Siemens, merlin gerin, abb, westinghouse, honeywell, ge, schneider, allen bradley, moeller, aeg, fuji, furnas, albright, lovato, benshaw, hager, l&t, brook, chint, danfoss, omron, teco, sprecher, stromberg, togami, joslyn clark, eaton, matsushita. Specific contactors, low voltage contactor, magnetic contactors, solid-state contactor, definite purpose contactors, modular contactor, low noise contactor, miniature contactor, standard contactor, contactors for special applications
Power Contactor Range Rating: 9A~200A Poles: 3Pole & 4Pole Available Brands : Scheneider, Siemens, ABB, Larsen & Toubro, Eaton, C&S, Legrand, Havells, BCH
GSC1 series AC Contactors are used in the circuit of 50Hz or 60Hz frequency with rated current up to 95A under usage category AC-3 at 380V AC. These AC contactors comply with IEC60947-4: Rated Isolation Voltage: up to AC690V Rated Voltage: 220V AC or 380V AC or 415V AC or 440V AC or 660V AC Rated Current under usage category AC-3 at 380V AC (A) : 9A, 12A, 18A, 25A, 32A, 38A, 40A, 50A, 65A, 80A, 95A Rated Thermal Current (A): 25, 25, 32, 40, 50, 50, 60, 80, 80, 125, 125 Controlled Load Power at 380V AC (KW): 4, 5.5, 7.5, 11, 15, 18.5, 18.5, 22, 30, 37, 45 Electrical Life (104) under usage category AC-3: from 60 to 100 Operation Frequency under usage category AC-3 (times per hour): from 300 to 1000 Mechanical Life (104): from 600 to 1000 Contact number: 3P+NO or 3P+NC, 3P+NO+NC if Rated current being over 38A. Frequency: 50Hz or 60Hz Coil Voltage: AC24V or AC48V or AC110V or AC220V or AC380V. Contact: 90% Silver and 10% Ni or 88% Sliver and 12% Cadmium Oxide.
Overview The AF Series 1-stack 3-pole contactors are of the block type design. Main poles and auxiliary contact blocks: 3 main poles, 1 built-in auxiliary contact, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC or DC operated - Accessories: a wide range of accessories is available UA16-30-10 RA UA26-30-10 AF9-30-10 AF1250-30-11 UA16-30-10 RA UA26-30-10 AF12-30-10 AF1350-30-11 UA16-30-10 RA UA26-30-10 AF16-30-10 AF1650-30-11 UA16-30-10 RA UA26-30-10 AF26-30-11 AF2050-30-11 UA26-30-10 RA UA30-30-10 AF30-30-11 AF2650-30-11 UA26-30-10 RA UA30-30-10 AF40-30-11 A9-30-11 UA26-30-10 RA UA30-30-10 AF50-30-11 A12-30-11 UA26-30-10 RA UA30-30-10 AF63-30-11 A16-30-11 UA30-30-10 RA UA50-30-00 AF75-30-11 A26-30-11 UA30-30-10 RA UA50-30-00 AF95-30-11 A30-30-11 UA30-30-10 RA UA50-30-00 AF110-30-11 A40-30-11 UA30-30-10 RA UA50-30-00 AF116-30-11 A50-30-11 UA50-30-00 RA UA63-30-00 AF140-30-11 A63-30-11 UA50-30-00 RA UA63-30-00 AF145-30-11 A75-30-11 UA50-30-00 RA UA63-30-00 AF146-30-11 A95-30-11 UA50-30-00 RA UA63-30-00 AF185-30-11 A110-30-11 UA63-30-00 RA UA75-30-00 AF205-30-11 A145-30-11 UA63-30-00 RA UA75-30-00 AF210-30-11 A185-30-11 UA63-30-00 RA UA75-30-00 AF260-30-11 A210-30-11 UA63-30-00 RA UA75-30-00 AF265-30-11 A260-30-11 UA75-30-00 RA UA95-30-11 AF300-30-11 A300-30-11 UA75-30-00 RA UA95-30-11 AF305-30-11 A320-30-11 UA75-30-00 RA UA95-30-11 AF370-30-11 AF460-30-11 UA75-30-00 RA UA95-30-11 AF400-30-11 AF580-30-11 UA110-30-11 UA110-30-11 UA110-30-11 AF750-30-11 UA110-30-11 UA110-30-11 UA110-30-11
1.Introduction JCZ5 7.2 kv vacuum contactor HVJ6-7.2 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 7.2KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of F-C circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 7.2 kv Control voltage: 110V, 220V Rated current: 200A, 400A, 630A Contacts separation: 4.5+1-0.5mm Over travel: 1.5±0.5 mm Main circuit power frequency voltage withstand: 32000 V Auxiliary circuit power frequency withstand voltage: 2500 V Control circuit power frequency withstand voltage: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 28KG
1.Introduction JCZ5 12kv vacuum contactor HVJ6-12 series indoor high-voltage AC vacuum contactor has two types: One is Mechanical holding type, the other is Electromagnetic holding type. It is applicable for three-phase AC 50HZ power system of rated voltage 12KV and below and rated current up to 630 A to open and close circuit remotely and control electrical equipment like high-voltage motor, transformer and capacitive load. It is especially suitable for fields operated frequently. The contactor uses the international fashionable up and down structure arrangement and has the advantages of small, light, easy to maintain and form a complete set of circuit equipment. 2. Service condition a) Ambient air temperature: -25- +40. b) Altitude not exceed 2000m c)Humidity: -Relative humidity: daily mean not higher than 95,monthly mean not higher than 90; -Aqueous vapor pressure: daily mean not exceed 2.2 KP, monthly mean not exceed 1.8 KP Ambient air should not be obviously polluted by corrosive or flammable gas or vapor; C)Free of frequent severe vibration; When running, angle of inclination between installation surface and horizontal plane should not exceed 5. Main technical parameters Rated voltage: 12000 v Control circuit: 110V 220V Rated current: 200A 400A 630A Contacts separation: 5+1-0.5 mm Over travel: 1.5±0.5 mm Main circuit power frequency withstand voltage: 42000 v Auxiliary circuit power frequency voltage withstand: 2500 v Control circuit power frequency voltage withstand: 2000 V Making capacity: 10le,100 times Breaking capacity: 8le, 25 times Limit breaking current(A): 10le Mechanical life times: 30104 Weight: 32KG
We supply all the types of AC Contactors as per the desired applications and also maintain the international quality standards
We supply all the types of DC Contactors as per the desired applications and also maintain the international quality standards
Part NO Coil Voltage 50/60HzNumber of PolesFull Load (A)Maximum Voltage 25 FLA -2 Pole QCA-25224225120 QCB-252120240 QCC-252208/240 30 FLA-2 Pole QCA-30224230120 QCB-302120240 QCC-302208/240 40 FLA-2 Pole QCA-40224240120 QCB-402120240 QCC-402208/240
Series ac contactor is suitable for using in the circuits up to the rated voltage 660v ac 50hz, rated current up to 95a, for making, breaking, frequently starting & controlling the ac motor. Combined with the auxiliary contact block, timer delay & machine-interlocking device etc, it becomes the delay conactor, mechanical interlocking contactor, star-delta starter. With the thermal relay, it is combined into the electromagnetic starter. The contactor is produced according to iec947-2, vde0660 & bd5452.