the bottle and causing experimental errors when dropped, place the bottle on a magnetic stirrer and stir.
You can grip the bottleneck with your hand and shake it with your wrist, stirring evenly. Containing reactants, quantitative analysis, reflux heating, its appearance makes it suitable for these tasks.
In addition to adding a stopper to the long neck, it can also slow down the loss during heating and prevent the overflow of chemicals.
#Erlenmeyerflask #Conicalflask #reactionvessel
It is used for the digestion of geological, geological and mineral samples and the dissolution of medium and low pressure samples, supporting ICP-MS/ICP-OES analysis and other micro analysis experiments. There are three designs: U-shaped bottom, flat bottom and V-shaped bottom. Applicable to my male perforation digester.
The appearance is translucent, the inner wall is smooth, no water hanging, easy to clean; 200 260 (it is better not to exceed 150 under closed conditions); Thread interface, good sealing, no leakage; Resistance to insulation Metal element blank value is low; Opening can be autoclaved; Non-toxic: Cover and body can be numbered
The surface adopts imported PFA polytetrafluoroethylene anticorrosive non-stick coating treatment, strong corrosion resistance, resistance to 260 high temperature. To prevent acid and acid gas corrosion of the instrument; Room temperature to 260, can work continuously for 48 hours, thermal efficiency is more than 5 times higher than the flat electric heating plate, lower carbon;Three-dimensional heating, small temperature difference between holes, so that each part of the sample heat evenly, prevent heat loss, faster digestion, easy to use, long service life; PID temperature control digital display, temperature control accuracy 1, voltage :220V/50Hz
ppt level sampling bottle, which can be used for pin-type sampling, has excellent air tightness, is made of Telfon (PFA) material, can store standard substances for a long time, and is resistant to strong corrosion.
#Wetelectronicchemicals #semiconductor #Electronicgradebottle #Highpurityreagents #PFAvials #labware #geochemistry
Teflon multi-neck flask, condenser tubeï¼?connected by PFA tube. Can be used for distillation and purification of fluoride. Supports custom fittings and valves.
Multiple specifications available: 10, 25, 50, 100, 250, 500, 1000ml.
Compared with glass, it is more resistant to falling and less likely to break, and has a longer service life. The inner wall is smooth and non-stick.
PP, PFA, glass, PTFE, etc. support customization, optional specifications . PTFE digestion tubes are available with a variety of reflux covers, and most other materials are threaded sealing covers.
The cover and body are made of high-purity imported PFA material and do not contain other impurities. Resistant to strong acids and alkalis, the utensils can be put into a cleaning tank and soaked in acid for cleaning.
#acidcleaning #teflon #labware #icpms
25/55/75/100/110ml can be customized, and PFA or TFM materials are optional. Independently produced, the price is more favorable. It can be used with all types of CEM instruments without conflict.
#digestiontube
It can be used with separation funnels, stirring plugs, condenser tubes and other vessels to form a distillation and condensation reaction device for the purification of substances. Available in 250ml-3000ml, the number of necks can be customized. Undertake various PFA welding, mold opening and other services.
#teflon #flask #Roundbottomedflask #labware #semiconductor #newenergy
Available in 30-5000ml, the bottle body and cap are made of high-purity PFA material, resistant to strong corrosion and high temperature: -200~+260. Can store standard chemicals for a long time without leaking.
#reagentbottle #teflon #labware #samplingvials
Composed of multiple PFA tubes, PFA valves, PFAVials and two isotope ion exchange columns. Use with digestion instrument for heating. Support customization of various PFA tube combinations.
Use acid steam to clean the utensils in countercurrent to clean more thoroughly and avoid cross-contamination.Can be placed on a hotplate to clean the PFA vials and labware by heated soaking in soap solution or acids.All wetted parts are molded from high purity PFA.
#teflon #acidcleaningsystem #labware #pfavials #geochemistry
Can be externally connected to a gas washing bottle absorption device to form a reaction device; the bottle cap and bottle body are made of high-purity PFA material, without other impurities; resistant to strong acids and alkali, and high temperature: -200~+260â??; multiple specifications available custom made.
