Float switches are used to monitor liquid levels by opening or closing when a desired action point is reached. A variety of types are available using mercury and non-mercury tilt switches and, also, permanent magnets and reed switches. Common applications include sumps, pump-control systems, bilge pumps, below ground vaults and irrigation systems. 14"x9"x12"
Tilt switches are used to sense movement (tilt) of a device above and below a horizontal axis. A typical use is in a thermostat. A glass mercury switch is mounted to a bi-metallic spring which expands and contracts with temperature. As the spring moves, the switch contacts pass through the horizontal plane, opening or closing to operate the furnace or boiler. The angle through which the switch must move for proper operation -the differential angle- is measured from the point of just make to just break; it is specified as a maximum. When selecting a tilt switch, it is important to ensure that the operating mechanism can move the switch through an angle greater than the differential angle. Some additional applications include: level controls, appliances, security alarm systems, toys and games, float switches and water-treatment equipment (non-mercury). 14"x9"x12"
M-ELL-SA External level switch is a non-contact level switch by using the Variable frequency ultrasonic technology, it is widely applied to all kinds of liquid level detection. The measuring probe is installed on the external wall of the container. And it belongs to a completely non-contact instrument which measure the level from outside of tank. Working Principles of the External Level Switch The measuring probe of the instrument can send the ultrasonic and detect the residual vibration signal in the wall of the container. The amplitude of the residual vibration signal will becomes smaller when the liquid is over the probe. A switch signal will be outputted after such change is detected by the instrument. The Variable Frequency Ultrasonic Technology is invented by the DingHua and it is the world¡¯s leading ultrasonic signal change detection technology. The main problem for the traditional ultrasonic level switch is that the ultrasonic signal can be interfered by the attachments from the tank wall and the amplitude of residual vibration signal can be changed by the drift of the temperature and time, thus the misinformation phenomenon is easy to appear. More owned the patent of self adaptive ultrasonic technology of variable amplitude variable frequency and it can effectively eliminate the interference and drift to test the changes of the signal correctly. So that it can be applied to a variety of complex site conditions, stable and reliable long-term work. This product adopts the "micro vibration analysis" external sonar signal processing technology and leading manufacturing process, and ensure the reliability and durability of ELL-SA external variable frequency ultrasonic level switch. Application There is no need to open a hole on the tank wall to install the sensors when the ELL-SA series external level switch is installed. The instrument neither contact the liquid medium nor contact the gaseous medium in the container. Therefore, the installation is simple and quick, safe and secure. No need to clear the tank while repair and maintenance, no influence on the normal operating. ELL-SA series external level switch is applicable to fixed-point liquid level measuring and alarm of all kinds of containers and liquid. It can be widely used in petrochemical, chemical, oil depots, oil, electricity, liquid storage, pharmaceutical and other industries. And it has a significant advantage in the pressure vessel, dangerous chemical liquids, flammable and combustible liquids and fixed-point liquid level measuring and alarm fields. Product features 1¡¢Safety: the valves, communicating pipes, joints are not used in the measurement of poisonous, corrosion, pressure, easy to bums, volatile and leak liquid, and there is no leaks, no contact with the liquid and gas in the container, which is very safe. Even under the condition of instrument damage or repair, there will be no possibility for leakage, poisoning and explosion. (Measuring principle diagram) 2¡¢Easy installation and maintenance: There is no need for tank cleaning and open fire during the installation, no impact on production 3¡¢Durability and reliability: There is no mechanical moving parts in the sensor and instrument, strict sealing, isolation, will not wear or corrode. 4¡¢Widely applicable: It has nothing to do with the medium pressure, temperature, density, dielectric constant, viscosity, and presence of corrosion. carton box and gift box, according to requirement
Supplier: Liquid level sensors, float switches,mechanical gauges
Supplier: Industrial indicator light, signal digital indicator digital meter, industrial electronic indicator digital meter, electrical push button switch, floating ball, button light accessories
Supplier: Float switch, control panel, control box, level alarm, pressure transmitter.
Buyer: micro-switch, plastic resin, PCA
Supplier: We can offer: 1/ flow series: electronic flow switch, intergrated flow temperature transmitter,piston flow switch, baffle flow switch,electronic turbine meter etc 2/ level series:� electronic temperature level sensor, float level switch, floating ball level switch, capacitive level switch, electronic level switch etc 3/ pressure series: electronic pressure switch, mechanical pressure switch, diffused silicon pressure transmitter etc 4/ temperature series:� electronic temperature switch, temperature switch, mechanical temperature switch,� intergrated� temperature transmitter etc
Supplier: float switch, liquid level sensor, water level controller, coil heaters, cartridge heater, band heater, flow switch, pressure switch, foot switch,etc electric products
Supplier: Vehicle speed sensor, vr speed sensor, hall effect sensor, water in fuel sensor, fuel indicator, float sensor, vibration limit switches, limit switches, snap action micro switches, water proof rocker switches