Product Description Probe Mechanical& Electronical Specification Pitch 1.00mm[ 0.039in] Working Stroke 4.25mm[ 0.167in] Full Stroke 6.35mm[ 0.250in] Spring Force 1N 1.5N Resistance Max.50mOhm Current 3Amp Operated Temperature -40~125�°C Drilling Hole Size 0.780-0.805mm [.0307-.0317in] Probe Material and Treatment Plunger SK4 or BeCu/ Au Plated Spring Music Wire/ Au Plated Tube Bronze/ Au Plated
Application Use for control and connecting cable on data transmission within building management system, speaker audio system and control measurement. Suitable for use in dry and damp environment. Cable Structure & Features Conductor Material : Tinned copper stranded Insulation : Semi-Rigid PVC Drain Wire : Tinned copper stranded Shielding : Aluminium foil laminated screen Outer Sheath ; PVC Sheath Colour : black or gray Technical Data Standard : UL Style 2464 Approvals : UL apporoved Rated Voltage : 300V Testing Voltage : 1500V Flame Retardant : VW-1 Insulation Resistance : Min 20Mx km Min. Bending Radius : 10 x cable diameter Operating Temp. : -30C / +80C
The special explosion-proof cable is composed of conductor, insulation, high-strength braided explosion-proof reinforcement layer, explosion-proof armor layer and antistatic outer sheath. According to the different needs of customers, the insulation layer is divided into inorganic mineral insulation, rubber insulation and plastic insulation. Under the protection of the explosion-proof reinforced layer and explosion-proof armor, the special explosion-proof cable can withstand the destructive force of 55 kg of TNT explosives within a certain distance. At the same time, the anti-static outer sheath can effectively guide the static electricity generated by the friction between the cable and the non-insulator, prevent the fire, explosion and other safety accidents caused by static electricity in military facilities, and perfectly solve the technical problem that the "cable static bundle" is easy to detonate. The special explosion-proof cable also solves the current national defense combat readiness facilities, such as ammunition depots, hangars, military ports, caverns, military and civilian airports, tunnels, military exercise bases, large-scale power, chemical, coal, subway hazardous chemical wharf and other electrical equipment facilities Safety issues of explosion-proof system or unit power transmission. Inorganic mineral insulated explosion-proof cables also have: low-smoke, halogen-free, flame-retardant, low-toxicity, fire-proof and other combustion characteristics, and have passed the most demanding C, W, Z and BS8491 fire tests in the British BS6387. At the same time, the cable has good flexibility, Features such as strong compression resistance and long manufacturing length. Special explosion-proof cable is suitable for ammunition depots, hangars, military ports, caverns, military and civil airports, tunnels, military exercise bases, large electric power, chemical, coal mine, subway dangerous wharves
Supplier: Flanges: slip on, welding neck/long welding neck, socket welding, threaded, blind/bossed blind, orifice, special flanges as per customer drawing, fasteners (socket head, set screw, counter sunk, button head, hexagonal head bolts & screws, hex nuts) washers, dowel pins (parallel pins, taper, knurled pin, spiral pin, grooved, clevis), guided bushing, friction grip bolt, cold forged components, gear shaft, spline shaft, kick shaft, ball pins, ball rods, shaft for alternator or stators, brake scam, piston pin, material grades like alloy steel 8.8, 10.9, 12.9, 45h, 14.9, 14k, stainless steel a1, a2, a3 & a4, 204, 410, 416, 431, 420, brass, aluminum v65/2024, titanium bt16, gears, timing belts, bearings, gaskets, o rings, seals, keys, grinding wheels and abrasive paper, welding rods, hexagonal wrench, a4 papers reams, tapes, corrugated sheets, boxes, cnc, vmc machine precision component(turning, milling, moulding & fixtures tools).
Electrical Characteristics - Rated Voltage : 0.6/1 kV AC - Rated DC Voltage : 1.5 kV - Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor, non earthen system, circuit not under load) - Maximum Permitted AC Voltage : 1 KV - Working Voltage : DC 1000 V - Spark Test : 6000 V. ac (8400 Vdc) - Voltage Withstand : 6500 V as per EN50395 for 5 min - Ampacity : According to requirements for cables for PV systems Technical Data - Ambient Temperature : -40C +90C - Minimum Bending Radius : 5 x OD (fixed), 15 x OD (occasional flexing) - Flame retardant according to IEC 60332-1-2 - Low smoke emission < 20% as per ASTM D-2843 - Halogen free according to EN 50267-2-1/-2, IEC 60754-2 - Maximum Temperature at Conductor : 120C (20000h) - Short Circuit Temperature : 200�?�°C (at conductor max. 5sec) - Thermal Endurance Test : According to EN 60216-2 (temperature index +120C) - High Temperature Pressure : Test according to EN 60811-3-1 - Excellent mechanical and electrical properties. - UV resistance & OZONE resistance - Flexibility & suitability for fast & easy installation Cable Standard EN 50618 Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Electrolytic fine Tinned copper class-5 conductor according to IEC 60228 Insulation XLPO (Crosslinked Halogen Free & Flame Retardant) Sheath XLPO (Crosslinked Halogen Free & Flame Retardant) Color Red, Black and also available black color with red lining. Application For Solar Panel, Solar Power Plant, Solar Pump Installation.
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Cable Standard Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistant to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -25�?�°C to 70�?�°C Operating Temp : -20�?�°C to max. +90�?�°C Nominal Voltage : 450/750 V Test Voltage : 2500V Min. Bending Radius : 6 x cable Diameter Flame propagation : Flame retardant test as per IEC 60332-1-2 Standard Packing Coils 100, 200,500 and 1000m Conductor Flexible bare Class 5 copper conductor according to DIN VDE 0295,IEC 60228 Insulation Rubber Type El-4 to VDE 0282 Part-1 Sheath Neoprene Jacket Rubber Type EM-2 Color White, Black, Blue or as per customer order Core Identification 1 Core - Black 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey 5 Core - Yellow/Green, Blue, Brown, Black and Grey Application H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites
Cable Standard Generally conforms to IS 694:2010, IEC60228, BS 6004 Silent Features - Special heat resistant insulation - Higher current carrying capacity - Fine copper wires - Highly thermal stable insulation - High electrical conductivity - Long Life - Excellent mechanical & electrical properties Technical Data Operating Temp : -10�?�°C to max.+90�?�°C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Standard Packing Coils 100, 200, 500 and 1000m. Conductor Bare Copper class1 or class-2 as per IS:8130, IEC 60228 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Black, Green, Yellow/green or as per customer requirement Application Neskeb - Earth : Installation in surface mounted or embedded conduits, or similar closed systems
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.