PN: HSD7100X0400 Brand: HONSSEMI Specification: IFAVM=7100A @ Half sine wave, Tc = 85 ¡ãC VRRM=400V @ Half sine wave, tP = 10 ms, f = 50 Hz VRSM:450V VF0=0.74 V @Tj = 170 ¡ãC rF = 0.026 IFRMS =11200 A @ Half sine wave, Tc = 85 ¡ãC IFSM=55000 A IRRM£º 50 mA @ Tj = 170 ¡ãC VR = VRRM. Electrical Characteristic: Optimized for high current rectifiers Very low on-state voltage Very low thermal resistance. Application: Welding Machines.
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Flexible fireproof cables are composed of copper stranded wires, mineral compound insulation, and mineral compound sheaths. This kind of cable has non-combustible, smoke-free, non-toxic and fire-resistant characteristics. The structure of the flexible mineral insulated cable adopts a flexible structure and materials that are made of mineral compounds, which make up for the defects of hard structure, flammability, and toxicity. It also has some advantages that other cables cannot have, such as: fire resistance, large current carrying capacity, Impact voltage resistance, mechanical damage resistance, halogen-free, non-toxic, explosion-proof, waterproof, corrosion resistance, long life, safety, overload resistance, high temperature resistance, low cost, etc. Flexible fireproof cables have an important role in protecting lives, materials, and information security. They are used in trunk lines, fire lines, escape rescue systems, such as emergency lighting, fire monitoring, alarm systems, elevator systems, smoke exhaust systems, and control lines, etc. Flexible fireproof fireproof cables used in trunk lines, fire lines, escape and rescue systems, such as emergency lighting, fire monitoring, alarm system, elevator system, smoke exhaust system, and control lines, etc. Flexible fireproof fireproof cables used in Public buildings: high-rise buildings, underground buildings, hotels and restaurants, hospitals, schools, business centers, government affairs centers, department stores, large supermarkets, logistics warehouses, financial institutions such as banks, securities and insurance, post and telecommunications centers, power control rooms, substation rooms, museums, memorials and other historic buildings. Flexible fireproof fireproof cables used in Infrastructure: airport terminals, stations, hub centers, ports, subway systems, Bridges, tunnels. Flexible fireproof fireproof cables used in Industry: coal mining, coal chemical industry, oil field mining, petrochemical industry, oil refinery, metallurgical industry, iron and steel industry, shipbuilding industry, aerospace, electric power industry, pharmaceutical industry, glass industry, paper industry, military system. Flexible fireproof fireproof cables used in Fire prevention, explosion prevention, high temperature places: oil depot and gas station, natural gas transmission and compression station, garden landscape, historic sites, wood structure buildings
Photocells Fans & ventilation, Hazardous area lighting Industrial plugs & sockets Industrial & commercial Lamps Light fittings: fluorescent, weatherproof & floodlighting Refrigeration & air conditioning spares Water heating elements Wiring accessories MCB's Circuit breaker Vacuum Breakers Control transformers Fuses & load break devices Hazardous area products Industrial beacons Industrial sounders, buzzers Industrial surge protection Safety switches Clamp meters Multi-meters Testers Semiconductors: thyristors, rectifiers Pressure switches Solenoid & pilot valves Photoelectric Sensors
Supplier: Flanges: slip on, welding neck/long welding neck, socket welding, threaded, blind/bossed blind, orifice, special flanges as per customer drawing, fasteners (socket head, set screw, counter sunk, button head, hexagonal head bolts & screws, hex nuts) washers, dowel pins (parallel pins, taper, knurled pin, spiral pin, grooved, clevis), guided bushing, friction grip bolt, cold forged components, gear shaft, spline shaft, kick shaft, ball pins, ball rods, shaft for alternator or stators, brake scam, piston pin, material grades like alloy steel 8.8, 10.9, 12.9, 45h, 14.9, 14k, stainless steel a1, a2, a3 & a4, 204, 410, 416, 431, 420, brass, aluminum v65/2024, titanium bt16, gears, timing belts, bearings, gaskets, o rings, seals, keys, grinding wheels and abrasive paper, welding rods, hexagonal wrench, a4 papers reams, tapes, corrugated sheets, boxes, cnc, vmc machine precision component(turning, milling, moulding & fixtures tools).
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF101A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF101A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 0.5 - 5 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF102A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF102A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 1 - 10 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ 013 Wiring Diagram MPDZ609-01-1
ALSTOM Reverse Power Relay CCUM 21 High Res GBCCUM21PF103A DEFINITE TIME REVERSE POWER RELAY Technical Specifications Model No : CCUM21PF103A CCUM21 AUX. CURRENT OR VOLTAGE - 24V DC C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1-1/2D VERT. 10T CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH MTA PHASE-CHAR ANGLE - 30 DEGREES TIME DELAY P/U OR D/O - 2.5 - 25 SECS. V.T/P.T SECONDARY - 110V AC External Resistor Name Plate RFH9072-604 RZF9151-601 Outline Diagram MFJ013 Wiring Diagram MPDZ609-01-1