Technical Parameters
Method of Display 7 inch color touch LCD with English display
Method of Testing MPU controlled electrolysis(Karl Fischer Coulometric Method)
Rate of Electrolysis 2.4mgH2O/min
Electrolysis Current Auto-control within 430Ma
Testing Range 0.01ugH2O-200mgH2O
Water Content Range 0.0001%(1ppm)—100%
Sensitivity 0.01ugH2O
Accuracy Water Content: 2ugH2O-100ugH2O; Deviations=±1ug,
Water Content: 100ugH2O-1000ugH2O; Deviations=±2.9ug,
Water Content: >1000ugH2O; Deviations=±0.2%(excluding deviations of sample injection)
Drift Compensation Auto-control via MPU
Stirring Speed Adjustable and steerable
End-point Indication LCD display /output via printing / voice warning / end-point indication light
Data Input Input via touch screen
Sample Number Numbered by users
Storage Infinite storage capacity
Printer Thermal printer, high-speed, low-consumption, with 44 millimeter-wide paper
Printing Content ug / ppm / mg/L / sample number /experimenter / date
Calendar/Clock automatic display and print analyzing time and date
Self-checking Breakdown self-checking
Special Function Work independently or connected with laptop or other computers
Power Consumption <40W
Dimension 390×270×190mm
Working Environment Temperature: 5?-40?,Humidity: <85%
Power Supply AC220V±10% 50HZ±2.5HZ
Weight About 7kg
Application:
This TP-2100 water content tester adopts the global recognized classical moisture testing method - Karl Fischer Coulometric Method which is the most accurate method with low cost. With the universal standard and analyzing method, it can quickly analyze the moisture content in liquid, solid and gas and directly display testing results, with testing range from 0.0001%(1ppm) to 100%. Therefore, this testing method has been widely used in institutions and enterprises of petroleum, chemical industry, power, pharmaceuticals, pesticide, railways, research, etc.
Features:
1. Powerful Itanium and double CPU; direct A/D conversion of testing electrode data.
2. 7 inch color touch LCD display in English. Function of reagent failure prompt, extending the service time of it.
3. Completely closed titration system avoids direct touch between people and the reagent as well as the influence of environmental humidity.
4. The outer shell is made of high-quality cold-rolled steel plate with electrostatic sprayed surface, anti-corrosion and easy to clean.
5. Auto-control and compensation of electrical current via MCU contributes to quick balance of reagent.
6. Auto-control electrolysis current within 430mA ensures high sensitivity and fast analyzing speed.
7. Preinstalled with cubature (including 3 pieces of formula), statistical calculation (including average calculation, standard deviation calculation and rate of change calculation) and elementary arithmetic, with the advantages of auto-analysis and calculation.
Place of Origin: Chongqing, China (Mainland)
Brand Name: TOP
Model Number: ACD-3000I
Power: Electronic
Usage: Auto Testing Machine
Type: Fully Automatic Oil Acidity Tester
Condition: New
Method of Display: 7 inch color LCD
Testing Range: 0.0005~0.5000mgKOH/g
Power supply: 220V±10%,50Hz±5%
Environmental Humidity:
Application:
Purify various of unqualified or used insulation oils including aging transformer oil, mutual inductor oil, switch oil. Vacuum dehydration and degasification as well as filtering. Also it can inject the insulating oil into transformers.
Features:
1. Small size. Low cost. Most populler Can live operated with electricity, vacuum oil and dry power equipment.
2. Bi-infrared liquid Duplex 3D stereo-evaporation technology to dehydrate and degas oil effectively.
3. Oil of any grades can be treated on line at working site
4. Can not only work independently but also with oil regeneration system.
Application:
Purify and regenerate used insulating oils includes transformer oil, switch oil, circuit breaker oil, capacitor oil, mutual inductor oil in power generation plants, transformer stations, electric transmission and supplying company, factories, mines, railway transportation, etc. It can be used as special equipment for electric power transformer maintenance.
Features:
1. Besides dewatering, degassing and filtering, it regenerates oil by removing polarity materials such as the deep oxides, free carbon etc effectively.
