PIR motion detectors Rk210pr can be equipped with ra93 swivel bracket for ceiling, wall or corner mounting. Main features: Coverage is 10m Dual passive infrared detective technology True temperature compensation Dual polarity pulse count is adjustable Resist interference of white light Power consumption is low Professional optical pigmented lenses Installed on wall, ceiling or corner mounting Convenient for installation Pulse count is selectable Resist fluorescent interference Memory and form-c relay Smart and elegant design is ideal selection for residential installations Specification: Working voltage: 9-16vdc Working current: 12ma Contact of alarm: nc, 12vdc, 100ma max Contact of tamper: nc, 12vdc, 100ma max Time to alarm: 2.2s Time to warm-up: 2 minutes Rfi characteristic: 22v/m, 10mhz ~ 1ghz Working temperature: -5ºc ~ 50ºc Storage temperature: -20ºc ~ 55ºc Size: 89f-52f-39mm Height of installation: 2.3m Suitable swivel bracket: ra93
Control panel One installing code One (user) main code (can create duress code automatically) 8 gradable user codes Periodic test Offer testing report to alarm center automatically Peripheral eequipment With voice module Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port Events record 50 event records Memory when power is cut Digital voice module rv2006v 1 piece of voice message, time lasts 20s Follow-me number is assignable Timing function Auto daily arming Auto daily test report Monitoring function Trouble data can be displayed on keypad, and also can be transmited to central station Spare battery in low power Expansion module of power supply battery in low power Siren circuit in trouble Phone line failure Loss of ac Loss of auxiliary power System clock is not set Tamper prevention Fire alarm circuit in trouble Installation All expansion modules can be connected to the system by 4-line The distance is up to 300m between module and control panel Technical data Transformer: 16.5vac 40va Standby bettery: 12v4ah/ 12v7ah Auxiliary powerfg350ma Switch lockfg250ma Siren/bell sound outputfg750ma Led keypadf]rp205kp 3 keypad emergency zones: panic([1]+[2]), fire([4]+[5]), special emergency([7]+[8]) Led indicates the user functions and the installer programing Key-press with audible feedback Trouble display Led indication: alarm, power, armedfadisarmed, bypass, ready, tamper Backlight keys Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Up to 4 led keypads can be connected Mainboardf]rp205mb 5 zones of mainboard Special zones: zone-5 is fire zone Can be parted to 2 divisions11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor (2.2kf±[) Responding to various events Time to supervise is programmable Switch for power output Linkage output: nc, no, locked, or pulse Programmable output: 70ma 50 events records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma (max) Built-in digital clock Daily test report Disarm/arm report 4 led keypads can be connected to control panel, 4-line connection Built-in digital communicator Attached digital communicator, compatible to contract idfa4+2 2 central station phone numbers 4 follow-me phone numbers
Lcd keypad (rp208kcl) Display of 32 characters in two lines 3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8] Menu indicates the user functions and the installer programing Key-press with audible feedback System condition display Trouble display Led indication: alarm, power, armed, disarmed, bypass, ready, tamper User information is displayed on screen (except password) Lcd backlight Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Alarm memory display System trouble display Up to 4 lcd keypads can be connected Mainboardf]rp208mbf^ Zone terminal resistor (2.2kf±[) 8 zones of mainboard Expandable wired zone Special zones: zone-5 is fire zone, zone-6 is tamper zone 11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor Programmable output: 70ma Expandable to 4 large current output: 3a 50 event records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma max Built-in digital clock Daily test report Disarm/arm report 4 lcd keypads can be connected to control panel Circuit responding time of each zone can be set as 10ms, 500ms or 1s Mainboard has 7 types of fire alarm bell voice driver Connectible with four 1.5v 12a power supply expansion boards Mainboard has one 70ma programmable open circuit collector Connectible with 3a c-type programmble relay The distance is up to 1500m between module and control panel Siren voice output Siren voice type is programmble Current outputfg750ma(max) Auxiliary power output Auxiliary power output: 400ma Built-in digital communicator Attached digital communicator, compatible with contract idfa4+2 4 follow-me phone numbers 2 central station numbers Code One installing code One (user) main code (can create duress code automatically) 8 gradable user codes Periodic test Offer testing report to alarm center automatically Peripheral equipment With voice module Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port Power supply output expansion module eps Connect with system by 4-line Provide 2.5a, 12v power to other modules and siren Complete supervision of power supply condition, including battery, ac, siren circuit and auxiliary power output Digital voice module rv2006v 1 piece of voice message, time lasts 20s Follow-me number is assignable Timing function Auto daily arm Auto daily test report Disarm/arm rreport at window Monitoring function Trouble data can be displayed on keypad, and also can be transmited to central station Spare battery in low power Expansion module of power supply battery in low power Siren circuit in trouble Phone line failure Loss of ac Loss of auxiliary power System clock is not set Line communication is blocked Tamper prevention Fire alarm circuit in trouble Installation All expansion modules can be connected to the system by 4-line The distance is up to 1500m between module and control panel Technical data Transformer 16.5vac 40va Spare battery 12v4ah Auxiliary power supply 350ma Switch lock 250ma Siren 750ma
