Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter 1. Temperature: 2. Relative humidity 3. Rated Primary Current:5-5000A 5A,1A 4.Rated secondary current:5 1A 5 Accuracy Class 0.05S 6. Allow long-term work under the rated current; More than120A across the core. Precautions: 1. The current of standard CT and tested CT must be the same in CT calibration. 2. Follow the given wiring diagram strictly. 3. Test whether the load box is accurate or not before calibrating the transformer. 4. Forbid secondary winding opening during the calibration. 5. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. 6.Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Used in current transformer & power transformer, also used in servo voltage stabilizer & variable auto transformer - dimmer or variac. As per customer requirement.
Product description Transformer Standard current transformer are also called precision current transformers, current transformer standards, standard CT and current transformer standards. Transformer standards are divided into current transformer standards and voltage transformer standards. Standard current transformers are used in the error test of transformers. Used as a current transformer calibration standard technical parameter Temperature -5 40 Relative humidity 80% Rated Primary Current 5-5000A 5A,1A Rated secondary current 5A 1A Accuracy Class 0.05S Allow long-term work under the rated current; More than120A across the core. Precautions The current of standard CT and tested CT must be the same in CT calibration. Follow the given wiring diagram strictly. Test whether the load box is accurate or not before calibrating the transformer. Forbid secondary winding opening during the calibration. Select demagnetization before calibration.The wiring diagram is shown in figure 5. Short out the secondary winding before cutting off the power when the demagnetization is finished. Principle wiring diagram of CT with large current generator is similar to above diagram. They are the same except the output winding of large current generator and primary winding of transformer are the same one.
Product description Current transformer field tester was developed with high-end testing technology, large-scale electronic circuit design and accord with national related protocol . It has solved the problem of big working intensity,trival operation while on-site test of current transformer, voltage transformer. Meanwhile the product has a reliable performance,and the function is strong. Technical index
• Rated current: 5 or 50A • High accuracy • Customized specifications are accepted. Carton.
Supplier: Current Transformers, Potential Transformer,
Buyer: Crgo Core , Insulating Paper, Copper Wire
Copper Flexible /Rope, Terminal Connector
Bushing , (ht Insulator), Tank, Rubber Ring And Rubber Gas Kit And
Transformer Oil
• EC, EE.EI and PQ type high frequency switch transformer • EP type magnet shielding switch transformer • RM type communication filter, aux power transformer • ET, FT type linearity filter • T (ring) type filter and switch transformer • G (jar shape) switch transformer • DR (I) type transformer • T (ring) iron power core, DC filter inductor • Application: switching power supplies, chargers, alarm system, TV and CRT monitor displays, UPS, VCD/DVD players, audio and visual equipment, OA machines and inverter • Used in high-density installation with nice shielding • Also can supply: Switching power transformer Pulse transformer Telecom transformer Audio frequency transformer Isolated and line matching transformer Ignition transformer EE5 current sensor transformer ADSL transformer EFD series transformer ER series transformer RM series transformer EP series transformer EPC series transformer EE series transformer • Available in various types of transformers (PQ,CI, UI, EFD, EP, ER, EPC, POT, RM and EE) • Suitable for EL/CCFL inverter or DC/DC converter • Customized designs are accepted. Carton.
Supplier: Transformers like current transformers, toroidal transformer
Product Introduction Capacitive voltage transformer (CVT) in calibration the test must be conducted under the condition of 50Hz frequency complex geographical condition on site at the same time the traditional experiment device is difficult to meet the requirements of on-site handling testing series resonance booster device is first used in domestic field tunable resonance device has been widely used in domestic 500 kv and below the field calibration of capacitor voltage transformer. Product Parameters Technical parameters Rated Capacity 80kVA rated voltage 160kV Adjustable inductance range 65~130H Rated frequency 50Hz Rated current 0.5A Adjustable gap range 0~300mm