Multiple specifications available: 5/10/25/30...1000/2000ml;
1. Corrosion-resistant, especially resistant to hydrofluoric acid.
2. Low background, no dissolution or precipitation.
3. Anti-fall and durable.
#cylinder #labware #teflon #electronicgrade
1.Application: Heating water bath, oil bath, etc.
2. Operating temperature: -200â??~+260â??.
3. Features: The inner wall is smooth, corrosion-resistant, and the metal element blank value is low.
4. Main use: Reactor between liquid and solid or liquid.
#labware #digestionvessel #labware #flask #teflon
1. Suitable for semiconductor analysis, trace analysis, isotope analysis and other analytical laboratories that have strict requirements on the use of utensils.
2. Good sealing, no leakage, can be stored for a long time, and has a high reuse rate.
3. The metal element blank value is low, the content of lead, uranium, etc. is
Teflon centrifuge tubes have tube caps to prevent sample leakage, especially for radioactive and highly corrosive sample experiments. It can also prevent the centrifuge tube from deforming.
#centrifugetube #samplepreparation #labware
Used for the connection of laboratory equipment in the chemical industry, semiconductor, pharmaceutical industry and other industries. Connect pipes of different diameters to achieve medium transportation and flow control.
It can be used as a gas absorption bottle to connect to various reaction devices. The bottle contains Teflon filter balls. Multiple units can be connected in series as gas filtering devices to make the gas cleaner. 30-4000ml multiple specifications available from stock.
#teflon #labware #PFABottle #gaswashbottle #gasabsorption
The bottle cap and bottle body are both made of high-purity PFA material; there are three bottom designs: flat, round, and conical; Can be used with a hotplate for sample digestion.
#PFAVials
The specifications and styles of the reaction bottles can be customized according to the needs; PFA hoses can be connected to other reaction vessels as absorption bottles and collection bottles; the neck of the bottle cap adopts a thread sealing design to ensure the airtightness of the container.
#samplepreparation #ICPMS #PFAbottle #labware #geochemistry
Teflon balls can be added to the tube to increase the reflux area; it can be directly connected to a flask and constant pressure dropping funnel to form a condensation reflux device; common specifications: 250, 300, 350, 500ml, larger specifications can be customized.
#distillationcondensation #Refluxdevice #teflon #flask #labware
It is often used in trace analysis, ultra-trace analysis, ICP-MS analysis, isotope analysis and other research industries; it can separate HF, the inner wall has no adhesion or adsorption to solvents, and can be completely drained.
#ICPMS #separatoryfunnel #traceanalysis #isotopeanalysis
The PTFE threaded cap can be customized with a variety of interfaces, and can be connected to joints, PFA conduits, separatory funnels, etc. to form a reaction device. PFA Jar is available in various specifications: 60, 90, 120, 150, 180, 240ml...4,6L.
#reactionbottle #PFAJar #digestionvessel
Mobile: +86-153 6614 0844
Wechat/Whatsapp: +86-153 6614 0844
Mail: ClairBZH@gmail.com
A variety of specifications are available, and external necks and valves can be customized as required. Below the device are connected a Buchner funnel, a filter bottle and other suction filtration devices. PTFE material is resistant to strong acids and alkalis and high temperatures.
#Reactor #Stirringdevice #Suctionfiltration #reactiondevice#teflon
The PFA ion exchange column has a Teflon sieve plate and is more durable without welding. This storage turntable effectively solves the placement problem.
#Isotopeanalysis #ICPMS#resinseparation #teflon
Mobile: +86-153 6614 0844
Wechat/Whatsapp: +86-153 6614 0844
Mail: ClairBZH@gmail.com
It has excellent chemical resistance and can withstand strong acids and alkalis, such as nitric acid, aqua regia, etc. The position of the lower outlet valve and the liquid level gauge can be customized. High temperature resistance: -200 to +250. Both 30L and 50L can be customized.
Can be matched with: PTFE stirring paddle, thermometer, condenser tube, heating jacket, air inlet, feeding port, discharge valve, etc.
