ARIES 2500 Anesthesia Machine:
Display: 10.4 TFT color screen
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi~open, Semi~closed or closed system
Anesthetic vaporizer: two high precise vaporizers
Power supply: 220V,10%, 50Hz,1Hz
10V,10%, 60Hz,1Hz
Internal battery: DC12V (4 working hours)
Fresh gas outlet is in front of frame
Anesthesia Ventilator:
Respiration mode: IPPV, VCV, PCV, SIMV, SIGH, MANUAL, STANDBY, DEMO
Waveform: P-t, F-t, V-t, F-v, V-p
Tidal Volume: 20~1600ml
Respiratory frequency: 1~65bpm
I:E ratio: 4:1~1:4
Inspiration pause: 0~55%Ti Inspiration Pressure: 1~60cmH2O Trigger Pressure: -20~20cmH2O
Monitoring parameters: O2 concentration, MV, Respiratory frequency, Tidal volume, Ppeak, PEEP, I:E ratio, Pmean, Compliance etc..
Alarm parameters:
high pressure alarm, low pressure alarm, O2 concentration alarm, MV alarm, O2 source failure alarm, AC power failure alarm, etc.
Pressure alarm setting:
High pressure alarm set 1~60cmH2O.
Low pressure alarm set 0~20cmH2O
O2 concentration alarm setting:
high: 21~99%.
Low: 21~50%.
MV alarm setting:
MV high alarm set 10~99L/min
MV low alarm set 0~40L/min
Main Unit:
Circle absorber: Compact circle absorber
Flow meter:
Five~tube flow meter O2 tube: 0L/min~1L/min~10L/min.
N2O tube: 0L/min~1L/min~10L/min.
Air tube: 0L/min~10L/min
O2 and N2O Linkage Device, keep oxygen concentration not lower than 25%
Oxygen flush: 25L/min~75L/min
Gas source pressure:
O2: 0.25Mpa~0.65MPa
N2O: 0.25Mpa~0.65MPa
Air: 0.25Mpa~0.65MPa
Gauge: 4 units, 2¡ÁO2£¬N2O, Air.
Special Feature:
Ventilation method: Closed, half-closed, half-open
Small and compact unit ideal for office based anesthesia
Two-gas machine( N2O&O2 )
Mechanical Anti-Hypoxic Device and O2/N2O interlock
External CO2 circle absorber system
Vetilator (option): TH-1, TH-1 A
Main Unit:
Tidal volume( Manual Mode): 20 ~ 1500ml
Gas pressure: 0.25 ~ 0.65Mpa
Flowmeter:
O2 :0.1 ~ 10L/min
N2O:0.1 ~ 10L/min
APL valve: 0.5 ~ 6.0Kpa
O2 Flush: 25 ~ 75L/min
Ventilator TH-1
Special Feature:
Driven mode: Pneumatically driven electronically controlled
Display: High light LED display
Ventilation mode: IPPV and Manual mode
Tidal volume: 50 ~ 1500ml
Breath frequency: 1~ 90Bpm
I:E ratio: 4:1 ~ 1:6
Monitor parameter: Tidal volume, breath frequency, MV, airway pressure
Alarm: MV high alarm£¬MV low alarm, TV high alarm, TV low alarm
Ventilator TH-1(A):
Special Feature:
Respiration mode: IPPV, SIMV, MAUAL
Display: 5.5¡¯ SNT screen
Waveform: P-t, V-t
Tidal volume: 50 ~ 1600ml
Breath frequency: 1~ 65Bpm
I:E ratio: 8:1 ~ 1:8
Alarm parameters: High pressure alarm, Low pressure alarm
High pressure alarm limit: 20 ~ 60cmH2O
Low pressure alarm limit: 0 ~ 20cmH2O
Monitor parameter: Tidal volume, MV, Ppeak, PEEP, respiratory frequency, I:E ratio
Safety valve pressure limit: 6Kpa
Good air tightness, high reliability, and minor respiration impedance.
Special Feature:
Application: Adult, Pediatric
Driven mode: Pneumatically driven electronically controlled
Mode: Semi-open, Semi-closed or closed system
Anesthetic vaporizer: One vaporizer
Anesthesia Ventilator:
Display: High light LED display
Ventilation mode: IPPV and Manual mode
Tidal Volume: 50 ~ 1600ml
Breath frequency: 1 ~ 90BPM
I:E ratio: 4:1 ~ 1:6
Monitor parameter: Tidal volume, breath frequency, MV, Airway pressure
Alarm: MV high alarm, MV low alarm, TV high alarm, TV low alarm
Main Unit:
Circle absorber: Compact circle absorber
Bellow: 50 ~ 1600ml
Oxygen FLUSH: 25L/min ~ 75L/min
Flow meter:
O2, N2O two-tube flowmeter
O2 tube: 0L/min ~ 10L/min
N2O tube: 0L/min ~ 10L/min
O2 and N2O linkage device
Adjust O2 and N2O in proportion ( keep O2 concentration not lower than 25% )
Gas source pressure:
O2: 0.25 ~ 0.65Mpa
N2O: 0.25~ 0.65Mpa
Gauge: 2 units, one N2O, one O2.