Sv-5q automobile tail gas analyzer 1. Measurement range: co: 0-10.0 10-2(%) Co2 : 0-20.0 10-2 (%) Hc: 0-10000 10-6 (ppm) O2 : 0-25.0 10-2 (%) No: 0-5000 10-6(ppm) Petrol temperature: 18f¦-150f¦ Engine speed: 100-20000rpm 2. Repetitiveness: f_f+2% 3. Zero point floating: co:f+0.06 10-2(%)/1h Co2: f+0.5 10-2(%)/1h Hc:f+30 10-6(ppm)/1h O2: f+0.5 10-2(%)/1h No: f+30 10-6(ppm)/1h 4. Crossing floating: not over the permitted indicated error range (1hour) 5. Indicated error: co: f+5%(relative error: 0-10%) Co2: f+5%(relative error: 0-20%) Hc:f+5%(relative error: 0-4000ppm) f+10%(relative error: 4001-10000ppm) O2: f+5%(relative error: 0-25%) No: f+5%(relative error: 0-5000ppm) 6. Environmental condition: petrol temperature: f+2f¦(relative error) Engine speed: f+1.0%(relative error) Temperature: 0f¦-40f¦ Humidity: f_80% Atmospheric pressure: 60-105kpa Power: ac 220vf+10%, 50hzf+1hz 7. Preheat time: 10 minutes 8. Method of sample taking: Tail gas: taking directly, and the length of sample pipe and probe are 5m and 900mm Petrol temperature: put the probe into the hole of lubricating oil gauge of engine, and the length of probing is the length of oil gauge. Then seal it with stopper in order to avoid the leakage of oil. The pipe length is 5m Engine speed: the result is available at the point no more than 20cm from the high voltage coil of engine 9. Display method: lcd large screen display 10. Optional configuration: gas temperature and engine speed 11. Main features: built-in printer, and computer network communications, 30 minutes automatically suggest zero. Idle and idle-two measurement methods, plates imported functional group can store 500 measurements, natural gas, liquefied petroleum gas and petrol fuel three choices. Carton
Svqd-100c automatic vehicle headlamp detector Nmain technical feature: 1. Temperature: -5¦-40¦; 2. Relative humidity: 20%-85%; 3. Power: ac220v+10%, 50+1hz; N measurement range: 1. Intensity: 0-120000cd 2. Far light: Vertical angle: up: 40cm/10m- down:56cm/10m; Level angle: left: 56cm/10m- right: 56cm/10m; Near light: vertical angle: up: 40cm/10m- down:56cm/10m; Level angle: left: 56cm/10m- right: 56cm/10m; Measurement of light: 450-1350 (mm); 3. Indicated error: Detection height: + 10mm; Intensity: + 12%; Deviation: + 35mm/dam; Photoelectric box center height: +1cm; 4. Detection distance: 1 m; 5. Weight: 110kg(weight of mainframe); Carton
Brief introduction: Sv-2lb semi-automatic smoke meter has a high light led screen with light conduction controlling. The average data after three times' test can be displayed, and the equipment can be connected with computer through rs-232 plug. Function of automatic air bleed made the compressed air is not in need. -n main technical feature: 1. Measurement range: 0-10(rb) 2. Effective diameter of filter paper: ¦ª32mm 3. Time for air bleed: 1.4 f+0.2s 4. Quantity of air bleed: 330 f+15ml 5. Resolution: 0.1(rb) 6. Indicated error: no more than f+3% of the full stroke 7. Repetitiveness: no more than f+2% of the full stroke 8. Stability: continuous working within 3h, with floating quantity no more than f+3% of the full stroke 9. Environment condition: temperature: 0f¦ -40f¦ Relative humidity: 20% -80% Atmospheric pressure: 70-105kpa Power: ac220v f+10%; 50hzf+1hz 10. Method of air bleed: air bleed by electricity 11. Display method: led high light display 12. Main features: connect with computer Carton
Sv-5y opacimeter 1. Measurement range: non-transparence n: 0-99.9%; Ray absorption coefficient k: 0-16.06m-1; Petrol temperature: 0¦-150¦; Engine speed: 100-20000rpm; 2. Resolution: non-transparence n 0.1%; Ray absorption coefficient k 0.01m-1; Petrol temperature: 1%; Engine speed: 1rpm; 3. Indicated error: non-transparence n:+2.0%(absolute error); Petrol temperature:+ 2¦(absolute error); Engine speed:+ 30rpm (absolute error); 4. Power: ac220v+10% ; 50hz+1hz; 5. Weight: control unit: 5kg(include printer); Test unit: 7.5kg; 6. Effective optical path length: 215mm+0.1mm; 7. Preheat time: 15 minutes; 8. Method of sample taking: Smoke: taking directly, and the length of sample pipe is 2m. Petrol temperature: put the probe into the hole of lubricating oil gauge of engine, and the length of probing is the length of oil gauge. Then seal it with stopper in order to avoid the leakage of oil. The pipe length is 5m. Engine speed: speed folder will be fixed on the engine nozzle can be tightened 9. Display method: lcd large screen display 10. Optional configuration: gas temperature and engine speed; 11. Main functions: built-in printer, and computer network communications. Number plate input feature can be stored to 500 measurements, k-value exceeding alarm. Carton
1.Diameter probe: 8mm, 6mm, 4mm(hard probe) 2.Probe types: soft and hard probe. 3.Working length: 1100mm(soft probe)/170mm-500mm(hard probe) 4.Observation: straight/side. 5.Light: built-in adjustable intensity halogen cold light source. 6.Bend angle turn: two bends: up and down: 90-120 7.Optional configuration: observing the lens/introduced lcd screen Carton
Sv-2lz automatic smoke meter 1. Measurement range: 0-10(rb) 2. Effective diameter of filter paper: ¦ª32mm 3. Time for air bleed: 1.4f+ 0.2s 4. Quantity of air bleed: 330 f+15ml 5. Resolution: 0.01(rb) 6. Indicated error: no more than f+3% of the full stroke 7. Repetitiveness: no more than f+2% of the full stroke 8. Stability: continuous working within 3h, with floating quantity no more than f+3% of the full stroke 9. Power: ac 220v f+10%, 50hzf+1hz 10. Method of air bleed: air bleed by electricity 11. Display method: lcd large screen display; 12. Main features: connect with outer printer and computer; Auto alarm for lack of paper; Auto paper pass, test, reset and clean. Carton
The FK-5-1-12 Clean Agents, also known as NOVEC1230 Fire Suppression Agents, is a highly efficient and reliable hydro-fluorocarbon fire extinguishing solution. This product is designed to quickly and effectively suppress fires in various settings while being non-toxic, environmentally friendly, and safe to use. Model Number: FK-5-1-12 clean agents Product Name: NOVEC1230 Fire Suppression Agents Reliability: High Model NO.: FK-5-1-12 clean agents Application The FK-5-1-12 Clean Agents is suitable for use in various applications, including but not limited to: Commercial buildings Industrial facilities Data centers Telecommunication rooms Museums and art galleries Power generation plants Server rooms Control rooms Storage facilities
Supplier: Smoke detector, smoke detectors, alarms, home security, security system, carbon monoxide sensor, carbon monoxide detector, gas sensor, gas detector, gas detection, water leak detector, water alarm
Supplier: Gas detector, alarm system, smoke detector, gas sensor, home alarm, security alarm, gas detection, gas alarm, intelligent security system, personal wireless fire alarm, smoke alarm, co/carbon monoxide detector sensor, household gas analyzers