#reactor #reactionvessel #Petrochemical #Buchnerfunnel
A 1/4-inch conduit can be connected to the lid to connect other reaction devices. PFA reaction bottles can store standard reagents for a long time, and large-capacity reaction bottles can be used for cleaning containers.
#reactionbottle #Vialscleaningvessel #samplepreparation #teflonlabware
PFA gas washing bottles are widely used. Prepare gas, collect gas, remove gas impurities, test gas, measure gas. In experimental devices with flammable gas sources, gas wash bottles can also function as safety bottles.
Used for the preparation of ultrapure acids in trace analysis, it can meet the low detection limit requirements of ICP-OES and ICP-MS and provide laboratory-grade ultrapure acids for demanding analytical applications, such as HNO3, HCL, HF and other commonly used laboratories. acid.
#aciddistillation #ultrahighpurityacid #subboiling #acidpurification
Molded from chemically resistant perfluoroalkoxy resin, this beaker features a thick-wall design suitable for continuous use in the laboratory.Suitable for trace and ultra-trace analysis and isotope analysis laboratories.
#beaker #teflonlabware #samplepreparation #ICPMS
Can meet the low detection limit requirements of ICP-OES and ICP-MS and provide laboratory-grade ultrapure acid for demanding analysis applications. The main body of the equipment is made of high-purity PTFE and PFA, and the container in contact with the acid reagent is made of imported PFA material. , lower background, no corrosion, no pollution, can handle HNO3, HCL, HF and other commonly used acids in laboratories.
Experiments have shown that after a single distillation of an acid with a metal impurity content of about 10PPB, the metal impurity content can be reduced to about 0.01PPB. If the acid requirements are higher, the purification times can be increased.
It is often used to extract high-purity acid in Ultra clean laboratories, trace analysis laboratories, geochemistry, marine systems, geology and minerals, geological brigade, polysilicon, materials and other industries.
#Geochemistry #ICPMS #acidpreparation #acidpurification #traceanalysis
The surface is treated with imported high-purity PFA anti-corrosion non-stick coating. It is a professional experimental hotplate for sample heating, digestion, evaporation, boiling and acid removal.#samplepreparation
The PFA separatory funnel is mainly used in solid-liquid or liquid-liquid reaction experiments to control the amount of liquid added and the reaction rate, as well as material separation and purification, and to separate the two immiscible liquids formed after extraction.
#separatoryfunnel #Solublepolytetrafluoroethylene #ICPMS #ICPOES #traceanalysis
PFA, perfluoroalkoxy resin, is a special polymer material. In laboratories, PFA gas washing bottles are often used for gas purification and drying. Because its inner wall is smooth and difficult to adsorb gas molecules, it can effectively remove impurities and moisture in the gas and ensure the accuracy of experimental results.
In petrochemical, semiconductor manufacturing, environmental protection and other industries, PFA gas washing bottles are widely used for gas pretreatment to ensure gas quality during the production process. In addition, PFA gas washing bottles are often used for gas storage and transportation. Due to its material characteristics, PFA gas washing bottles can maintain good performance in high or low temperature environments, ensuring gas stability and safety.
#reactionbottle #gaswashingbottle #gascleaning #gaspretreatment
The threaded sealing cap prevents liquid from leaking and can store high-purity reagents and standard samples in a sealed manner for a long time.
It is widely used for digestion of new semiconductor material experimental samples and sample dissolution at medium and low pressures, supporting trace analysis experiments such as ICP-MS/ICP-OES analysis.
Mainly used for gas reaction, washing and collection. The bottle cap can be customized with a 1/4 interface connection hose as a reaction device for hydrogen fluoride experiments. It has excellent chemical resistance and can withstand temperatures from -200 to +260. The interface adopts thread sealing design for better sealing.
#reactionbottle #teflon #PFAtube #reactiondevice
The surface is treated with imported high-quality PFA anti-corrosion non-stick coating. It is a professional experimental electric hot plate for sample heating, digestion, evaporation, boiling and acid removal.
The heating bracket can be removed when not needed.
