The Automatic Civil Static Discharger BaiXin Automatic Civil Static Discharger ó=,it can eliminate the daily static full-automatically. Wear it on the wrist, just like wearing the wrist-watch. It can survey and dispel the static automatically, that on user's body and on the object in range of 30cm. So, while wearing it, it will dispel the static that the human body produced at any time. Keep the static in the human body within a level harmless to health.And before you touch objects, dispel the static on those objects in order to prevent you from being hit to by the static.(Its speed of dispelling the static is enough to dispel the static of both sides before your hands meet the other side.) It has many kinds of ways of wearing, you can choose according to the need. Using it, you can totally get rid of the interference of the static. Function Wide range: FA service range covers an area within a 30cm radius from this product which can be used for human body, vehicle, electronic product, hardware, etc. (The actual service range depends on the environment of use) Fast: Static electricity can be eliminated within 0.2 second. Good effect: completely clear up the static hazard. Safety: This product is absolutely safe without any poison and hazard. Usage Just wearing the discharger, it will automatically eliminate static. There are many wearing ways: ó+ Wear on the wrist (recommended wearing way); ó+ Hang on body; ó¦ Put into pockets; When meeting static, the static indicator light will show, then static hazard has been eliminated. The Detail Specificationú¦ Product specificationú¦4.5cm*3cm*1.5cm Model numberú¦BX--42 Color ú¦(shell+face) silver+blickíówhite+redíówhite+whiteíówhite+orangeíópink+pink Customized Productú¦ Negotiation OEM: 10,000 more Silkscreen: Yes (above 1000) Quality / Safety Certification: CE ROHS Pack the way ú¦B=B Corrugated Carton PS: The static hazard Ø Static may cause all kinds of cardiovascular disease (arrhythmia, tachycardia,etc.); Ø Static may cause myocardial infarction or cerebral thrombosis for the elderly; Ø Static may cause pregnant women in progesterone levels dropped to abortion or premature, or even to fetal deformity; Ø Static may inhibit male hormones of the elderly, and cause the sex dysfunction; Ø Static may cause premature senility; Ø Static may cause headache, insomnia, palpitation, nausea heart, psychological Ø Static may cause skin dryness, allergies, itch,erythema and pigmentation. Ø Static can cause electronic products injury, shorten usage life and cause fires etc. Product specificationú¦4.5cm*3cm*1.5cm Pack the way ú¦B=B Corrugated Carton
The Automatic Civil Static Dischargeró= BaiXin Automatic Civil Static Discharger ó=,it can eliminate the daily static full-automatically. Wear it on the wrist, just like wearing the wrist-watch. It can survey and dispel the static automatically, that on user's body and on the object in range of 30cm. So, while wearing it, it will dispel the static that the human body produced at any time. Keep the static in the human body within a level harmless to health.And before you touch objects, dispel the static on those objects in order to prevent you from being hit to by the static.(Its speed of dispelling the static is enough to dispel the static of both sides before your hands meet the other side.) It has many kinds of ways of wearing, you can choose according to the need. Using it, you can totally get rid of the interference of the static. Function Wide range: FA service range covers an area within a 30cm radius from this product which can be used for human body, vehicle, electronic product, hardware, etc. (The actual service range depends on the environment of use) Fast: Static electricity can be eliminated within 0.2 second. Good effect: completely clear up the static hazard. Safety: This product is absolutely safe without any poison and hazard. Usage Just wearing the discharger, it will automatically eliminate static. There are many wearing ways: ó+ Wear on the wrist (recommended wearing way); ó+ Hang on body; ó¦ Put into pockets; When meeting static, the static indicator light will show, then static hazard has been eliminated. The Detail Specificationú¦ Color ú¦(shell+face) silver+blickíówhite+redíówhite+whiteíówhite+orangeíópink+pink Customized Productú¦ Negotiation OEM: 10,000 more Silkscreen: Yes (above 1000) Quality / Safety Certification: CE ROHS PS: The static hazard Ø Static may cause all kinds of cardiovascular disease (arrhythmia, tachycardia,etc.); Ø Static may cause myocardial infarction or cerebral thrombosis for the elderly; Ø Static may cause pregnant women in progesterone levels dropped to abortion or premature, or even to fetal deformity; Ø Static may inhibit male hormones of the elderly, and cause the sex dysfunction; Ø Static may cause premature senility; Ø Static may cause headache, insomnia, palpitation, nausea heart, psychological Ø Static may cause skin dryness, allergies, itch,erythema and pigmentation. Ø Static can cause electronic products injury, shorten usage life and cause fires etc. Product specificationú¦4.5cm*3cm*1.5cm Pack the way ú¦B=B Corrugated Carton
Product Description - Crusher Price of product ( USD price or FOB price) - RS 20000.00
ZJB-DT is highly intelligent battery charge and discharge tester. It can be used as the discharge load in the battery off-line state, and realize the constant discharge of the set value by continuously regulating the discharge current. the tester records all valuable and continuous real-time data during the process. Friendly HMI provide a variety of configuration and data review, user can download record data to USB. PC host operation software can generate the curves and reports needed. Intelligent SCM ARM control, 7-inch 1024*600 LCD display. �· Discharge load use PTC ceramic resistor, avoid red heat for a safer discharge process. �· Remote battery data collector use wireless, multiple band design for 4 device working in one site. �· Each device support max 25 cell collection boxes, each box connect 12 batteries, total 300 battery cell detecting. User free to configuration charge/discharge termination threshold. Provide software export record & curve report for further analysis. Various alarm function, provide automatic protection in over-temperature/voltage/current status. With RS485 port for remote control
PDG-1000 provide continuously monitors of partial discharge (PD) in equipment such as transformers, cables in switchgear and rotating machines etc. It analyzes RF emissions in the HF, VHF and lower UHF ranges by sensors outside the cabinet. HMI unit provides site display of TEV amplitude, ultrasonic amplitude, DO port can drive local alarms, Multi-level alarm notice site engineer. PDG-1000 also can communicate data and notifications across standard RS485 modbus interface to networked supervisory systems. Rugged, compact design sensor detect TEV and audible ultrasonic. Non-intrusive and wall-mounted unit design, magnetic adsorption easy installation. Panel mount HMI unit provide automatic PD data acquisition and analysis. HMI support max 96pcs sensor, optional wireless and wired(RS485) connection. Multiple configurable alarms, provide 2*DO NC & NO contact for external alarm trig. RS 485 MODBUS-RTU easy integration into existing SCADA systems.
