Product Description
portable body, weighing only 7kg, easy to carry & maintain, maximum output pressure up to 15000psi. The fault can be self-maintenance during site operation. The medicament can also be injected into small cracks and pores.
Constuction location
Leak-stoppage, waterproof & reinforcement for concrete structure, such as basement, floor, the second joints, subway, tunnel, Continuous wall, cracks, water seepage, etc.
Material application
Pu foam stop leakage agent, Epoxy resin, nongranular mobile-liquid
specification
SL-999
Net weihgt7kg
Maximum output pressure15000psi
Pressure of starting againless than 8000psi
Safe range of high-pressure hoseless than 15000
Safe range of switch valveless than 15000psi
Packing size32*20*49CM
Power600w/220v
the length of hose5m
Weight: 7kg
Power: 600w/220v
Packing:32*20*49
Max output pressure: 15000psi
Shenglong Injection packer for high pressure grout
Features
High pressure injection packers for concrete crack repairs , waterproofing ,rehabilitation of concrete structures , basement leak sealing cracksealing etc.
Shenglong injection packer for injection machine spare parts is uesd with the Shenglong injection machine in concrete crack repair and water leaking stop. It suits for both polyurethane and epoxy injection.
Method of Construction for Injection
1.Crack and leakage condition inspection
Check the process procedure after finding the thickness, width and depth of crack and leakage condition of the structure
2.Drilling Operation
Drill directly into crack section if the thickness of concrete is thinner than 10cm. For the thickness of 10~50cm, drill it with 45 degree angle by keeping a distance of 1/5 of concrete thickness. Make sure it penetrates the crack section. If the thickness is over than 50cm, keep the distance of 20~30cm and drill it with 45 degree angle until it penetrates crack section. And keep drilling by maintaining the fixed interval. (5 holes per 1 meter. Drill it in zigzags)
3.Packer Installation
Clean the inside of drilled holes with compressor. Make sure that rubber sleeve of packer and cutting line of tightening nut should be put into the inside of concrete surface when installing. Tighten the packer completely by using the T-box. (Packer might be damaged if you tighten it too strongly)
4.Injection Operation
Inject the waterstopping material by using the high pressure device or grease gun. Maintain the initial injection pressure as around 40kg/cm and increase the pressure by each 10kg/cm gradually until the waterstopping material flows out from crack section. Water will come out from the crack section first and then waterstopping foaming agent and then water stopping liquid at last. If the waterstopping material that is not foamed comes from the crack section, then move to next packer for injection.
5.Packer Removing Operation
Remove and break the packer by using vise pliers or hammer as a tool. If there is still a wet section, then inject the water stopping material again.
6.Finishing Operation
Remove the water stopping material that is remained on the crack section. Spreading with the elastic sealing material.
SL-8 (80*13.5*14)mm
SL-10 (100*13.5*14)mm
SL-15 (150*13.5*14)mm
SL-20 (200*13.5*14)mm
SL-25 (250*13.5*14)mm
SL-30 (300*13.5*14)mm
SL-100 (1000*13.5*14)mm
In carton