DESCRIPTIOn: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT: 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY : Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND counter Balance Mobile
DESCRIPTION: Titanx RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Floor to Ceiling Column Stand
DESCRIPTION: Titanx100 RADIOGRAPHY RATING: 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT : 8KW RECTIFICATION: Full Wave Rectified TIMER: 0.06 to 5 sec DIGITAL DISPLAY: Digital Display of mAs, kV & mA X-RAY TUBE: XD-3/Imported POWER SUPPLY: 230 Voltage AC, 15 Amps LINE REGULATION: 10% 0.6max PROTECTION: Electronic overload Protection TUBE STAND: Counter Balance Mobile
DESCRIPTION- TITANX 100 RADIOGRAPHY RATING- 25-100mA, stations 45kVp to 100 kVp in 15 steps OUTPUT 8KW RECTIFICATION- Full Wave Rectified TIMER- 0.06 to 5 sec DIGITAL DISPLAY- Digital Display of mAs, kV & mA X-RAY TUBE- XD-3/Imported POWER SUPPLY- 230 Voltage AC, 15 Amps LINE REGULATION- 10% 0.6max PROTECTION- Electronic overload Protection TUBE STAND- Spring Balance
Type of Tube Stationary Anod X-ray Tube Focal Spot 1.4mm Rating 50mA at 85 KVP Inbuilt LED Collimator Safety Voltage Over Load Protection Input Power 220V-50/60Hz - AC, Single Phase Timer 0.06 to 8 second (24 steps) Indicates Main ON, Overload and x-ray ON Type Truly Portable Carry away box type Machine
Application:- X-Ray unit is used for radiographic work and useful for Chest, Cervical, Exteremities. Panel control and functional description :- SX-30mA Ray unit provides case of operation with simple feather touch as well manual control the use can adjust the required voltage rating just by selecting V/comp knob that can visible on Voltage display and set up to till overload and for proper setting keep one step behind the overload Voltage at 220 V by using Voltage Compensator.It is also used for Veterinary clinics. REAL PORTABLE X-RAY:- Truly Portable Carry away box type Machine Voltage Over Load Protection LED Collimator Micro Processor primarily based Digital with Accuracy of zero.01 Sec. Exposure Time is Set by soft button . Hand switch for exposure in single touch Weight 18Kg of 30mA and 19.5kg of 50mA TECHINICAL SPECIFICATION :- Type of Tube Stationary Anod X-ray Tube Focal Spot 1.2mm Rating 30mA at 85 KVP Inbuilt LED Collimator Safety Voltage Over Load Protection Input Power 220V-50/60Hz - AC, Single Phase Timer 0.06 to 8 second (24 steps) Indicates Main ON, Overload and x-ray ON
100 mA Mobile x-ray machine. very good image quality. built in stabilizer. works on 220v AC.
Medical x-ray mobil Tube T280 ;x-ray generator Class 100kvp/12AC/DC date of manufacture juin 1998