Product Description ESD simulator guns (Electrostatic Discharge Generator/Electrostatic Gun/ESD Guns) is in full compliance with IEC 61000-4-2, EN61000-4-2, ISO10605, GB/T17626.2, GB/T17215.301 and GB/T17215.322. What is a ESD test? The static electricity generated by the human body to the object or between two objects may cause the electrical and electronic equipment circuits to malfunction or even be damaged. The ESD generator is designed for the withstanding ESD performance measurement for the assessment of electrical and electronic equipment. ESD61000-2/ESD61000-2A has a LCD touch screen in both English and Chinese. What is an esd simulator gun used for? Electrostatic discharge simulator is highest electrostatic voltage can be up to 30 kv, which is enough to cover the most severe standard grade of electrostatic voltage requirement (the voltage requirements of the grade 4 air discharge electrostatic is 15 KV). The ESD test gun can be used for the most of electrical and electronic equipment for electrostatic discharge test, and also can ensure comparability and reproducibility of test. Specifications: Product Model ESD61000-2 ESD61000-2A Output Voltage 0.1~20kV ±5% 0.1~30kV ±5% Polarity Positive/Negative Positive/Negative Energy Storage Capacitance 150pF ±10% (Replaceable)
Product description Partial discharge comprehensive analyzer is the dedicated product to measure and analyze the insulation ability of electrical equipment. This system adopts modern electronic and computer integrated technology with the functions of signal amplification(analog signal, electronic signal, digital signal), filtration, data sampling, data processing, figure display, test report generation automatically so that it may finish the measurement, location and analysis of the partial discharge. Technical index Technical characteristics Number of interfaces Free-running 4 interfaces Sampling rate 1M. 5M. 10M selected Sampling accuracy 12bit Range changing -40dB, -20dB, 0dB, 20dB, 40dB ,60dB, totally 6 types Measurement frequency range 3db bandwidth 10kHz 1MHz Digital filtering 10kHz 1MHz freely selected Program controlled filter subsection Nonlinear error in the range 10% Measurement range 0.1pC~100,000pC Sensibility 0.1pC Capacity range of the measured product 6pF 250 F Frequency range of test power 50 500Hz Display Display screen 12 TFT true color touchable LCD screen Resolution 1024 768 Interface USB 3 types, use of external mouse, keyboard or other USB devices. Power mode AC 220V; Frequency 50Hz; Power 300W Electric signal interface 4 BNC interfaces, use of signal input. Optical signal interface 4 types, use of signal input Network interface 1 type Landing button External landing General instruction CPU Basic frequency 1.60GHz Ram 2.0GB Hard disk 128GB SSD System Windows Xp Operating environment Size Weight 15.8kg
Product description Partial discharge inspection instrument is a digital partial discharge charged detection instrument designed by our company based on years of experience in partial discharge measurement. It adopts two emerging technologies, ultra high frequency (UHF) measurement and ultrasonic (US) measurement. This system uses modern electronic and computer integrated technology to realize signal amplification, filtering, data acquisition, data processing, partial discharge parameter calculation, map drawing, and automatic generation of test reports, thereby completing the intelligent measurement and analysis of partial discharge. This device adopts handheld design and Wince system development; the device is lightweight, convenient to carry, fast to measure, and easy to use on the spot; it has friendly interface, simple operation, and high refresh rate; and the device has complete functions, strong anti-interference ability, and accurate measurement. This instrument has no damage to the power equipment to be tested during the testing process, and has no impact on the operation of the equipment. According to the maps obtained by the multiple detection modes of the UHF and US methods, the diagnostic analysis of the detection of insulation defects or hidden dangers of power equipment can be performed to clearly determine the operating status of the power equipment. Technical index Host parameters Number of interfaces 2 interfaces 1 UHF interface 1 US interface Sampling accuracy 12bit Way of synchronization Internal synchronization,External synchronization, Light synchronization UHF parameters Measurement frequency range 300MHz-1.5GHz Output method Output with SMA head Receiving method Receive with antenna Transfer method Coaxial cable Sensitivity 70dB Mean sensitivity 50dB Dynamic Range 80dB Hardware Display screen 4.3 TFT true color LCD screen Resolution 480 272
Product Introduction: Arrester Discharge Counter Calibrator is used for discharge action logger inspection and verification of discharge counter in valve-type arrester including silicon carbide common valve type (FZ and FS), silicon carbide magnetic blow valve-type (FCZ and FCD) and zinc oxide arrester. It is used to verify the reliability of various lightning arrester counter actions. The reliability of the counter action is very important to the power system. It is an important parameter to record the number of lightning strikes by the lightning arrester in normal operation. It can provide the staff of the power system with an important basis for the targeted inspection of the arrester. This instrument is mainly used for high-voltage arresters above 35kV. Product Parameters: 1.Ambient temperature 2.Relative humidity 3.atmospheric pressure:86 106kPa 4.Discharge test voltage: 2kV 5.Charge time: 1 minute