Non-Sterile Medical Examination Nitrile Gloves Powder free & Latex free 100% Virgin raw materials with FDA certificate & as per ASTM D6319/ CE EN 455 Quality standard: ASTM D6319, with 510K and FDA, CE/EN455, Color: Blue, white Finger Tips: textured Cuff: Beaded Pcs per Box for S/M/L/XL : 100pcs/box Origin: China, Vietnam, Thailand, Malaysia Benefits Protection from unwanted and harmful substances Beaded Cuff ensures easy donning and prevent roll down Superior Strength with better Puncture resistance Finger Tip Textured enhances wet and dry grip Thinner Guage improves tactile senstivity Custom Design enhances comfort and fit Provide an Alternate Solution for individual who are allergic to natural rubber latex Material : Synthetic Nitrile Type : Non-Sterile Powder Free, Amibidextrous, Finger Tip Textured, beaded cuff. Storage: Store in a dry and cool place, the temperature not higher than 38�° C Shelf life: 2 years Physical Properties Tensile Strength: Before Aging 14Mpa min Tensile Strength: After Aging 14Mpa min Elongation at Break (%): Before aging 500% min Elongation at Break (%): After aging 400% min Length: 230 mm in XS, S, M, L, XL Width: 70+/- 10 (XS) Width: 80+/- 10 (S) Width: 95+/- 10 (M) Width: 110+/- 10 (L) Width: 120+/- 10 (XL) Thickness Single wall ( mm): Fingers 0.050mm min Thickness Single wall ( mm): Palm 0.050mm min
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
Features in Steam Sterilization •Drgonomic design for easy operation •High quality components •Fully automatic operation •Microprocessor based controller •Built in digital adjustable timer with memory programs •Mechanical controlled door •Safe to use Safety Standard for Steam Sterilization •Pressure switch for additional safety. •Cycle will not start unless door is closed completely. •Safety high pressure release valve. •Door will not open while chamber is pressureized. •Low water indication when reservoir is empty. •Door open indication when door is not closed. •Mechanical controlled door to prevent door from opening during pressurized process. Overall Dimensions: 560(W) x 580(D) x 400(H) mm Chamber Dimension: Chamber Capacity: 16L:260x288mm;20L:260x360;24L: 260x432mm Power Consumption: 230Vac 2000W / 230Vac 1852W Sterilization Temperautre Pressure: 121°Cto 20-60mins; 134°Cto 4-60mins Dry Time: 0-60mins Standard Accessories: Sterilizing Cassette x1 Weight: 50kgs.
Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
* Fully stainless steel structure * Hand wheel type of quick open door structure * Door safety lock system * Automatically controlled by computer * Digital display of working status, touch type key * Over temperature & over pressure auto protection * Steam water inner circulation system, no steam discharge and the environment for sterilizing will be clean and dry * Self inflating type seal * Safe protection of water lacking * The drying system is optional, which can be equipped according to the customer's request * Automatically shut iff with beep reminding after sterilization * With two stainless steel sterilizing baskets.
Feature Intelligent microcomputer control system: -Using LED digital control system; -After sterilization finished, sterilizer will automatically alarm and shut down. Interlock device: -The control system can real time supervision the sterilizer chamber's temperature and pressure. -Only under the safe-ty temperature and pressure can open the sterilizer's cover. Make sure the operator's safety. The structure of cover's opening: -Using shift place type of quick-open cover to improve sealing and safety performance. Preset program: -Can preset fixed program that sterilize solid body. Memory storage system: -Store the last operation program so convenient next operation. Digital display screen: -Digital display screen and working indicator light display running state. Safety devices: -Interlock device, overtemperature and over pressure protecting system. -Burned protection, safety relief valve, current leakage protector and automatic fault detection.
Supplier: Woven/knit and non woven fabric and its relative products like disposable medical products, home/hotel textiles, essential oils, household appliances, kitchenware, fiberglass mesh cloth, etc.
Supplier: Electrical materials, electrical equipments, lighting fixtures, plumbing materials, ac materials, it materials, ceiling materials, partition materials, painting materials, floor tiles, hardware materials, hand tools & power tools, garage tools, wooden & carpenter materials, batteries. medical equipment and medical consumable product and medical surgical equipment.
Disposable Syringes 3ml 3Part Hypodermic Syringe Sterile , with Needle Size : 23 G x 1 It is suitable for subcutaneous, intradermal, intramuscular, intravenous injection or drainage. Material-medical grade PP Color-transparent Certificate -CE, ISO Specification -1ml, 2ml, 3ml, 5ml, 10ml, 20ml, 30ml, 50ml