Application:
1. Experimental electric heating plates are used in soil heavy metal fields such as: sediments, agricultural fields, plant fields, sludge, farms, etc.;
2. Electric heating plates are used in heavy metal fields such as sewage treatment plants, water plants, etc.
3. Electric heating plates are used in food heavy metal fields such as: fruits, seafood, meat, candy, vegetables, seeds, etc.;
4. Electric heating plates are used in pharmaceutical heavy metal fields such as pharmaceutical factories, nutritional products, health products, etc.
#samplepreparation #hotplate #Splitdesign #PFAvials
Graphite digestion instrument wet digestion to process the sample, adds acid to the sample, and accelerates the chemical reaction through heating to convert the test components into a liquid state, which is then further analyzed by elemental analysis instruments. For example , in the analysis of ores, soil, food, etc., it is often necessary to use a graphite digester to digest organic matter samples into a liquid state for further analysis.
#digestioninstrument #samplepreparation #ICPMS
Trace Analysis Low Background Value PFA Sampling Spoon
PFA is a plastic material with excellent acid and alkali resistance and high temperature stability. In the semiconductor manufacturing process, PFA sampling spoons are often used to handle some high-purity and chemically active solutions or materials.
PFA sampling spoon plays a role in solving the acid and alkali resistance and high temperature stability requirements in the semiconductor manufacturing process. They help ensure the handling of high-purity materials and maintain the quality of semiconductor devices.
PFA three-neck flask, the middle neck and bottle body are integrally formed, which is not fragile and more durable. Resistant to strong acids and alkalis, the surface is smooth and does not adhere to samples.
The main purpose:
(1) Reactor between liquid and solid or liquid;
(2) Assemble the gas reaction generator (normal temperature, heating);
(3) Distill or fractionate liquids (using a flask with a branch tube, also called a distillation flask);
#reactor #distillation #Flask #reactiondevice
Made of high-purity soluble polytetrafluoroethylene, resistant to high temperatures and strong corrosion.
Transparent appearance,integrated molding without welding, more sturdy and durable.
Application:
Applied in film-forming experiments, sample liquid leakage, etc.
It can be placed on an electric heating plate for direct heating, or used for oven drying, transfer and handling of corrosive samples in the laboratory, to prevent the scattering of corrosive liquids.
#labtray #squareplate #ICPMS #samplepreparation
The teflon series reaction bottle contains a PTFE filter ball and a threaded sealing design at the bottle mouth to ensure the sealing of the reaction vessel. Connect other reaction vessels through PFA conduits to form a hydrogen fluoride reaction device, and the PFA valve can control the flow of liquid or gas.
#reactionvessel #reactor #teflonlabware #teflonvalve
The Telfon Buchner funnel can replace the ceramic Buchner funnel to avoid fragmentation. The Buchner funnel made of polytetrafluoroethylene material has strong corrosion resistance and can be filtered using vacuum or negative pressure suction. It can also be matched with a filter bottle and used for vacuum filtration of crystals or coarse particle precipitation in inorganic preparation. It can prevent the splashing of corrosive solvents.
Application:
1. Matched with suction bottles, used for vacuum filtration of crystals or coarse particle precipitation in inorganic preparation;
2. When the precipitation is low, use a small funnel in conjunction with a filter tube.
1. Wet digestion treatment plan for lithium batteries: determination of nickel cobalt lithium material (determination of nickel, cobalt, and manganese content in nickel cobalt manganese oxide lithium material for lithium-ion batteries)
2. Determination of matrix metal impurities in electronic grade polycrystalline silicon: iron, chromium, nickel, copper, zinc, sodium.
Wet digestion treatment scheme for lithium batteries - determination of iron content
A combination of graphite digestion instrument or aluminum alloy anti-corrosion electric heating plate+PFA or PTFE beaker can be used for digestion
After digestion, transfer to a PFA or FEP volumetric flask for constant volume, dilute with water, and finally use analytical instruments such as ICP-MS to measure elemental data
PFA material has excellent physical and chemical properties, and can withstand highly corrosive media such as oxidants, acids, alkalis, hydrofluoric acid, chlorine gas, and solvents, maintaining the long-term stable operation of valves, spring tubes, etc. Accept various customized welding requirements for PFA pipes.
