Golden Vac plasma blood collection tube promises to provide non-polluting and non-differential original blood specimen for medical test. After centrifugation, plasma can be separated from blood cells effectively. Plasma tube includes 5 kinds of tubes: Clotting Tube with blue cap, Heparin Tube and Gel & Heparin Tube with green cap, Compound of Sodium Fluoride and Anticoagulant Tube with grey cap, Gel& EDTA Tube with lavender cap. GLUCOSE TUBE Compound of Sodium Fluoride and Anticoagulant Tube aims to obtain highly stable plasma for blood glucose testing. Sodium Fluoride is a kind of inhibitor of glucose degradation, it has the function of repressing glucose metabolism and degradation. Optional Anticoagulant are Potassium Oxalate, EDTA and Heparin, they could prevent blood coagulation and avoid blood hemolysis. This particular compound additive realise that blood glucose specimen could be cold storage for a long time. Item GD020SFH, Specification Gray cap, Sodium Fluoride + Heparin Sodium , 13*75mm, 2ml, Item GD030SFH, Specification Gray cap, Sodium Fluoride + Heparin Sodium , 13*75mm, 3ml, Item GD040SFH, Specification Gray cap, Sodium Fluoride + Heparin Sodium , 13*75mm, 4ml, Item GD050SFH, Specification Gray cap, Sodium Fluoride + Heparin Sodium , 13*75mm, 5ml, Item GD020SNA, Specification Gray cap, Sodium Fluoride + EDTA Na2 , 13*75mm, 2ml, Item GD030SNA, Specification Gray cap, Sodium Fluoride + EDTA Na2 , 13*75mm, 3ml, Item GD050SNA, Specification Gray cap, Sodium Fluoride + EDTA Na2 , 13*75mm, 5ml, Item GD020SP, Specification Gray cap, Sodium Fluoride + Potassium Oxalate , 13*75mm, 2ml, Item GD030SP, Specification Gray cap, Sodium Fluoride + Potassium Oxalate , 13*75mm, 3ml, Item GD040SP, Specification Gray cap, Sodium Fluoride + Potassium Oxalate , 13*75mm, 4ml, Item GD050SP, Specification Gray cap, Sodium Fluoride + Potassium Oxalate , 13*75mm, 5ml, Item GD6001, Disposable ESR Pipette with prefilled (3.2% Trisodium Citrate and capped filling tube 100pcs / box *10 boxes
Supplier: Medical disposable equipment, medical devices, surgical equipment, icu, ccu, iccu, sicu, micu equipment and devices along with pathology equipment etc. all medical devices used in any healthcare landscape, 100ml plastic Beaker 500ml plastic Beaker, Measuring cylinder 250 ml plastic, Measuring cylinder 500ml plastic, Measuring cylinder1000ml plastic, Forceps 10X13X20mm without tooth, Pipette- 100-1000, Pipette- 1 - 10 ul -1unit, Pipette - 10 - 100 ul unit, Small tips( 2-200ul), Large tips, Tuberculin syringe, Disposable syringe 2 ml, Disposable syringe 5 ml, Disposable syringe 10 ml, Petri dish plastic Dimension 150mm, Sterile Injection Water, Glass test tube 5 ml, Glass test tube 25 ml, Plastic test tube 5ml, Surgical mask, Surgical Cap, Disposable Gloves Small, Disposable Gloves plastic, Disposable Gloves Large, Improved Neubar chamber, Kimtech Multipurpose Reusable Cleaning Cloth ,low lint & High Absorbent wiper ,50 sheet ,Bule color (23.7 cm x25.4 cm), Lab Coat 70% Isopropanol Alcoh
Uncut Sheet HBsAg Rapid Test Package:30sheets/pouch Specimen:Whole blood/Serum/Plasma FOR THE QUALITATIVE ASSESSMENT OF HBsAg IN HUMAN SERUM, PLASMA OR WHOLE BLOOD INTENDED USE The HBsAg Rapid Test is a Chromatographic immunoassay (CIA) for direct qualitative detection of Hepatitis B type virus surface antigen (HBsAg) in human serum /plasma and whole blood. PRINCIPLE The HBsAg RST is a chromatographic immunoassay (CIA) for the detection of surface antigens of Hepatitis B in human serum/plasma and whole blood. Specific antibody against HBsAg is pre-coated onto membrane as a capture reagent on the test region. During the test, specimen is allowed to react with the colloidal gold particles, which have been labeled with anotherr specific antibody. If HBsAg is present, a pink colored band will develop on the membrane in proportion to the amount of HBsAg presented in the specimen. Absence of this pink colored band in the test region suggests a negative result. To serve as a procedural control, a pink colored band in the control region will always appear regardless the presence or absence of HBsAg. REAGENTS AND MATERIALS PROVIDED 1.One sealed pouched cassette with desiccant and a disposable pipette.. 2.Blood diluent in a dropper bottle. Store at 2-8°C. 3.One piece of operating instruction with 40 test pouches..
