Generator engine controller panel and controller We are professional manufacturer and exporter of generator engine controller panel and controller. With the quality goods and competative prices, we have established fine reputations in this industry. Should you need a reliable supplier, please contact us:joy young enterprise co., ltd. Tel:886-4-7795189 fax:886-4-7793959 no. 83, wan shou road, lu kang, chang hua, taiwan. E-mail:superstar8889@seed.Net.Tw Standard exporting
We are available with the following spares of Generator engines: ALLEN:- (W.H ALLEN) (BCS 12 DX), (BCS 12 EX), (S12F),(16S37F),(S37) BERGEN-ROLLS ROYCE (V 28 L/LU), (L 23/30), (S28 LH)), (T 23 LH), (T 23 HH), L 28/32, MTBH 40, MTBH 30,BRM,KRMB,KVGB,KVMB,KRG. HIMSEN-HYUNDAI H25/23, MIRRLEES BLACKSTONE E Series, ESL,MK3,KMR,ESTL. MWM TBD 23,TBD 444, TBD 510,TBD 604,TBD 620, CATERPILLAR D 343, D 3406, D 3512, D 379, D 398, D 399, 3506, 3512, 3516, 3616. DAIHATSU DL-20, DL-22, DL-24, DL-26, DL-28, DL-32, DS-32, DS-26, DS-22, DS-18, DS-26A, DV-26, VS/26, PS-26, PS-26H, PS-22, PS-20 DEUTZ SBV 6M 428, SBV 8M 428, SBV 12M 428, SBV 6M 528, SBV 8M 628, SBV 12M 628, M 540, M 545, M 358 FIAT GMT FIAT GMT B230.6, FIAT GMT A420.6, FIAT GMT A420.8, FIAT GMT A420.12 FUJI FUJI G.27.5, FUJI M 27.5,FUJI L 27.5G,FUJI G.32 SULZER S20, ATL25, AL20/24, AL25/30, ASL25/30 SKL VDS48/42AL-2, NVD48-2U, VD36/34, NVD36, VD26/20AL-2, NVD26-2, VD26/20AL-2, 16/18, 18/21, VD20/24, VD24/24, VD26/20AL, VD36/24, NVD36, NVD48 CUMMINS QSK,QSX,KTA,VTA,NTA,BTA,GBT NIGATA L-25-BX, L-25-MG, M-31 MG, MG32CLX, MG41HX NOHAB DIESEL:- NOHAB POLAR. SF 116 VS, SF 212, V216, F 312, F 216, F 24 RUSTIN ATCM, AT350, RK3CM, RK270 EMD EMD 645, EMD 710. WARTSILA R32D, R32E, V32D, V32E, R22, R22HF, R22/26v, L-20,L26 414 TS, 424 TS, 524 TS, 624 TS, 824 TS STOCK WERKSPOOR DIESEL:- ( S W D) FAH D 240, SW 280, DRO 120, DRO 216 K, DRO 218 K YANMAR N 18, N 21,EY 18,EY 22,EY 26, Z 280, M 200, M 220, M 220 AL ET, M 220 AL ST, M 220 AL SX, M 220 AL UT, T 220, T 220AL ST, T 220 AL UT, T 240, T 240 EX, T 240 ST, T 240 L SX, T 240 L UT
Engine model R4105ZD Manufacturer WeifangTianHe Diesel Engine Co., Ltd Brand TH Type Water cooling , four stroke, swirl chamber or direct injection, inline. Rated power(kw) 56KW 62KW Engine speed (rpm) 1500rpm 1800rpm Bore * stroke(mm) 105*115 Number of cylinder 4 type Diect injection, water cooling ,four stroke, inline. Compression ratio 16:1 Fuel consumption221g/kw.h Oil comsumption1.63g/kw.h Speed governor Mechanical or elec govenor Starting method Electric starting, 12V or 24V Cooling method Forced water cooled Lubrication method Forced lubricating Exhaust gas temperature600°C Net Weight 480 Application Diesel generator set
The generator powered by Honda Yamaha Robin engines.