#laboratoryvalve #semiconductor #catheter #teflon
Mainly used in industries such as semiconductors, polysilicon, new energy, new materials, solar energy, etc., it plays an important role in chemical laboratories and the processing of solar silicon wafers.
Features: High temperature and low temperature resistance: PTFE flower baskets have excellent high and low temperature resistance, and can be used in the temperature range of -200 to+250 without deformation or melting. Corrosion resistance: Due to the exceptionally strong carbon fluorine bonds in its molecular structure, polytetrafluoroethylene hardly reacts with any chemical substances, thus being able to resist strong acids.
PFA (fluororesin) volumetric flasks can meet A-level volumetric standards and are designed with integrated molding without welding. The bottle mouth is sealed with threads to ensure its sealing performance and prevent liquid leakage. Can tolerate organic solutions such as strong acids and bases. Can be used for reagent adjustment in water quality detection and ICP analysis.
#volumetricflask #labbottle #labware #ICPMS
Used for cleaning 20 * 20mm and 15 * 20mm wafers, can be placed in reaction containers such as flasks for reaction. The size of the wafer holder can be customized according to the size of the flask mouth. Mainly used for silicon wafer pre treatment in industries such as semiconductors, polysilicon, new energy, new materials, and solar energy
#semiconductor #wafercleaning #reactor #wafercassette
PFA beakers have excellent chemical corrosion resistance and heat stability, and are commonly used as reaction vessels to dissolve small amounts of substances in strong acid or alkaline solutions at room temperature or under heating conditions.
Molded from chemically resistant perfluoroalkoxy resin and featuring a heavy-wall design, these beakers are ideal for continual lab usage.
#beakers #labware #samplepreparation #Geochemistry #traceanalysis #reactionvessel
The neck is equipped with a threaded sealing cover, which can connect 1/4 of the pipe to other reaction devices. The bottom valve of the bottle body can be welded, and various specifications can be customized. Clean and pollution-free, resistant to strong acids and alkalis.
#reactionbottle #Perfluoroalkoxyresin #labware #semiconductor #Gaswashing
The PFA headspace injection bottle, as a high-purity sample vessel for gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS), plays a crucial role in precise analysis due to its excellent chemical inertness, low adsorption, and high temperature resistance.
Application in high-precision analysis:
-Detection of toxic and harmful gases and volatile organic compounds in environmental monitoring;
-Inspection of residual solvents in food packaging materials in food safety;
-Determination of solvent residues in raw materials and finished drugs in drug analysis;
-Accurate measurement of light and trace components in petrochemical products.
#Injectionbottle #PFAVessel #Environmentaltesting #Highprecisionanalysis #Foodtesting #Chemicalpharmaceuticals #Traceanalysis
Customizable specifications and sizes can be made based on the outer tank of the digestion container
Can be used for sample pretreatment in atomic absorption spectroscopy and plasma emission analysis; It can also be used for low-dose synthetic reactions; Sample pre-treatment is performed in chemical analysis methods such as gas phase, liquid phase, plasma spectral mass spectrometry, atomic absorption, and atomic fluorescence.
#digestionvessel #PTFEliner #reactor #Heavymetaldetection #samplepretreatment
Compared to PTFE material, TFM has some improved characteristics. For example, with lower background values, it has better resistance to deformation, permeability, and recoverability under high temperature and pressure.
We can produce various models of microwave digestion containers using molds, which can be matched with original instruments and have no size errors.
Selected materials, no added recycled materials, clean processing environment, optimized processing technology, ensuring low background and non polluting samples.
#digestionvessel #Milestone #Moldproduction #Microwavedigestioninstrument #samplepretreatment
Sample pretreatment experiments suitable for analyzing dozens of elements in geological and mineral samples, such as Mo, Ba, V, Si, Se, Li, Ga, Fe, Mg, Zn, Hg, K, etc.
Strong corrosion resistance and high temperature resistance; Covers and bodies can be digitally numbered without confusion; The design of a V-shaped bottom makes it more convenient to collect a small amount of samples; The U-shaped bottom design is suitable for the detection of physical and chemical exploration samples.