Product Details: Brand : ACON Cat. No : OCP10s S.No Code Size Test Strips 1 G133-111 50 On Call Plus Blood Glucose Test strips 2 G133-119 200 On Call Plus Blood Glucose Test strips Designed By ACON Labs USA For over 23 years, ACON Labs has led the way in making high-quality diagnostic and medical devices more affordable to people all around the world. Headquartered in San Diego, California, the US office is the centre of strategic management, innovative research and development. Beep Function Early Detection of Hypoglycaemia Post Surgery Sugar Monitoring Monitoring Blood Sugar at Home Monitoring Blood Sugar at Hospital Accurate Results Technology conceived and designed by ACON Labs USA ensures accurate reliable blood sugar tests recommended by Doctors for patients at home and hospitals. Minimal Blood Sample Required The On-Call Plus Technology is so sensitive only 0.4 Micro Litre of Blood Sample is required to process the blood sugar Results Quick Results in 10 Seconds. On Call Plus Starter Kit The Starter Kit has been designed for new users of Glucometer to ensure proper monitoring of blood sugar levels. Hospitals Clinics Home Care Elderly Pregnant Women.
Product Details: Type : 50 test/100 test Brand : Roche Product highlights Helps to determine blood sugar level Gives accurate and reliable results Useful for both Type 1 and Type 2 Diabetes Provides results in approximately 5 seconds Proven Accuracy: The Accu-Chek Active strips help you to keep tabs on your diabetes regularly. It also fulfils ISO 15197:2013 standards of accuracy. Clever functionality: Accu-Chek Active strip is a hassle-free product. The blood spreads across the strip and is automatically absorbed by it. The system then provides a fast and accurate result. Easy-handling: A clear protective barrier runs along the entire length of the test strip to protect the strip, making it easy to use. Blood volume: 1-2 �¼l Visual double-check: To ensure accurate blood glucose measurement, Accu-Chek Active allows you to double-check the displayed result. Out of meter dosing: Test strip outside the meter: approx. 08 seconds
Product Details: Brand : Siemens Product Type : Test Card Cat. No : 10736515 10736515 Siemens EPOC BGEM BUN Test Cards, PKG/25 Tests Siemens Healthineers Epocâ?¢ BGEM Test Card enables the epoc perform 13 different tests simultaneously on a single card Description Expansive test menu paired with accuracy and speed are critical to the Epocâ?¢ One test card with 13 analytes for improved inventory management and reduced waste. Room-temperature storage. Single use, with automatic calibration prior to analysis. Error-free test panel recognition with bar-coded lot number and expiration. Small sample size: Requires only 92 AUL blood sample.
Supplier: Laboratory disposable plasticware used in research, tissue culture plates and flask, centrifuge tube, glass bottom dish, pipette tips, elisa plate, pcr plate, deep well plate, cryo vials , nitrile gloves , humidifier,whatman filter paper,
Both glass and PET tubes of all types, 13x75mm, 13*100mm, 16x100mm. 100pcs/rack, 1200pcs or 600pcs/ctn.
Supplier: Medical consumable products, such as disposable virus specimen collection samplers and saliva collection kits, vacuum blood collection tubes, pipette tips