Features Current Meter Digital True RMS Current Meter Installed in Rack Horizontal Power Monitor Meter, Web, SNMP, Free Bundle Software Power Control Web, SNMP Audible Alarm 2 Phase, Warning and Overload Event Alert Email, Trap, Audible Alarm Protection Circuit Breaker Includes Mounting Bracket; User manual; Amazing PDU Software. -------------------------------------------------------------------------------- Specification General Output (8) IEC320 C13 Input (1) IEC320 C20 attached power cord, 3 meters long Protection (1) 16 AMP Circuit Breaker Communication IP Address (1) Yellow LED PDU Status (1) Green LED Power Status (8) Green LED Power Monitor (1) RJ45 for Ethernet Current 3 Digits Meter Range: 0A ~ 20 A Resolution: 0.1A Precision: +/-2%+/-0.1AMP Size 90 x 432 x 44 mm Weight 3 kg 1pc/ box, 6 boxes/ carton.
Supplier: Power distribution unit, KVM solution, signage solution
Supplier: UPS, DC to AC inverter, automatic voltage regulators , power distribution units (PDU)
Ericsson BTS / PDU - Power Distribution Unit PDU0201
Supplier: Electrical switchboard below 40.5kv, sf6 insulated switchgear, rmu, compact substation, power distribution units, vcb, mccb etc.
Services: Electrical facility installation, testing, repairing and maintenance.
Supplier: High quality, refurbished I.T. assets, specializing in server components and related I.T. equipment, includes power distribution units (pdus), power supply units (psus), cabling solutions
Services: Sourcing, logistics and reverse logistics
Product Details : The Transformer used in the power supply unit is manufactured as per the UL norms. The transformer will be potted/sealed in an enclosure using Epoxy (a mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer's needs a circuit breaker of 25A is provided for circuit protection. Technical Details : Wattage - 75w to 1200w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages as per customer requirements Insulation class F, H Max. regulation 10% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.
To meet the requirement of the network system to the power, santakups has developed a new generation ups - bpro offline series. It adopts 32bits data-bus microprocessor with robust processing power that is capable of detecting and controlling quickly and accurately all movement of ups to ensure product high reliability. Owe to the use of the double-conversion circuit design, the power used by load is the pure sine wave power by stabilizing voltage and stabilizing frequency and noisy signals filter. Specificationú¦ model b500a/600a b1000a/1200a Max capacity(va) 500va(300w) 1000va(600w) Rated capacity 600va(360w) 1200va(720w) Input commerical power range 145vac-280vac Avr range 165vac-270vac Frequency 50hzía10% Output commerical power sine-wave Inversion simulated sine-wave Frequency commercial power supply:shared frequency with the commercial inversion state:50hzía0.5 Avr voltage range 220vacía10%(auto-sensing) Transfer time typical:5ms(including detection time) Protection overload ups automatically shutdown if overload exceeds 150% of normal value for 30 seconds and 180% for 3 seconds Tel/fax/modem no Short circuit ups output is cut off immediately or input circuit breaker protection Alarm battery back-up beeping sound every 4 seconds when the input is cut off Battery low voltage beeping sound every 1 seconds when the input is cut off Overload continuously beeping sound when overload Battery type sealed, maintenance-free lead acid Capacity (12v, 7ah)x1 (12v, 7ah)x2 Recharge time 8 hours to 90% of full capacity Back-up time typical 20 min(halfload) Battery protection automatic self-test, discharge protection
Supplier: Air conditioning, uninterruptible power supplies (UPS), power distribution units (PDU), generators, access flooring, fire suppression, transformers
Buyer: Air conditioning, uninterruptible power supplies (UPS), power distribution units (PDU), generators, access flooring, fire suppression, transformers