AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
Supplier: Heavy machinery, tools, metal products, screws, antenna, cable, exercise bike, relay, GPS, tool and die, connector, mold, mould, wire, plastic film, light, wiring harness, pump, precision part, switch, power supply, engine, terminal, inverter, converter, casting, machining, inductor, transformer, motor, plastic sheet, plug
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG018SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG018SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Tap Std Burden / D.M.T 3 VA / 3 Secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set/High set contact CAG 13 / 2 N/O S/R Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
GBCDG61EG046SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no - CDG61EG046SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting O/C- 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary - 5 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 1 to 4 amps High set - O/C Setting- 25 to 100 amps High set - E/F Setting- 10 to 40 amps High set - CAG 13 Name plate - RFG9126 904 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG042SHCH IDMT 2 O/C & 1 E/F RELAY WITH HIGH SET Technical specification Relay model no- CDG61EG042SHCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 2M2B H/R 2M S/R Output contacts - 2M2B H/R 2M S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden - 3 VA Operating time - 3 secs Current setting - E/F - 0.2 to 0.8 amps High set - O/C Setting- 4 to 16 amps High set - E/F Setting - 1 to 4 amps High set - CAG 13 Name plate - RFG9126 902 Outline drawing - MFJ 014 Wiring diagram - MADZ 821.29-1
GBCDG61EG054SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG054SGCH Relay type - CDG 61 Case size - 3D H 30T Application - 2 O/C & 1 E/F Current setting - O/C - 0.5 to 2 amps Contacts - 3 N/O S/R Output contacts - 2 N/O S/R C.T.Secondary - 1 amps Frequency - 50 Hz Burden / Operating time - 3 VA / 1.3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 2 to 8 amps High set CAG 13 Name plate RFG9125 902 Outline drawing MFJ 014 Wiring diagram - MADZ 821.27-1
GBCDG61EG057SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no - CDG61EG057SGCH Relay type - CDG 61 Case size - 3D HOR. Application - 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Burden / Operating time 3 VA / 3 secs Current setting - E/F 0.2 to 0.8 amps High set - O/C setting 4 to 16 amps High set - E/F setting 1 to 4 amps High set CAG 13 Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1