Application: Sample analysis and digestion experiments in geology, geology, geochemistry, soil microorganisms, etc
Molded from chemically resistant perfluoroalkoxy resin and featuring a heavy-wall design, these beakers are ideal for continual lab usage.
Commonly used as a reaction vessel for preparing strong acid and alkali solutions, dissolved substances, and smaller amounts of substances at room temperature or under heating conditions.
Suitable for trace and ultra trace analysis, isotope analysis laboratories, etc.
#Beaker #wetdigestion #samplepreparation #traceanalysis #ICPMS
PFA pipes have excellent chemical corrosion resistance, are resistant to all chemicals, have the lowest friction coefficient among plastics, and have excellent electrical performance. Suitable for producing corrosion-resistant parts, wear reducing and wear-resistant parts, seals, insulation parts and medical device parts, insulation layers for high-temperature wires and cables, anti-corrosion equipment, sealing materials, pump valve liners, and chemical containers.
In the field of chemistry, PFA is used as a lining material in reactors, distillation towers, storage tanks, and pipeline fittings.
#PFAtube #labware #semiconductor
PFA gas absorption devices are commonly used for the absorption and purification of inert gases, such as hydrogen, fluorine, etc. They are composed of three PFA reaction tank style bottles in series, which can effectively remove impurity gases, improve the purity of the required gas, and ensure the smooth progress of experiments. They are applied in semiconductor analysis, new materials and new energy, lithium battery and other experimental testing and analysis.
It can be used with PFA valves and electronic flow meters that are resistant to strong corrosion, making it easy to control reaction speed. According to experimental requirements, organic glass or PVFE racks can be selected.
#gasabsorptiondevice #Seriesreactiondevice #washingbottle #Gaspurification #Lithiumbatteryanalysis #semiconductor
Application:
(1) Reactors between liquids and solids or liquids;
(2) Assemble a gas reaction generator (at room temperature, heated);
(3) Distillation or fractional distillation of liquids (also known as distillation flasks with branch tubes);
Standard neck openings of 17, 19, and 24mm, each with a plug.
Detachable for cleaning, with smooth inner walls; The lid and body, as well as the necks and lids, are threaded connections for easy disassembly and cleaning.
PFA cleaning tank is a container used for soaking and cleaning semiconductor wafers and chip flower baskets, and can also be used for soaking and cleaning of trace analysis laboratory PTFE containers (such as microwave digestion tanks, reagent bottles, beakers, crucibles, etc.).
The design of integrated molding can avoid liquid leakage.
The PFA cover can prevent dust pollution.
The PFA cleaning tank size can be customized to meet different experimental needs.
#labwarecleaning #cleaningtank #semiconductor #wafercleaning #traceanalysis
PFA gas washing bottle is a vessel used to remove impurities from gases. It involves bubbling and absorbing impure gases through a selected suitable liquid medium (dissolution or chemical reaction), in order to wash away impurities and achieve the goal of purifying gases. When designing, the surroundings of the PTFE balls are covered with small holes. In general, long catheters come in and short catheters come out.
#gaspurification #reactionbottle #PFAvessel
PFA material is resistant to strong corrosive solutions such as strong acids and alkalis.
The bottle cap adopts a threaded sealing design, without the need for a bottle stopper, with no liquid leakage, and can be sealed for long-term storage of high-purity reagents and standard samples.
Widely used for the digestion and medium low pressure dissolution of semiconductor new material experimental samples, supporting trace analysis experiments such as ICP-MS/ICP-OES analysis.
#Reactionvessel # traceanalysis # SeriesReactiondevice
1. The inner and outer walls of the bottle are smooth, and there is no easy liquid residue at the bottle mouth and inner wall;
2. The sealing of the bottle mouth and cap is good, without the need for a cork, and the liquid does not leak; Capable of long-term sealed storage of high-purity reagents and standard samples
3. It is resistant to high temperatures and can be used at temperatures ranging from -200 to+260 â??.
4. Widely used for the digestion of semiconductor new material experimental samples and medium and low pressure dissolution, supporting trace analysis experiments such as ICP-MS/ICP-OES analysis.
