Intravenous Infusion System (With Multiple Stopcocks In line) Product Code: MED 180 Specifications: Sterile, individually packed in Medical Grade Blister Pack Description Polycarbonate body and polyethylene lever. Easy to operate and smooth to turn. Large internal lumen. Highly resistant to pressure and chemicals over a wide range.
Infusion pump Specifications Controls: Drop counting and adjusting the delivery rate automatically Pump type: peristaltic finger Applicable iv sets: Various iv sets(including lucifugal iv sets) Accuracy: 25drop/min:2%, >25drop/min:3% (used in the drop counting control way) 5% (used in the volumetric control way with the correct calibration) Delivery rate range: 1½400drop/min(1drop/min step) 1.0ml/h½1200ml/h (1.0ml/h½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) Delivery time range: 1min½1999min (1 min step) Volume limit range: 0½9999ml (1 ml step) Total volume range: 1½9999ml (1 ml step) Purge rate: 600ml/h Kvo rate: When the delivery rate 10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h. Alarms: Air-in-line, infusion complete(a volume limit has been set), empty container, occlusion, door open, over time, no drop sensor, operation error, low battery and other device failures. Power source: Ac power supply: ac 100 to 240v10%ú¼50/60hzú+ Internal li battery: 11.5v, 2000mah. Battery life with continuous operation is approx. 8 hours (when using a new, full charged battery and running at 20drop/min with any standard of iv set). Power consumption: 25va Shock protection: classó, type bf Dimensions: 130mm 200mm 230mm
Automatic calibration Audible and visible alarms Three working mode: rate/time/volume With ultrasonic sensor for drop-counting Lcd, night operable English or other language display Specifications Drop detector: outside caliper rotary detector. (patented technology) Control way: Drop counting and adjusting the delivery rate automatically Pump type: peristaltic finger Applicable iv sets: Compatible with iv sets of any standard (including lucifugal iv sets) Accuracy: ín25drop/min: ía2%, >25drop/min: ía3% (with the drop counting control mode) ía5% (with the rate control mode after the correct calibration) Delivery rate range: 1í½400drop/min(1drop/min step) 1.0ml/hí½1200ml/h (1.0ml/hí½99.9ml/h, 0.1ml/h step; >99.9ml/h, 1ml/h step) Delivery time range: 1miní½1999min (1 min step) Volume limit range: 0í½9999ml (1 ml step) Total volume range: 1í½9999ml (1 ml step) Rapid injection: 600ml/h Bolus: bolus rate 10-1200ml/hr, bolus volume: max of 100ml Kvo rate: When the delivery rate ín10ml/h, kvo is 1ml/h. Otherwise kvo is 3ml/h. Alarms: Air-in-line, infusion complete when limited volume has been set, empty container, occlusion, door is open, waiting time over, no drop been detected, operational errors, low battery, other device failures. Power supply: Ac power supply: ac 100 to 240vía10%ú¼50/60hzú+ Internal li battery: 11.1v, 2000mah. 6 hours of continuous operation on a new fully charged battery with the rate of 20 drops/min. Power consumption: ín25va Safety level: classó±, type cf Operating conditions: ambient temperature: 5 to 40íµíírelative humidity: 20 to 90% Storage conditions: ambient temperature: -10 to 55íµíírelative humidity: 10 to 90% Accessories: ac power line, operational manual Dimensions: 130mm(l)íß 200mm(w) íß 230mm(h) Net weight: approximately. 2.0kg
Infusion Blood Transfusion Sets Blood Donor Sets Disposable Syringe Insuline Syringe IV Cannula Safety IV Cannula IV Cannula Fixator Scalp Vein Set Measured Volume Burette Set Extension Tube IV Flow Regulator Three Way Stopcock Three Way Stopcock With Extension Tube Pressure Monitoring Line Luen Lock Injection Stopper CVP Manometer
Supplier: Cannula, needles, syringes, infusion sets, extension line, and other disposable device
IV Dressing Product Code: Box of 50; Carton of 1000. Size/Strength: Box of 50; Carton of 1000. Description IV Dressing that consists of micro porous non-woven fabric (Polyethylene film), medical hypo-allergenic adhesive and absorbent pads. These are mainly used to fix vein bleeding and all kinds of cannulae and infusion lines. Made form high quality woven cloth with mesh these IV dressing and cannula fixation dressing make skin breathe properly and naturally, excreting water and air thus reducing the chances of infection. Total liberty of movements and improved conformance allowed due to gentle and thinner material for improved conformance. Reliable fixation enabled because of Hypoallergenic and proper viscidity characteristics and no viscosity of the absorbent pad with perforated polyethylene film, high absorbent, power, can absorb the effusion and it is power, can absorb the effusion and it is treated on the surface to avoid sticking on the wound. Monitoring allowed without the removal of the IV dressing or IV transparent dressing due to transparent film leading the insertion site under the center of dressing. The IV dressing is softly pressed around the insertion site and then the PE protective film from PU film layer is released. It is individually packed in peel pouches and is E.O gas sterilized.
Supplier: Disposable medical devices: syringes, needles, infusion sets, cannula, extension line, 3-way stopcock, protective cap
3 Way Stop Cock With Extension Line Product Code: MED 156 Specifications: Sterile, individually packed in peelable pouch pack Size/Strength: 25/50/100/200 cm Extension lengths Description Disposable, sterile and non-pyrogenic. Manufactured from non-toxic PVC. Minimizes movement at cannulation. Reduces chances of irritation and infection. Extends the pathway between the infusion site & the source of infusion Available with built-in 3-way stopcock Fitted with male luer lock at on end & three-way stopcock at the other
Safety Huber Needle Features and Benefits Sterile pack, single use only. Needle-stick prevention, safety assured. Special needle tip design to prevent rubber fragment contamination. Luer connector, equipped with needleless connector, heparin cap, Y three-way. Chassis sponge design for a more comfortable application. High pressure resistant central line with 325 P.S.I Two holes connector optional. MDR 2017/745 USA FDA 510K Refer Standards ISO 10555-6:2015 Intravascular catheters - Sterile and single-use catheters Part 6: Subcutaneous implanted ports. ISO 8536-4: 2010 Infusion equipment medical use- Part 4: Infusion Sets for single use, gravity feed. ISO 23908:2011 Sharps injury protection Requirements and test methods - Sharps protection features for single-use hypodermic needles, introducers for catheters and needles used for blood Samplings. ISO 7864:2016 Sterile Hypodemic Needles for Single-use requirements and test methods. ISO 9626:2016 Stainless Steel Needle Tubing for the Manufacture of Medical Devices requirements and Test methods. ISO 80369-7: 2016 Small - bore connectors for liquids and gases in healthcare applications. Part 7: Connectors for intravascular or hypodermic applications. ISO 10993-7:2008 Biological Evaluation of Medical Device - Part 7: Ethylene Oxide Sterilization Residuals.