Product Description Probe Mechanical& Electronical Specification Pitch 1.00mm[ 0.039in] Working Stroke 4.25mm[ 0.167in] Full Stroke 6.35mm[ 0.250in] Spring Force 1N 1.5N Resistance Max.50mOhm Current 3Amp Operated Temperature -40~125�°C Drilling Hole Size 0.780-0.805mm [.0307-.0317in] Probe Material and Treatment Plunger SK4 or BeCu/ Au Plated Spring Music Wire/ Au Plated Tube Bronze/ Au Plated
AC to DC converter battery charger 150-1000VDC rectifier 120KW power supply Product Introductionï¼? SANDI AC/DC Charger is specially developed for DC chargers. It has high efficiency, high power factor, high power density, high reliability advantage. AC input 3 phase, DC output voltage range from 150 to 1000VDC can be set, compliant with CE safety requirements, EMC standard EN61000-6-3 and EN61000-6-1 Class A, it is an advanced international level charger. Unique function High efficiency over the full load range, full load efficiency greater than 95% Wide output voltage range, 150-1000VDC, suitable for a wide range of Lithium or lead acid battery 5-inch LCD touch screen, easy to operate Flexible application, charging voltage, charging current, charging time, timing charging can be set by LCD screen, easy to operate Main featuresï¼? Powerful protection, overheating, short circuit, overload, overvoltage, undervoltage, etc. Wide input voltage range: 260~ 530Vac, adaptable to various power grid environments Three-phase AC input without neutral wire: Simplifies system design, eliminates the risk of excessive neutral current, and reduces system costs. Dual DSP design, achieve the full digital control, less components means high reliability Wide input voltage range, allows operation in most poor grid conditions Battery anti backflow: effectively protects the battery while ensuring reliable and safe operation of the system Input, output have protective circuit breaker switch Module adopts hot pluggable design, which is convenient for maintenance. RS485 interface (Optional)
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C
100% OPEN&SHORT&MISS WIRE TEST CONDUCTOR RESISTANCE: 0.5FT-7FT CONDUCTOR RESISTANCE:2 Ohm/PCS 14FT-50FT CONDUCTOR RESISTANCE:3 Ohm/PCS TEST INSTRUMENT:CCL-W-IO064 INSULATION RESISTANCE: 5M Ohm(MIN) HI-POT:300V DC Application: RJ45 Connectors. The shielding layer made of aluminium foil allows to minimize crosstalk and interference with the external environment
The special explosion-proof cable is composed of conductor, insulation, high-strength braided explosion-proof reinforcement layer, explosion-proof armor layer and antistatic outer sheath. According to the different needs of customers, the insulation layer is divided into inorganic mineral insulation, rubber insulation and plastic insulation. Under the protection of the explosion-proof reinforced layer and explosion-proof armor, the special explosion-proof cable can withstand the destructive force of 55 kg of TNT explosives within a certain distance. At the same time, the anti-static outer sheath can effectively guide the static electricity generated by the friction between the cable and the non-insulator, prevent the fire, explosion and other safety accidents caused by static electricity in military facilities, and perfectly solve the technical problem that the "cable static bundle" is easy to detonate. The special explosion-proof cable also solves the current national defense combat readiness facilities, such as ammunition depots, hangars, military ports, caverns, military and civilian airports, tunnels, military exercise bases, large-scale power, chemical, coal, subway hazardous chemical wharf and other electrical equipment facilities Safety issues of explosion-proof system or unit power transmission. Inorganic mineral insulated explosion-proof cables also have: low-smoke, halogen-free, flame-retardant, low-toxicity, fire-proof and other combustion characteristics, and have passed the most demanding C, W, Z and BS8491 fire tests in the British BS6387. At the same time, the cable has good flexibility, Features such as strong compression resistance and long manufacturing length. Special explosion-proof cable is suitable for ammunition depots, hangars, military ports, caverns, military and civil airports, tunnels, military exercise bases, large electric power, chemical, coal mine, subway dangerous wharves
The function of a capacitor in a fan is to store electrostatic energy in an electric field and where possible, to supply this energy to the circuit. The role of a capacitor in a fan is to prevent a dangerous failure of the circuit, they allow the AC to move but block the flow of DC. A condenser, also known as a capacitor, is used in a fan to help regulate the electrical current flowing through the mot. The function of the condenser in a refrigeration system is to transfer heat from the refrigerant to another medium, such as air and/or water. By rejecting heat, the gaseous refrigerant condenses to liquid inside the condenser. A condenser is an essential component within any HVAC system. Its purpose is to take in high-pressure refrigerant gas, emitted by the compressor, and convert it into liquid state. The refrigerant is cooled and then condenses at a virtually constant temperature and pressure. A capacitor can help a fan motor to run at a higher speed by helping to regulate the current flowing through the motor. A capacitor is connected to the start winding in a Fan. In low power induction motor like fan it is left connected permanently, so as the capacitor ages speed of Fan reduces.
CORE COLOUR: As per IS: 694:2010 - 3-CORE - Red, Yellow, Blue / 4-CORE - Red, Yellow, Blue, Black, As per IEC:60227 - 3CORE -Blue, Brown, Black / 4CORE -Blue, Brown, Black, Grey or Yellow/Green, COPPER: EC flexible copper generally conforms to IEC 60228, DIN VDE 0295, IS 8131, INSULATION: Special grade of PVC for inner and outer As Per IS:5831, TECHNICAL DATA: WORKING TEMPRATURE : MAX +70�° C, VOLTAGE RANGE : UP TO 1100 V, TEST VOLTAGE : 3000 V, MINIMUM BENDING : 6 X cable diameter, APPLICATION: Drinking Water Supply Pumps, Submersible motor power supply, SPECIAL FEATURES: Excellent mechanical & electrical properties, Excellent resistant to moisture, abrasion, grace, oil. PACKING: 500/1000 meters on drums.
CORE COLOUR As per IS: 694:2010 - 2-CORE - Red, Black / 3-CORE - Red, Yellow, Blue / 4-CORE - Red, Yellow, Blue, Black As per IEC:60227 - 33CORE -Blue, Brown, Black or Yellow/ Green / 4CORE -Blue, Brown, Black, Grey or Yellow/Green COPPER EC flexible copper generally conforms to IEC 60228, DIN VDE 0295, IS 8131 INSULATION AND OUTER Special grade of PVC for inner and outer As Per IS:5831 TECHNICAL DATA WORKING TEMPRATURE : MAX +70�° C VOLTAGE RANGE : UP TO 1100 V TEST VOLTAGE : 3000 V MINIMUM BENDING : 6 X cable diameter APPLICATION Drinking Water Supply Pumps, Submersible motor power supply, appliances, control panels, machinery, and industries of every nature. PACKING 500/1000 meters on drums.