To determine the stability of electric appliances which are used on a table or on the floor In accordance with iec 60065 / 1998-07 clause 19.1, iec 60335-1 / 1991-04 clause 20.1, iec 60601-1 /1988 clause 24.1, iec 60950 / 1991 + amendments, modified, clause 4.1.1, en 60335-1 / 1994 and a11 / 1995 clause 20.1, en 60950 / 1992 + amendments up to 1997 clause 4.1.1, vde 0700 part 1 / 10.95 clause 20.1 and part 3 / 3.96 clause 20.1, vde 0730 part 1 / 3.72 clause 20a, vde 0805 / 11.97 clause 4.1.1 Packed with strong wooden case
Overview: The RT6103B Multi-function single phase energy meter test instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function single phase energy meter test instrument comprises of PWM power source, standard digital energy meter, error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter(Accuracy class:0.1/0.05), Multi-path voltage transformer: Accuracy class:0.01;Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum). 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion: Both voltage and current
Overview: The RT6303-S Three Phase Energy Meter Test Instrument(Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The Three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis,digital frequency modulation,digital amplitude modulation,digital phase-shifting,pulse width modulation and so on to bring you such important features as high reliability and good load characteristics.Its more humane and intelligent meter calibration software makes it possible for an ordinary,heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter,Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range,adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion:Both voltage and current
Optional accessories Cable port: two size of cable port is available: diameter: 50mm, diameter:100mm. Double door Pass room: provided to avoid disturbance of atmospheric temperature and humidity while opening the door. Floor reinforcement: can be fixed if heavy specimen placed in the chamber for test. Carry-in inclined platform: provided below the door to facilitate moving of specimens in and out through the door. normal running, a malfunction running or stand by occurs. Water purifier
Description Te261 visual fault locator is visible red laser source for finding breaks and tight bends in optical fibers. Te261 generates red laser and the visible red laser that escaping from optical fibers makes testing and finding breaks in lans, verifying continuity, checking the validity of patch cables or looking for cracked fiber in splice cases, bad connectors, and tight bends in fiber cable. Paper carton, 0.5kg
Overview: The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The single phase energy meter test instrument comprises of PWM power source, standard digital energy meter,error processor and PC processing software, this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously, also is an ideal new-generation multi-position energy meter testing instrument. Technical Parameters: 1. Accuracy class: 0.1/0.05. 2. Reference standard energy meter£ºSingle phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05). Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA. 3. Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range. 4. Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum) 5. Phase angle:0~360¡ã,Resolution of phase angle setting:0.01¡ã. 6. Frequency:45Hz~65Hz,Resolution:0.01Hz. 7. Output waveform distortion:Both voltage and current
Overview: The RT6303B Multi-function Three Phase Energy Meter Test Instrument adopts internationally advanced new-generation digital power source technology, integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way. The Multi-function three phase energy meter test instrument¡¯s power source uses MCU single chip microprocessor as its core technology and adopts various techniques as digital synthesis, digital frequency modulation, digital amplitude modulation, digital phase-shifting, pulse width modulation and so on to bring you such important features as high reliability and good load characteristics. Its more humane and intelligent meter calibration software makes it possible for an ordinary, heavy and boring calibration to be carried out more easily and efficiently. Technical Parameters: 1. Accuracy class: 0.1/0.05 2. Reference standard energy meter: Three phase wide-measurement range standard energy meter, Accuracy class:0.1/0.05 3. Output voltage: 3* 57.7/100/220/380V Y/¡÷,0~120%Adjustment fineness:0.01% full range, adjustable phase by phase 4. Output current: 3* 0.1~100A(200A also available),0~120%Adjustment fineness:0.0001A(minimum),adjustable phase by phase 5. Phase shift:0~360¡ãAdjustment fineness:0.01¡ã,adjustable phase by phase 6. Frequency:45Hz~65Hz,Adjustment fineness:0.01Hz 7. Output waveform distortion: Both voltage and current
Application: HV test shielding room (faraday cage) are Widely used in power cable, transformer, transformer switch, transformer substation and other High voltage levels of partial discharge test or impulse test. For HV testing shielding room, as a HV test place, it should has good electromagnetic shielding condition. And its electromagnetic compatibility always is of great importance. Firstly, it should restrict electromagnetic wave into inside shielding room caused by discharge when making HV test to weakening interfere to outside, especially on electronic and communication system. Secondly, it should prevent outer electromagnetic wave intruding into shielding room to cause measurement error of partial discharge and wireless. Thirdly, it should reduces open circuit voltage and closed current to restrain common-mode interference so that to avoid equipment damage and to improve accuracy of impulse measurement. For GIS HV test shielding room, design area is 500 m2ï¼?Length 25mã??Width 20m). From provided information , we find that steel structure have been completed already with one set of 20T crane indoor, crane supporting corbel also completed, the height is 17.9m from ground to upper part of corbel. Main door height 13m,width 10m, locates at downward of the west side, the door open direction towards to north . According to ILJIN drawing, three side of structure column has already, but western structure column still missing yet. however, as the main door will be located in this side, the western side also should have steel structure , and this structure position still should be unified considered with main door installation. We will be able to submit suggested design diagram with position & size of this structure column for reference. in order to save construction cost, the construction engineering will be carried out by ILJIN team.
Scratch Grinding Tester Automobile line inspection equipment Wire and Cable Detection Equipment It is applicable for assessing the scratch-resistant performance of automobile wire insulation with external forces in line with the requirements of GB/T12528-2008. Main parameters: 1. The scratch grinding device exercises in two directions along wire axes with a stroke above 10mm 2. Exercise frequency: 50~60 cycles/min 3. Minimum distance between test points and test point and test sample end: >10mm; rotation angle of test sample: 90° 4. Length of test sample: Test sample which is about 750mm is firmly fixed to a steel anvil 5. Weight: 400, 700, 1000g (weights applied to scratching needle) 6. Function: The device will stop when the scratching needle grinds through insulation and comes into contact with conductor
Resistance Test Instrument Supplier ZY9733 and ZY9734 digital desk type low current resistance measuring meters are suitable for units concerned to measure the DC resistance of various components and parts with certain limitations on current, such as platinum resistor, coppery thermal resistor, PTC ceramics, thermistor and various wire rods, etc. 1. Key features 1.1 It adopts a large green LED to display measured value, which is striking and clear. It also adopts the four-terminal resistance measurement method to eliminate the impact of conductor resistance, and the measurement accuracy is high. 1.2 There are a variety of specifications, and each specification has four scales to meet the measurement requirements of different users. 1.3 The test current is lower than similar equipment, which effectively prevents the impact of components and parts on resistance. 1.4 ZY9734 type has a RS-232 serial data output interface to facilitate the connection to computer. 1.5 It adopts a novel plastic shell and can changes the inclined angle between the device and table by adjusting the handle position, so as to determine the suitable panel observation angle. It has a well-designed appearance and is easy to use. 2. Main technical indicators Temperature: Reference conditions: 20±5; nominal condition: 5~35 Relative humidity: Reference conditions: 40~60%; nominal condition: 25%~75% Power source: AC 220V±10%, 50Hz, power consumption: About 5VA.