#reactionvessel #Extractionelement #ICPMS #traceanalysis
Main uses
Reactors between liquids and solids or liquids;
Assemble a gas reaction generator (at room temperature, heated);
Commonly used for substance extraction under atmospheric pressure.
The neck opening is available in standard sizes of 17, 19, and 24mm, with each standard opening equipped with a plug.
Detachable for cleaning, with smooth inner walls.
Operating temperature: -200 â??~+260 â??.
The cover and body are sealed with threads, ensuring excellent sealing performance and no liquid leakage.
#Reactionvessel # metalextraction # Organicsolution # traceanalysis
Application:
1. Wafer protection: The PFA wafer clamp can protect the wafer from external pollution, damage, or electrostatic interference, ensuring the quality and stability of the wafer.
2. Cleaning and treatment: PFA wafer clamps can be used for wafer cleaning, treatment, and heat treatment processes to ensure the surface cleanliness and treatment effect of the wafer.
3. Convenient transfer: The PFA wafer clamp can perfectly avoid the problem of wafer fragmentation caused by the inability to fix during the transfer of a single wafer.
PFA wafer clamp can be customized in size according to the specifications of the wafer; PFA material is highly pure and resistant to strong corrosion, with extremely low dissolution and precipitation.
#wafertransfer #waferclamp #semiconductor #wafers
PFA condenser tube is mainly a consumable material that uses the principle of heat exchange to cool and condense condensed gases into liquids. A reflux or distillation tube used in organic chemical experiments.
Optional specifications: 250, 300, 350, 500ml
#Condensation #Reflow #teflon #Heatexchangeprinciple
Application:
Can be used for laboratory sampling of powders, granules, and drugs.
PTFE material is high-purity, non polluting, and does not contain metal elements; The surface is smooth and flat, without adsorbing the sample. Fully meet the experimental requirements of ultra clean and pollution-free.
PTFE shovel can customize the shape and capacity of the shovel nozzle according to requirements; The diameter and length of the handle.
#Samplinglevel #labware #soursamples #Sampleextraction
Various test tubes, digestion vessels, centrifuge tubes, colorimetric tubes, sample dissolving tanks, microwave digestion vessels, glass vessels, and other holders that can process various aperture and number of positions in digestion vessel.
Both sides can be equipped with handles for more convenient use.
Standard specifications include: 10, 12, 16, 20, 24, 30, 36, 48 positions, etc.
#digestionvessels #vesselholder #laboratoryrack
Used for sample digestion; three bottom options are available: flat bottom, round bottom, and cone bottom; the cover and body are made of high-purity chemical-resistant PFA material.
#PFAVial #samplepreparation #laboratorybottle #digesionvessel
The bottle cap and nozzle are molded in one go with no welding gaps and no liquid leakage;
High purity perfluoroalkoxy resin (PFA) is resistant to strong corrosion;
Fast liquid reflux, smooth material, no residual liquid;
Can be controlled to add liquid in a droplet shape.
#washingbottle #labwarecleaning #chemicalresistance
Batch heating and digestion can be performed on different samples at the same time; the fully enclosed design effectively prevents the entry of acid mist; the surface is covered with Teflon coating to prevent direct metal leakage.
1.Unibody molding, no welding marks, will not break, no Reside.
2.Reservoir and capillary specifications are customizable.
3.Compatible PTFE filter elements sold separately.
Used for trace element analysis, low temperature storage, high performance organic solvent packaging and semiconductor analysis industries.
Pure white appearance100ML; Working temperature -200 250 degrees Celsius PTFE reagent bottles can be customized, trace element analysis, organic solvent storage; Withstand strong acid, strong base, aqua regia and various organic solvents.
Resistant to strong corrosive organic solutions such as aqua regia, hydrofluoric acid, and hydrochloric acid, and can store standard materials for a long time without leaking. 30--5000ml available.
The bottle cap and bottle body are made of high-purity imported PFA and do not contain any impurities. The nozzle and bottle cap are formed at one time, no welding, and not easy to break. Available in 125ml-1000ml.
