ST series generators are mainly designed to serve as power generating unit of small capacity, which supply electricity for lighting purpose in ships, for house-hold electric devices used in towns or villages. The construction of the generators is of dripproof, salient pole rotating field self excitation and constant voltage type. The alternator interior is used with high quality electric magnetic and electrical materials. Stator insulation is class B. These generators are elegant in appearance, tight in construction and easy maintain. IEC standard are adopted on dimension, these dimension are suitable for using in Australia, Europe, America and other countries with the end covers to be model B.
Supplier: Motor, generator, engine, generating sets, water pumps, fcu motor
We can supply generator made by CATER PILLAR , USA This generator was made in 2006 but it has been kept for emergency use only and it did not operate long time. and it is almost new one. We welcome testing by engineers.
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 200 Engine Model : 1106A-70TAG3 Stand By kVA: 200 Stand By kW : 160 Prime kVA: 182 Prime kW : 145 Rated Current : 262 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Model 1106A-70TAG3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 180.2 / 243,5 Prime Power Hp 162.7 / 220 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 41,5 Lt %75 LOAD 31,8 Lt %50 LOAD 20,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 33 Engine: PERKNS Engine Model : 1103A-33G Stand By kVA: 33 Stand By kW : 26,4 Prime kVA: 30 Prime kW : 24 Rated Current : 43,2 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKNS Engine Model 1103A-33G Number of Cylinders 3 Inline Injection System Direct Compression Ratio 19.25:1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 8,3 Standby Power kw / Hp 30,4 / 41 Prime Power Hp 27,7 / 37,3 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 8 Fuel Consumption (lt / h) Lt Full Load 7,2 Lt %75 LOAD 5,6 Lt %50 LOAD 4 Frequency Hz Power kVA 33 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 980 Weight (Open) Kg 825 Width (Silent) Mm 900 Length (Silent) Mm 2200 Height (Silent) Mm 1350 Fuel Tank Capacity Lt 135 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
Supplier: Air compressors, automation equipment, bearings, cables, diesel engines and generators & machinery spare parts, filters, electrical equipment's, electric motors and gear motors, panel boards and & much more.
Services: Logistics, customer clearance and much more.
Buyer: Air compressors, automation equipment, bearings, cables, diesel engines and generators & machinery spare parts, filters, electrical equipment's, electric motors and gear motors, panel boards and & much more.
FP 250 Engine Engine Model : 1206A- E70TTAG2 Stand By kVA: 250 Stand By kW : 200 Prime kVA: 227 Prime kW : 182 Rated Current : 327 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1206A- E70TTAG2 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 15.08:1 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged aftercooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 226 / 303 Prime Power Hp 204 / 273 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 25 Fuel Consumption (lt / h) Lt Full Load 50,6 Lt %75 LOAD 37,9 Lt %50 LOAD 25,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2550 Weight (Open) Kg 2120 Width (Silent) Mm 1300 Length (Silent) Mm 3900 Height (Silent) Mm 1980 Fuel Tank Capacity Lt 450 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.