EAP 220 Engine: Engine Model : 1106A-70TAG4 Stand By kVA: 220 Stand By kW : 176 Prime kVA: 200 Prime kW : 160 Rated Current : 288 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Engine Model 1106A-70TAG4 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 18 Standby Power kw / Hp 196.3 / 265 Prime Power Hp 178.9 / 242 Fuel Type Euro Diesel Governor System Electronic Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 45,8 Lt %75 LOAD 34,7 Lt %50 LOAD 23,1 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 DIMENSIONS Weight (Silent) Kg 2270 Weight (Open) Kg 1940 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 200 Engine Model : 1106A-70TAG3 Stand By kVA: 200 Stand By kW : 160 Prime kVA: 182 Prime kW : 145 Rated Current : 262 Engine heavy duty diesel engine 12V starter and charge alternator Replaceable air, fuel and oil filters Mechanical governor control Tropical type radiator Flexible fuel hose Oil drain valve and extension hose Industrial type silencer and steel compensator Maintenance-free starter battery Water jacket heater 1500 rpm engine speed Alternat IP 21-23 Protection Standard H Insulation Class 50 Hz Frequency 4 pole brushless synchronous type alternator Automatic Voltage Regulator (AVR) 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis Convenient design for easy lifting and carrying High standard sound proof canopy design Modular design with easily removable nuts - bolts Lockable doors Transparent window for watching Control Panel Electrostatic powder painted, providing protection against harsh weather conditions Emergency STOP button Fuel tank inside the chassis Anti-vibration wedges (engine - chassis and chassis ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine Model 1106A-70TAG3 Number of Cylinders 6 Inline Injection System Direct Compression Ratio 16:01 Bore 105 Strok 135 Displacement Lt 7,01 Air Intake Turbocharged and air charge cooled Speed (RPM) 1500 Oil Capacity Lt 16,5 Standby Power kw / Hp 180.2 / 243,5 Prime Power Hp 162.7 / 220 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 22 Fuel Consumption (lt / h) Lt Full Load 41,5 Lt %75 LOAD 31,8 Lt %50 LOAD 20,2 Frequency Hz Power kVA 200 Voltage V 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 2190 Weight (Open) Kg 1850 Width (Silent) Mm 1200 Length (Silent) Mm 3500 Height (Silent) Mm 1850 Fuel Tank Capacity Lt 360 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
EAP 33 Engine: PERKNS Engine Model : 1103A-33G Stand By kVA: 33 Stand By kW : 26,4 Prime kVA: 30 Prime kW : 24 Rated Current : 43,2 Engine heavy duty diesel engine - 12V starter and charge alternator - Replaceable air, fuel and oil filters - Mechanical governor control - Tropical type radiator - Flexible fuel hose - Oil drain valve and extension hose - Industrial type silencer and steel compensator - Maintenance-free starter battery - Water jacket heater - 1500 rpm engine speed Alternat - IP 21-23 Protection Standard - H Insulation Class - 50 Hz Frequency - 4 pole brushless synchronous type alternator - Automatic Voltage Regulator (AVR) - 400/230V AC Output Voltage - 1500 rpm Sound Proof Canopy and Chassis - Convenient design for easy lifting and carrying - High standard sound proof canopy design - Modular design with easily removable nuts - bolts - Lockable doors - Transparent window for watching Control Panel - Electrostatic powder painted, providing protection against harsh weather conditions - Emergency STOP button - Fuel tank inside the chassis - Anti-vibration wedges (engine - chassis and chassis â?? ground) Optional - Thermal magnetic CB (for automatic models) - Super Silent Canopy - Mobile Generator Sets - Automatic fuel filling system - Synchronization panel - 3 Pole and 4 Pole ATS (Automatic Transfer Switch) - Fuel Heater, Oil Heater - External fuel tank and automatic fuel filling system - Fuel - water separator filter - Remote monitoring and control system Engine PERKNS Engine Model 1103A-33G Number of Cylinders 3 Inline Injection System Direct Compression Ratio 19.25:1 Bore 105 Strok 127 Displacement Lt 3,3 Air Intake Naturally Aspirated Speed (RPM) 1500 Oil Capacity Lt 8,3 Standby Power kw / Hp 30,4 / 41 Prime Power Hp 27,7 / 37,3 Fuel Type Euro Diesel Governor System Mechanical Cooling System Water Cooling Coolant Capacity Lt 8 Fuel Consumption (lt / h) Lt Full Load 7,2 Lt %75 LOAD 5,6 Lt %50 LOAD 4 Frequency Hz Power kVA 33 Voltage V 230 / 400 V Number of Phases 3 Automatic Voltage Regulator (A.V.R.) AS440 Voltage Regulation 1% Insulation Class H Protection Standard IP22-IP23 Power Factor 0,8 Weight (Silent) Kg 980 Weight (Open) Kg 825 Width (Silent) Mm 900 Length (Silent) Mm 2200 Height (Silent) Mm 1350 Fuel Tank Capacity Lt 135 1 Standby Power : The max power available during a variable electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage. Overloading isn t permissible. 2 Prime Power : The maximum power which a generating set is capable of delivering continuously whilst supplying a variable electrical load. Average load should be 70%. The generator can be overloaded 10% for 1 hour per 12 hrs.
50/60HZ,220/400V,water-cooled,1500/2000rmp/min,3phases,4wires, 20kwa-1000kwa,Power factor0.8 lag,open/silent type ATON is able to be your original equipment manufacture by using your authorized logo,brand name,graph design etc. over 1000kg
1) R3105CNGD1 (LPGD1): 26.5kW/1,500rpm, 50Hz 2) R3105CNGD2 (LPGD2): 30kW/1,800rpm, 60Hz 3) R4105CNGD1 (LPGD1): 42kW/1,500rpm, 50Hz 4) R4105CNGD2 (LPGD2): 46kW/1,800rpm, 60Hz 5) SAE3#/11.5" flywheel or double bearings 6) Used for 20-30kW generator set
Model Number: JE493G-15TA Engine Power -1500RPM: 36KW Frequency: 50Hz Cylinders: 4 Fuel Consumption (L/Hr): 10 Aspiration: Turbocharged Bore X Stroke: 93 * 102 Displacement: 2.771 Compression Ratio: 18.2:1 Governor Type: GAC Electrical