Mn/300/100 fire alarm control panel Overview The mn300 is a new type of analog fire alarm control panel which has 100 alarm control points (detectors and modules which are characterized by fully mixed coding, non-polarity and two buses). It complies with the provisions of both fire alarm control units (gb4717-2005) and automatic control system for fire protection (gb16806-2006). Features 1 the intelligent detectors and the intelligent modules have internal microprocessors to realize digital filtering and auto-compensation functions; the data collection is true and reliable; the mn300 control panel can carry out data processing based on fuzzy control theory and modern fire alarm theory to fundamentally avoid missing alarms and to reduce false alarms, so as to improve reliability. 2 the detectors have a sensitivity setup function and can adjust the alarm sensitivity according to the specific environment and their influences. 3 the detecting bus and the control bus share a two-wire structure and have non-polarity and fully mixed coding of the detectors and modules, and the intelligent detectors and the intelligent modules can be directly connected to them, which greatly simplifies the system wiring, engineering installation and circuit maintenance. 4 the system uses an ac-dc master-standby power supply system which will automatically change between the master and standby power supplies in the event of a power failure of either of the two power supplies to ensure uninterrupted operation of the system. 5 the mn300 can be connected to a special mini-printer to realize real-time printing. 6 the mn300 can be connected to floor fire display panels to display fire alarms by standard rs-485 7 the mn300 can be connected to ten multi-line linkage control/monitoring points to control and monitor important equipment. 8 the mn300 is equipped with eight bus manual control points, which makes it very easy for the user to control related equipment.
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be connected To non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile Cause-and-effect pc-based programming tool enables rapid customization with software for sites that Require special operating features. The 6001 comes standard with features that allows flexibility and expandability. Single loop or 2-loop options available Single loop, expandable to 2-loops available Networkable, up to 4 control panels Up to 125 addressable devices per loop Automatic device detection on start-up Automatic device type-code verification 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output Backlit lcd display providing 4 rows of 40 characters 16 zone fire alarm led indicators 3000 event history log
1. General HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
Supplier: Conventional and addressable fire alarm systems
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
1. General HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems. 2. Specifications Name 6" Alarm Bell Item No. HS-JL188-6 Operating voltage DC24V Alarm current 70mA @ DC24V Alarm sound intensity Minimum 95dB Dimension Diameter 155mm, height 45mm Weight 650g Features Easy to install bracket 3. Features Operating Voltage : DC24V Alarm Current: Maximum 70 mA Alarm Sound Intensity: Minimum 95dB
The 6001 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm System. The fully networkable 2-wire 6001 is compatible with numens addressable devices and can also be Connected to non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile Cause-and-effect pc-based programming tool enables rapid customization with software for sites that require Special operating features. The 6001 comes standard with features that allows flexibility and expandability. Single loop or 2-loop options available Single loop, expandable to 2-loops available Networkable, up to 4 control panels Up to 125 addressable devices per loop Automatic device detection on start-up Automatic device type-code verification 2 independently programmable non-addressable a/v alarm output circuits 2 programmable fire alarm relay outputs Fault relay output Backlit lcd display providing 4 rows of 40 characters 16 zone fire alarm led indicators 3000 event history log
The 660 manual call points includes a pressure-activated displacement element to provide a safe and convenient Way for building occupants to manually initiate a fire alarm condition. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the Operating face to the quiescent position. Pressure activated displacement element provides a safe user experience Integral indicator to show polling and alarm activation Resettable with simple key operation Suitable for indoor use Monitors for quiescent, alarm and fault conditions Dip switch address setting 125 usable detector address settings per loop
Conventional fire fighting control panel with 4 zones and 3 sound output, designed to connect with 2/4 wired smoke detector, heat detector, manual call point, manual release, gas release lamp etc. 1. Specifications a. Four Style B (Class B) Initiating Device Circuits (IDCs). b. All zones accept two-wire smoke detectors and any normally-open contact devices. c. One built-in Fire Fighting Ouput. d. 24-volt operation. e. Resettable four-wire smoke detector power @ 500 mA. f. Non-resettable power @ 500 mA. g. One-man walk-test programmable for silent or audible test. h. Disable/Enable control per IDC. i. Reverse polarity protection.