Product Description
Standard
The product is manufactured according to the standard of GB14049”Aerial insulated cables of rated voltages 10KV and 35KV” and IEC60502”Extruded solid dielectric power cables for rated voltage form 1KV to 30KV”.
Operating characteristic
Rated voltage: 10KV 35KV
Max.permissible continuous temperature:
HDPE insulated aerial cables :75du.
XLPE insulated aerial cables: 90du.
Max.short-circuit temperature of the conductor should not exceed:
HDPE insulated aerial cables :150du.
XLPE insulated aerial cables: 250du.
The installation ambient temperature should no below: -20du.
The bending radius of cables are recommend as follows:
Single cable:not less than 20 times the diameter of cables;
Multi-core cable:not less than 15 times the diameter of cables.
Packaging & Shipping
In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.
Product Description
Standard
The product is manufactured according to the standard of GB9930 ”Polyvingyl chloride insulated control cable”, IEC60502 “Extruded solid dielectric insulated power cables for rated voltages from 1 kV up to 30kV”.
Applications
PVC insulated and sheathed control cable is suitable to the interconnection in controlling, signalling, protecting and measuring systems with rated voltages up to and including 450/750V or 0.6/1kV.
Operating characteristics
1. Rated power-frequency voltage Uo/U: 450/750V or 0.6/1kV.
2. Max. Permissible temperature operating temperature of conductor: 70?
3. The ambient temperature under installation should not below 0?, if the ambient temperature is lower than 0?, the cable should be preheated.
4. The bending radius of cable are recommended as follows:
Non-armoured cable: not less than 6 times of the cable diameter.
Armoured or copper tape screened cable: not less than 12 times of the cable diameter.
Screened fiexible cable less than 6 times of the cable diameter.
Packaging & Shipping
In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.
Product Description
Reference standards
The product is manufactured according to the standards of CB5023 and Jb8734 or IEC ,BS ,DIN and ICEA upon request.
Application
The products are suitable for power installation fixed wiring or flexible connection for el-electrical appliances with rated voltage up to and including 450/750V respectively.
Operating Characteristics
Rated voltage Uo/U:450/750V\300/500Vand300/300V
Max. Permissible continuous operating temperature of the conductor:
227 IEC 07(BV-90)..........................90?
227 IEC 08(RV-90)............................90?
For other type.................................70?
The ambient temperature under installation shall not bellow 10?
The bending radius of cable :
D=25mm..................................=4D
D>25mm..................................?6D
(D-Diameter of the cable)
Packaging & Shipping
In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.
Product Description
Standard
The product is manufactured according to the standard of GB12706 and GB12666 or IEC,BS,DIN,ICEA, and JIS upon request.
Application
The product is suitable for use in power distribution lines or fixed installations with rated power-frequency voltage up to and including 0.6/1kV
Operating characteristics
Rated power-frequency voltage Uo/U: 0.6/1kV
Max. Permissible continuous operating temperature of conductor(PVC/XLPE):70?/90?
Max. Short-circuit temperature of conductor shall not exceed(5s maximumduration):
PVC: cross-section of conductor=300mm2-160?
cross-section of conductor=300mm2-160?
XLEP:250?
The ambient temperature under installation should not below 0?
The bending radius of a single-core cable should not less than 20 times of the cable diameter.
The bending radius of multi-core cable should not less than 15 times of the cable diameter.
Packaging & Shipping
In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.
Product Description
Reference standards
The product is manufactured according to the standards ‘Rubber insulated cables of rated voltage up to and including 450/700V’ of JB8735, and QB ,and the same time is also manufactured according to the standard of IEC,England,Germany and America.
Application
Rubber insulated wires and cables are suitable for power device with moving installation and rated voltage up to and including 450/750V.
Operating Characteristics
Rated voltage Uo/U:450/750V\300/500Vand300/300V
Permissible continuous operating temperature of the conductor:
Max...60?
Lowest...-35?
YQW,YZW,245IEC57,YCW,245IEC66,245IEC82,YHF cables can be used at places contaminated by mineral oil and fuel oil.
The bending radius of cable :
D=25mm..................................=4D
D>25mm..................................?6D
(D-Diameter of the cable)
Packaging & Shipping
In coils, wooden drums, steel drums or steel-wooden drums.
We could producing according to the customers' requirements.