Lcd keypads (rp248kcl) Display of two lines and 32 characters 3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8] Menu indicates the user functions and the installer programing Key-press with audible feedback System condition display Trouble display Led indication: alarm, power, armed, disarmed, bypass, ready, tamper User information is displayed on screen (except for password) Lcd backlight Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Alarm memory display System trouble display Up to 4 lcd keypads can be connected Mainboardf]rp248mbf^ Zone terminal resistor (2.2k+[) 8 zones on mainboard Expandable up to 72 programmable zones Special zones: zone-5 is fire zone, zone-6 is tamper zone Can be parted to 8 divisions 11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor Programmable output: 70ma Expandable to 32 large current output: 3a 50 event records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma max Built-in digital clock Daily test report Function of end calling Disarm/arm report 4 lcd keypads can be connected to control panel Programmble voice for the siren output Current outputfg750ma(max) Auxiliary power output: 400ma Mainboard has 7 types of fire alarm bell voice drivers Connectible with four 1.5v 12a power supply expansion boards Mainboard has one 70ma programmable open circuit collector Connectible with 32 c-type programmble relays of 3a Circuit responding time of each zone can be set as 10ms, 500ms or 1s The distance is up to 1500m between module and control panel Built-in digital communicator Attached digital communicator, compatible with contract idfa4+2 2 central station numbers 4 follow-me phone numbers Code One installer code One (user) main code (can create duress code automatically) 8 gradable user codes Periodic test Offer testing report to alarm center automatically Peripheral equipment Expandable function of 32 lines relay output Disarmed/armed by romote control. Any zone can be programmed to be the switch lock port Rs232 port Expandable zone board 8 zones expansion module ez8 8 zones wiring expansion module Power supply output of switch lock Zones terminal: nc, no, single end with resistor (2.2k+[) Circuit responding time of each zone can be set as 10ms, 500ms or 1s 4-line connection, and easy for installation 8 zones wireless expansion module ew8 Wireless expansion module Time to supervise is programmable Monitoring of emitter in low power Tamper of emitter is supervised Indication of interfering signal Wireless detector is supported Verifying code by cycle 4 program output expansion module e04 4 lines programmable output(3a) Output: nc, no, locked or pulse Responding to various events Xto module supports x-10 agreement Power supply output expansion module (rp248eps) Connect with 5 modules by 4-line Provide 2.0a, 12v power to other module and siren Complete supervision of power supply condition, including battery, ac, siren circuit and auxiliary power output Built-in siren driver Tamper is supervised Memory when power is cut Digital voice module rv2006v 1 piece of voice message, time lasts 20s Follow-me number is assignable Timing function Auto daily arm Auto daily test report Disarm/arm report at window Monitoring function Trouble data can be displayed on keypad, and also can be transmited to central station Spare battery in low power Expansion module of power suplly battery in low power Siren circuit in trouble Power expansion module of siren circuit in trouble
Lcd keypads (rp248kcl) Display of two lines and 32 characters 3 keypad emergency zones: panic[1]+[2], fire[4]+[5], special emergency[7]+[8] Menu indicates the user functions and the installer programing Key-press with audible feedback System condition display Trouble display Led indication: alarm, power, armed, disarmed, bypass, ready, tamper User information is displayed on screen (except for password) Lcd backlight Tamper is supervised Alarm by duress code Easy to use hot-keys for simple bypassing and not-ready zones display One button for quick arming One button for quick perimeter arming Alarm memory display System trouble display Up to 4 lcd keypads can be connected Mainboard¡]rp248mb¡^ Zone terminal resistor (2.2k£[) 8 zones on mainboard Expandable up to 72 programmable zones Special zones: zone-5 is fire zone, zone-6 is tamper zone Can be parted to 8 divisions 11 types of programmable zones, 7 types of voice formats Zone terminal: nc, no, single end with resistor Programmable output: 70ma Expandable to 32 large current output: 3a 50 event records 8 groups of 4 gradable codes Switch output: 250ma Built-in siren driver: 750ma max Built-in digital clock Daily test report Function of end calling Disarm/arm report 4 lcd keypads can be connected to control panel Programmble voice for the siren output Current output¡g750ma(max) Auxiliary power output: 400ma Mainboard has 7 types of fire alarm bell voice drivers Connectible with four 1.5v 12a power supply expansion boards Mainboard has one 70ma programmable open circuit collector Connectible with 32 c-type programmble relays of 3a Circuit responding time of each zone can be set as 10ms, 500ms or 1s The distance is up to 1500m between module and control panel Built-in digital communicator Attached digital communicator, compatible with contract id¡a4+2 2 central station numbers 4 follow-me phone numbers
Ambient humidity: 60-90% Noise level: less than 60db Counting speed: more than 1000pcs/min Power source: 220v+_10% 50hz or 110v+_10% 60hz Power consumption: less than 40w Counting display range: 1-999 Batch display range:1-100 Hopper capacity: 200pcs(new bill) Stacker capacity: 200pcs(new bill) Banknote size: 110-180mm long, 50-85mm wide, 0.075-015mm thick Dimension:250x240x170mm Net weight : 7kgs/pc Package: each with gift box, 2pcs/ctn, 17.6kgs/ctn, 0.07cbm/ctn
Metal Detector
Pir motion detector High performance passive infrared motion detector, compact size and streamlined design is ideal for the security application. Auto pulse signal processing, 2 levels adjustable Auto temperature compensation 2nd generation fresnel lens Optional other lenses High density smd design Additional connector for eol resistor Fire resistant case Net weight/shipping weight 80g/115g Size 66f-93f-52mm (wxhxd)
Features Mcuprocessing Petimmunity Whitelightfilter Autotemperaturecompensation, reducingfalsealarm Ledon&offoptional Alarmdurationadjustable Adoptedsmt, highemi/rfiimmunity Technicalspecification Operatingvoltage:dc9-16v Supplycurrent:f_20madc12v Workingtemperature·ª-10f¦to+50f¦ Installationmethod:wallmounted Installationheight:about2.2m Detectingangle:110fp Detectingdistance:12m Petimmunity: