To determine the stability of electric appliances which are used on a table or on the floor In accordance with iec 60065 / 1998-07 clause 19.1, iec 60335-1 / 1991-04 clause 20.1, iec 60601-1 /1988 clause 24.1, iec 60950 / 1991 + amendments, modified, clause 4.1.1, en 60335-1 / 1994 and a11 / 1995 clause 20.1, en 60950 / 1992 + amendments up to 1997 clause 4.1.1, vde 0700 part 1 / 10.95 clause 20.1 and part 3 / 3.96 clause 20.1, vde 0730 part 1 / 3.72 clause 20a, vde 0805 / 11.97 clause 4.1.1 Packed with strong wooden case
Overview: The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum). 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion: Both voltage and current
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Optional accessories Cable port: two size of cable port is available: diameter: 50mm, diameter:100mm. Double door Pass room: provided to avoid disturbance of atmospheric temperature and humidity while opening the door. Floor reinforcement: can be fixed if heavy specimen placed in the chamber for test. Carry-in inclined platform: provided below the door to facilitate moving of specimens in and out through the door. normal running, a malfunction running or stand by occurs. Water purifier
Description Te261 visual fault locator is visible red laser source for finding breaks and tight bends in optical fibers. Te261 generates red laser and the visible red laser that escaping from optical fibers makes testing and finding breaks in lans, verifying continuity, checking the validity of patch cables or looking for cracked fiber in splice cases, bad connectors, and tight bends in fiber cable. Paper carton, 0.5kg
Overview: The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The single phase energy meter test instrument comprises of PWM power source, standard digital energy meter,error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05. 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05). Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum) 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion:Both voltage and current
Overview: The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion: Both voltage and current
1.Starting test and creeping test 2.Measuring the different constant meters synchronously. 3.With the protect function of overload, short voltage circuit and open current circuit. 4.The testing software with friendly windows 2000 and xp interface, include functional module of all kinds of modern energy meter needed, to reality error test, harmonic test, demand test, influence test. 5.The stored testing data can be transferred to multi-format for other program using
Snt 1100 single phase meter test bench is widely used in power utilities,¡émeter manufacturer,¡émeasurement/quality test lab and other enterprises to test single phase energy meter.
Measure normal parameter of power line: Vrms, irms, frequency Active power, reactive power, apparent power Phase angle between voltage and current Power factor Calibrate single phase meter; Measure harmonic of voltage and current; Measure waveform of voltage and current; Measure current transformer¡¡¥s ratio (option); Energy accumulation test; Built-in clock, record testing time exactly; Store, check and transmit the measured data; Connected to pc, reading recorded data and real-time measured data by pc; Alarm when the tested voltage and current over the testing range; Connected to portable printer (option).