Hangzhou Easy Electric Supply Cable Limited(EES CABLE)

Supplier From China
Feb-20-17

ACSR conductor consists of a solid or stranded steel core surrounded by strands of aluminium. ACSR conductor is available in a range of steel strengths varying from 6% up to 40%. The higher strength ACSR conductors are used for river crossings, overhead earth wires, and installations involving extra long spans. Against any given resistance of conductor, ACSR conductor may be manufactured to have different tensile strengths as per requirement. The principal advantage of these conductors are their high tensile strength and light weight, covering longer spans with less supports. Due to the greater diameter of an ACSR conductor much higher corona limit can be obtained, giving a big advantage on high and extra high voltage overhead lines.
Standards:
ASTM - B 399 Metric Units
ASTM - B 231
TS IEC 1089
DIN 48201
BS 215
UNE 21.018
Key Benefits:
The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.

ACSR conductors consist of a solid or stranded steel core surrounded by strands of aluminum (E. C. GRADE). ACSR conductors are available in a wide range of steel, containing carbon from 0.5% to 0.85 %. The higher strength ACSR conductors are used for river crossings, overhead ground wires, installations involving extra long spans etc. Against any given resistance of conductor, ACSR may be manufactured within a wide range of tensile strength as per the requirement.

Key Benefits:
The principal advantage of these conductors are high tensile strength so that they are used for longer spans with less supports. Due to the greater diameter of ACSR conductors a much higher corona limit can be obtained causing big advantages on high as well as extra high voltage overhead lines.


Specifications
Aac condcutor
Concentric al stranded condcutor
Standards: iec, astm, bs, nfc, csa, etc.
Code: iris, aster etc.
Overhead line conductor aac

1. Application:
Bare conductor made of aluminium wire stranded and corrugate aluminium pipe, maily used as busbar of subsationsin high altitude, widely used in power plant, and substation, especially used as busbar of substation over 2000 meter of altitudes

2. Series:
Bare conductor are covering series of conductor, aac, aaac, acsr, acar etc.

Corrugated aluminium pipe busbar, made of aluminium wires or aluminium alloy wires stranded around aluminium pipe.

3. Specification: can be produced up to 600-1600 sqmm (equal to aluminium's section-area)

4. Standards: the products can be made complying with the standards: iec, bs, din, astm, csa, etc


Brief Introduction
PVC/XLPE power cable is used to transmit and distribute power in power transmission and distribution system of 35kV or lower. It is generally applied to the fields including power, construction, mines, metallurgy, petrochemical industry and communication in complete replace of oil immersed paper insulated power cable and in partial replace of PVC insulated power cable.
Standard
The products can be produced according to our factory specification which is equivalent to the standard IEC60502. The factory can also design and manufacture special power cable according to the other standards required by the customers.

Properties of PVC Power Cable

1. The long-time permissible working temperature of cable conductive core is not more than 70 degrees.
2. During short circuit (max permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165° C.
3. The difference level of laying cable is not restricted. When laying the cable, ambient temperature is not lower than 0° C.
4. They have good chemical stability, and properties of acid resistance, alkali resistance, salt resistance, oil resistance, solvent resistance and flame resistance.
Properties of XLPE Power Cable
1. The highest allowed operating temperature of conductor for long-term working is 90 degrees.
2. In short circuit (Max long term is no more than 5 seconds). The highest temperature for conductor is no more than 250 degrees.
3. The cable is laid without horizontal drop limit. The environment temperature should be no lower than 0 when lay. Otherwise it should be preheated.
4. Excellent electrical performance, resistance to chemical corrosion.
5. Can stand advisable traction when laid. Can stand traction from Outside. Left low smoke halogen-free after burned. Retard the burning of the cable.
Nominal Cross-sectional Areas
1.5 mm2, 2.5 mm2, 4 mm2, 6 mm2, 10 mm2, 16 mm2, 25 mm2, 35 mm2, 50 mm2, 70 mm2,
95 mm2, 120 mm2, 150 mm2, 185 mm2, 240 mm2, 300 mm2 400 mm2, 500 mm2, 630 mm2,
800 mm2
Production range
Single core cable: From 1.5 mm2 to 800 mm2,
Multi-core cable: From 1.5 mm2 to 400 mm2


Specifications
-Variety size, national standard
-Rated voltage: 450/750V
-Prompt delivery, quality assured
-Manufacture more than 20 years
1. Electrical wire are used indoors, aluminum conductor and PVC insulation
2. We can also supply the copper conductor and PVC insulation electrical wire
3. Range of application: This product is fit A. C rated voltage450/750V
4. If you have any problem about the electrical cable and wire, please feel free to connected with me.


Specifications
1. Overhead insulated electrical cable astm/bs/din iec standard
2. Best price quality and package fast delivery
Al/xlpe overhead abc cable (aerial boundled cable) single/duplex/triplex/quadruplex/five stranding.
1. Application of service drop cable:
Service drop cable(abc cable) are mainly used for electric power transmission, rebuilding of urban and forest regions. They can improves safety and reliance of electrified wire netting.
2. Types of service drop cable:
Service drop cable(abc cable) covers mainly three types:
Duplex service drop triplex service drop quadruplex service drop
2.1 duplex service drop
Applications
To supply 120 volt aerial service for temporary service at construction sites, outdoor or street lighting. For service at 600 volts or lower at a conductor temperature of 75 maximum.
2.2 triplex service drop
Applications
To supply power from the ulility`s lines to the consumer`s weatherhead. For service at 600 volts or less(phase to phase ) at a conductor temperature of 75 maximum for pe insulation or 90 maximum for xlpe insulation.
2.3 quadruplex service drop
Applications
To supply 3 phase power, from a pole-mounted transformer to the use`s servic head where connection to the service entance cable is made. To be used at voltages of 600 volts or less phase to phase and at conductor temperature not to exceed 75 for pe insulated conductors or 90 for xlpe insulated conductors.
Conductor standards:
1. B-230 aluminum wire, 1350-h19 for electrical purposes.
2. B-231 aluminum conductors, concentric-lay-stranded.
3. B-232 aluminum conductors, concentric-lay-stranded, coated steel reinforced (acsr).
4. B-399 concentric-lay_stranded 6201-t81 aluminum alloy conductors.
5. B498 zinc-coated steel core wire for aluminum conductors, steel reinforced (acsr).
6. Duplex service drop cable meets or exceeds all applicable requirements of ansi/icea s-76-474


 
 