#washingbottle #teflon #labware #isotope #ICPMS #cleanlab
Widely used in laboratories such as ICP-MS/OES and other trace analysis and isotope analysis.
The outlet of the washing bottle has a fine and even opening, which can be used to configure the standard solution in place of the volumetric flask.
Made of Teflon plastic with screw cap. The cap and nozzle are formed in one piece and are not easy to break. The cleaning solution can be added to the bottle to control the sample addition in drops. The surface is smooth and non-sticky.
#washbottle #teflonlabware #cleaningvessel #traceanalysis
PFA material is resistant to chemical corrosion, has the lowest friction coefficient among plastics, and has good electrical properties. Its electrical insulation is not affected by temperature.Available in sizes from 30ml to 5000ml or even larger. Large size bottle mouth specifications are GL32, GL45, GL60, etc.
#reagentbottle #samplingbottle #labware #teflon #ICPMS
The pore size can be customized according to the needs. The PTFE sieve is a tool for particle size classification and particle size detection. It can also filter and separate the hazards of marine microplastics.
#sieve #Marinegeochemistry
PTFE material is almost not corroded by any chemical substances, including strong acids, strong alkalis, organic solvents, etc., which can effectively prevent chemical corrosion from damaging silicon wafers;
PTFE silicon wafer boxes can maintain stable performance in the temperature range of -200 to+250 ; The surface is smooth and easy to clean, and PTFE has a very smooth surface with low surface tension and friction coefficient, which is not easy to adhere dust and pollutants.
#waferstorage #semiconductor #newenergy
Made of high-purity reinforced PVFE material; resistant to strong acids and alkalis, and most organic solvents. Suitable for all high-purity laboratories with large amounts of acid and high frequency; no deformation or distortion when immersed in boiling water, and can withstand high temperatures and pressures of 120�°C Disinfection; customizable specifications.
#volumetricflaskrack #labware #PVFE
Mobile: +86-153 6614 0844
Wechat/Whatsapp: +86-153 6614 0844
Mail: ClairBZH@gmail.com
PFA ion exchange column, also known as PFA chromatography column, PFA filtration column, etc.
The principle is to use adsorbents to have different adsorption effects on different compounds and different solubility of different compounds in solvents, and to use suitable solvents to allow the mixture to pass through a column filled with adsorbents, so as to achieve the purpose of separation and purification of complex mixtures.
Excellent chemical tolerance, resistant to strong acids and bases; Extremely low dissolution and precipitation, without contaminating the sample.
#Filter #Separation #purification #Perfluoroalkoxyresin
Made of high-purity resin Teflon, it is resistant to strong acids and alkalis, and can withstand high temperatures: -200~+250C. The surface is smooth, non-stick, and easy to clean. Wafer Container specifications and styles can be customized.
A container for carrying semiconductor wafers/silicon wafers, resistant to acid, alkali, and corrosion (strong acid, strong fluoric acid, strong alkali), capable of laser engraving, and able to install RFID. Maintain tracking of carriers and materials.
Mainly used for cleaning, using, and transporting wafers in the acid-base process of semiconductor etching departments.
#wafercleaning #semiconductor #Newenergy #wafers
Digestion instruments with different digits, hole depths, and hole diameters can be customized for digestion tubes of different specifications and materials. A variety of samples can be heated and digested. The surface contains Teflon anti-corrosion coating, the metal elements are not directly exposed, and the experimental results are cleaner.
#samplepreparation #hotblockdigestionsystem #aciddigestioninstrument
Designed specifically for digesting refractory geological samples, the material of the Inner cup can be selected from TFM or PTFE. The maximum pressure can reach 5Mpa. Can be numbered .
1. Designed for the purification of laboratory hydrochloric acid, nitric acid, and hydrofluoric acid to reduce the content of metal impurities in the acid.
2. Generally, for an acid with a metal impurity content of 10 ppb, after one purification, the metal impurity content can be reduced to about 0.01 ppb.
3. Meet the extremely low detection limit requirements of ICP-MS and provide laboratory-grade ultrapure acid for demanding analytical applications.