2. Three ways of using: vacuum system and filtering system can work independently; so does the regeneration oil system; also they can work at the same time.
3. Special absorbing agent to remove free carbon and water-soluble acid so as to improve flash point, acid value and dielectric property of oil.
4. Chain safety protection system, pressure protection device, interaction of oil inlet and heating, infrared oil level control system to help avoid damage from incorrect operation.
5. Convenient for vacuum pumping and oil filling to transformers.
Description:
Condition: New
Structure: Vacuum
Place of Origin: Chongqing, China (Mainland)
Brand Name: TOP
Model Number: ZYD
Weight: 600-2200kg
Certification: CE; ISO
Warranty: 2 years
After-sales Service Provided: Engineers available to service machinery overseas
Type: Double-Stage Vacuum Transformer Oil Purifier
Color: As required
Function: Dehydration, degasification
Working vacuum: -0.08 -0.099MPa
Working pressure:/=75kV
Moisture content:
Description:
Condition: New
Structure: Vacuum
Place of Origin: Chongqing, China (Mainland)
Brand Name: TOP
Model Number: ZYD
Weight: 600-2200kg
Certification: CE; ISO
Warranty: 2 years
After-sales Service Provided: Engineers available to service machinery overseas
Type: Double-Stage Vacuum Transformer Oil Purifier
Color: As required
Function: Dehydration, degasification
Working vacuum: -0.08 -0.099MPa
Working pressure:/=75kV
Moisture content:
Place of Origin: Chongqing, China (Mainland) Brand Name: TOP Model Number: ACD-3000I Power: Electronic Usage: Auto Testing Machine
Type: Fully Automatic Oil Acidity Tester
Condition: New
Method of Display: 7 inch color LCD
Testing Range: 0.0005~0.5000mgKOH/g
Power supply: 220V±10%,50Hz±5%
Environmental Humidity:
Description:
Condition: New
Structure: Vacuum
Place of Origin: Chongqing, China (Mainland)
Brand Name: TOP
Model Number: ZYD
Weight: 600-2200kg
Certification: CE; ISO
Warranty: 2 years
After-sales Service Provided: Engineers available to service machinery overseas
Type: Double-Stage Vacuum Transformer Oil Purifier
Color: As required
Function: Dehydration, degasification
Working vacuum: -0.08 -0.099MPa
Working pressure:/=75kV
Moisture content:
Place of Origin: Chongqing, China (Mainland)
Brand Name: TOP
Model Number: IT-800
Power: Electronic
Usage: Auto Testing Machine
Method of Display: large LCD display screen, in English
Method of Testing: Platinum ring method
Testing Range: 0-200mN/m.
Accuracy: ±0.1mN/m
Application:
IT-800 analyzer, adopting ASTM D971 “platinum ring method”, tests interfacial tension for various liquids (between liquid and air) and also that between mineral oil and water(between liquid and liquid) by means of automatic control of internal microcomputer under circumstances of nonequilibrium. It only needs you pour the sample into sample cup and then press “start” button. Then the tester will finish the whole test and calculate the tension value automatically according to concrete input parameters.
Features:
1.Large color LCD screen, English prompt, menu operation, fully automatic testing.
2.Automatic temperature compensation within 25? eliminates the influence that the temperature imposes on the tension value.
3.Functions of auto correction, auto testing, calculation, results displaying, and storage under power off circumstance.
4.The main body is equipped with hurricane globe, which lessens the influence outer matters impose on testing results.
5.Automatic lift of the lift platform ensures a stable environment and high accuracy.
6.It adopts enclosed magnetic pot type sensor and multi-point calibration of uniform space technology, which improves the repeatability and reproducibility of the results.
7.It can work independently and can also realize network management via connection with laptops or microcomputers through USB interface.
8.Tester program can be updated accordingly if related national standard revised.
Application:
Specially designed for on site use to completely regenerate insulating oils in energized or de-energized transformers. Provide regular oil purification including degassing, drying and particulate removal but also remove acidity, sludge, other soluble oil decay products, and improve color. For special application, the system also can be mounted on a leak proof base or be installed and operated on a trailer.
Condition: New
Flow: 30~300L/min
Working Pressure: