1. Monitor the real time connection and disconnection of ESD table mat to ground 2. Monitor the real time connection and disconnection of wrist strap to ground, under the guaranteeof double to ground, the path integrity of ESD to ground is more ensured 3. Monitor has the anti-stupidity function, red LED will flash and comes with audible alarm after power monitor on, plug wrist strap and connect proper ground, green LED will illuminate 4. Plug wrist strap into monitor socket, monitor will alarm when wear wrist strap abnormally 5. Monitor will alarm when wrist strap is in open circuit or poor contact 6. Monitor 2 single wrist straps and 1 table mat simultaneously 7. Accuracy 8. When monitor alarm, red LED light flashes and also comes with buzzer sounds 9. Suitable for any kind of single wrist strap 10. Beautiful appearance, strong anti-interference ability
1. Built-in static electricity elimination device, it can blow the particulate pollutant when eliminiate the static electricty. 2. ABS plastic casing, ergonomic handle, lightweight design to improve efficiency. 3. Automatic ion balance system, decay time less than 1 second, ion balance less than 15 V ( The distance is 15CM, the pressure 0.5 Mpa ) 4. Built-in miniature transformer, no need of external high voltage wiring safety design, no electromagnetic interference, no danger of electric shock. 5. The emitter needle can be replaced, and it can prolong the using life of the whole machine, optional throttle valve, control air flow. 6. A variety of connectors can be selected to meet the requirements of a variety of occasions. 7. It meets the safety standard requirements of CE FCC.
1. The grounding system is the most common and effective way to ensure the ESD safety of a process. Equipment Ground Monitor 001-9035SC is a comprehendive real time groud monitor that check the connection of equipment to grounds. It provides independent ground monitoring of up to four tools. It solved the problem of the damage which caused by the ground wire corroded, loose etc. And also saved the time and labor costs for regular inspections of ground connection. 2. Equipment Ground Monitor can continuously monitor the grounding status of equipment, ESD grounding system and resistance of equipment casing. 3. It provides independent ground monitoring of up to four tools. 4. 24 hours real-time monitor 5. Audible Alarm will enable when the resistance is over the limited resistance, and the audible alarm also could be disabled. 6. Specific limits of resistance can be set according to customer requirements to accurately control the grounding system. If no requirements are specified, default ground impedance is set at the factory. 7. The monitoring resistance group can be set in the range of 0 - 25 , accuracy 1% 8. Optional monitoring software platform to realize remote monitoring and data processing. 9. Wireless transmission or RS485 communication mode, suitable for different working conditions. 10. With alarm indicator, which can add external red and green LED alarm indicator. 11. Built-in LCD display which can display the resistance of setting value, testing value and monitoring status.
1. Monitor the real time connection and disconnection of ESD table mat to ground. 2. Monitor the real time connection and disconnection of wrist strap to ground, under the guarantee of double to ground, the path integrity of ESD to ground is more ensured. 3. Monitor has the fool-proofing function, red LED will flash and comes with audible alarm after power monitor on, plug wrist strap and connect proper ground, green LED will illuminate. 4. Plug wrist strap into monitor socket, monitor will alarm when wear wrist strap abnormally 5. Monitor will alarm when wrist strap is in open circuit or poor contact 6. Monitor 1 single wrist strap and 1 table mat simultaneously 7. Accuracy: + / - 10% 8. When monitor alarm, red LED light flashes and also comes with buzzer sounds 9. Suitable for any kind of single wrist strap 10. Beautiful appearance, strong anti-interference ability
1. Real time monitor single wrist strap grounding function 2. Monitor has OFF function, dial switch to ON, red light illuminate and monitor will turn green while connect wrist strap 3. Plug wrist strap into monitor socket, monitor will alarm when wear wrist strap abnormally 4. Monitor will alarm when wrist strap is in open circuit or poor contact. 5. Monitor will alarm when grounding cord is in open circuit accidentally 6. Monitor 1 single wrist strap and itself grounding cord 7. Wrist strap alarm limit: 1.2 M ( factory preset ) 8. Accuracy: 10% 9. When monitor alarm, red LED light flashes and also comes with buzzer sounds. 10. Suitable for any kind of single wrist strap 11. Beautiful appearance, strong anti-interference ability
001-0385 surface resistivity meter is designed according to ANSI / ESD S20.20, IEC61340-5-1, JESD 625-B, CECC AST & UL test rules. It is used to measure all conductive, anti-static and dissipative material s resistivity and ground resistance. This meter uses ASTM D-257 parallel bar induction method, and automatically calibrates the range through high speed op-amp. It is easy to use and has high reliability. Applications include engineering, maintenance, quality control, incoming inspection, manufacturing and training.
