Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
Supplier: Tarpaulin, tarp, pe tarp, frp, grp, grating, pultruded, composite, frp rebar, panel tanks, pond liner, geomembrane, junction box, truck cover, boat cover, tent, camping, current transformers, indoor current transformers, outdoor transformers, switch gears, oil filled tank type transformers, wound primary type transformers, bar type transformers, window type transformers
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. BRAND: SCHNEIDER ELECTRIC AND ALL OTHER BRAND AVAILABLE. we are trader of Distribution Transformer and supply all over world. We have 20 Years Experiance Technical team for Desining and Winding of Diffrent types of Transformer. We have 15 Years Experiance Technical Team for Testing of Transformers. We can supply transformer up to 33kV and up to 5000kVA.
Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA,1s Rated insulation level 12/42/75 kV Ambient temperature 25~40 Altitude Up to 1000m above sea level Indoor device Standards The product performance is in accordance with GB20840.1 GB20840.2 and IEC61869-1 IEC61869-2 standards.
TRANSFORMER : ALL TYPE : Dry Type/Air Cooled, Oil Cooled, Water. We can supply small transformer from 33kV and up to 54000kVA or more. For more details please contact us.
Transformers
JDZX10-12 voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 12 kV. Usage Terms J: Voltage transformer D: Single-phase Z: Casting insulation X: Residual voltage winding 10: Design No. 12: Rated voltage Main technical parameter 1. Rated primary voltage:11/kV or 10/kV etc. 2. Rated secondary voltage:100/V?110/V ? 115/V? 120/V 3. Rated voltage of residual voltage windings:100/ 3V ?110/ 3V? 115/ 3V? 120/ 3V 4. Burden power factor: cosF=0.8(lagging) 5. Standards: IEC60044-2.2003 Instrument transformers-Part2: Inductive Voltage transformers Other technical parameters pls see as follow: x1204.png Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Supplier: Japanese quality switchgear components, breakers, magnetic contactors, switches, pilot lights, pushbuttons, panel instrumentations, power management meter, protection relays, transformers, inverters, ups.
Transformer up to 33 kv & 10 mva ratings Depending on customers requirement
We are recognized as the foremost trader and supplier of high quality range of distribution transformers. The offered transformers fabricated using the best grade raw material and latest technology in accordance with the set industry standards at vendors’ end. Owing to their salient features such as corrosion resistance, longer service life, supreme performance and dimensional accuracy, these transformers have gained huge demand in the market. Extremely durable, these are rigorously tested on various parameters of quality by our vendors. Specifications: Distribution transformers from 5 kva to 2500 kva up to 33kv class As per mutual discussion