1. 001-9802 surface resistance / resistivity meter is designed according to ANSI / ESD S20.20, IEC61340-5-1, JESD 625-B, CECC, ASTM & UL test rules. It is used to measure all conductive, anti-static and dissipative material s resistivity and ground resistance. It is easy to use and has high reliability. Applications include engineering, maintenance, quality control, incoming inspection, manufacturing and training. 2. Measuring resistance: 10e3 -10e12 3. Surface resistivity: 10e3 -10e12 4. Measuring temperature range: 32 F-100nF ( 0C-37.8 C ) 5. Measuring humidity range: 10% -90% RH ( above 65% RH will affect the instrument measuring accuracy ) 6. Display mode: LCD display 7. Two-stage test voltage: 10V ( the measured resistance is less than 10e6 ) / 100V ( the measured resistance is 10e6 ) 8. AC adapter: input voltage -120V/AC or 220V/AC, output voltage -9V/DC 9. Power supply: DC or battery power supply, both are common used in US and overseas countries ( Note: External power supply and battery power supply cannot be used at the same time ) 10. 2.27 kg0.06 kg ( 5 lbs 2 ounces ) cylindrical electrodes with two conductive contact surfaces with a diameter of 63.5 mm 25 mm ( 2.5 inches 1 inches ). 11. The Shore A ( IRHD) hardness of the conductive material of each electrode is between 50 and 70 12. Dimension: 191mmx102mmx39mm 13. Automatic power-off function to extend battery using life. 14. The function of automatic return to zero which is convenient for continuous and quick testing.
1. Testing the system resistance of single / dual wire wrist strap and ESD footwear. 2. With LCD / LED display and alarm. 3. Testing resistance can be displayed on LCD screen. 4. Testing range: 10K-100M. 5. Dual footplate, can individually test two shoes simultaneously. 6. Finish the test of wrist strap and ESD shoes in 2 seconds. 7. Touch testing button could be used long time, no worries on the testing button fault. 8. Installation could be wall mounted and fixed table installation. 9. Switching signal can be workable to realize tripod turnstile and electromagnetic lock linking under the situation of testing OK. 10. Testing voltage is 28VDC, the maximum current is 0.0025mA, at the time of improving test accuracy and guarantee operator s safety.
1. Testing the system resistance of single / dual wire wrist strap and ESD footwear. 2. With LCD / LED display and alarm. 3. Testing resistance can be displayed on LCD screen. 4. Testing range: 10K-100M. 5. Dual footplate, can individually test two shoes simultaneously. 6. Finish the test of wrist strap and ESD shoes in 2 seconds. 7. Touch testing button could be used long time, no worries on the testing button fault. 8. Installation could be wall mounted and fixed table installation. 9. Switching signal can be workable to realize tripod turnstile and electromagnetic lock linking under the situation of testing OK. 10. Testing voltage is 28VDC,the maximum current is 0.0025mA, at the time of improving test accuracy and guarantee operator s safety.
1. Rapid neutralization of static charges 2. Large coverage of ion airflow 3. Wide range of airflow speed regulation 4. Dedicated cleaner for ion generating electrode 5. Ionization indicator 6. Special design on cold air & heater 7. Reliable grounding protection